微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

4.1 Classification of insulation relative to flexibility or rigidity is useful in establishing installation and application characteristics.1.1 These test methods cover the procedures for the classification of mineral fiber insulation as flexible, resilient flexible, semirigid, or rigid.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 It is possible that insulating blocks or boards that are not true or square will not fit properly. It is possible that extra labor will be required to obtain proper fit and that this could affect the product performance as well as the appearance of the finished installation.4.2 This test method provides terminology and describes locations for obtaining consistent measurements of trueness and squareness of blocks and boards.1.1 This test method covers locations for measuring the trueness and squareness of rigid block/board thermal insulation. This test method does not purport to address the variability in board thickness. Thickness is addressed in other ASTM standards.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

The resistance of corrugated fiberboard shipping containers to damage by moisture is improved by wax treatment, and a common practice involves a light wax saturation applied to the medium and facings, followed by a curtain coating or roll coating operation applying wax to the surface. The functional performance of the board is dependent upon the amount of wax deposited in each operation.5.1.1 For the wax impregnation within the facing, the principal concern is with the weight of wax used relative to the weight of paperboard present, that is, the weight percent loading or pickup. This method measures that loading and assumes that the loading is distributed uniformly throughout the facing. However, the method does not provide a measure of the weight of impregnating wax per unit area, since not all of the facing fibers are utilized in the testing.5.1.2 For the wax coating the principal concern is in the weight of wax present on the surface per unit area. This method measures the amount of material applied, and assumes that the major portion of molten coating applied will congeal and remain on the surface, without undue migration into the fibrous structure of the medium.Note 2—In a typical curtain coating application, a portion of the coating will partially migrate into and become embedded in the fibers of the facing to the extent of about 10 % of the coating applied.5.1.3 These procedures involve extractions of designated sections of the paperboard and determination of the extractable material reported as wax. This assumes that the nonwax extractables in the paperboard substrate are in negligible amount (for example, about 0.2 weight %).Note 3—If the application of a correction for nonwax extractables is desired, a suitable unwaxed board specimen may be extracted and appropriate calculations made.1.1 This test method covers the determination of the weight of wax that has been applied for coating of corrugated board, and the amount of impregnating (saturating) wax in the same facing.1.2 This test method is especially applicable to board that has a coated surface and also contains wax saturation within the facing structure. Note 1 - The amount of surface wax on board that may or may not contain impregnating (saturating) wax within its structure may be determined alternatively by Test Method D 3521. If it is known that the specimen has coating wax only, with no internal impregnating wax, the total coating wax applied may be determined by Test Method D 3344.<>This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
AS 1974-1976 Drawing board dimensions 被代替 发布日期 :  1970-01-01 实施日期 : 

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

4.1 The procedures described in this practice are intended to be used to establish design capacity (both strength and stiffness) values based on testing of OSB that, at a minimum, satisfies the relevant performance requirements of PS 2.4.2 Review and reassessment of values derived from this practice shall be conducted on a periodic basis. If a change is found to be significant, retesting or reevaluation, or both, in accordance with the procedures of this practice shall be considered.1.1 This practice covers the basis for code recognition of design capacities for OSB structural-use panels. Procedures are provided to establish or re-evaluate design capacities for OSB structural-use panels in flatwise and axial applications. Design capacities for OSB structural-use panels in edgewise applications, such as rim board, are outside the scope of this standard. Procedures for sampling and testing are also provided. Design values stated as capacity per unit dimension are to be regarded as standard. Design capacities developed in accordance with this practice are applicable to panels intended for use in dry in-service conditions.NOTE 1: This practice is based on ICC-ES Acceptance Criteria AC-182. Relative to the scope of AC-182, this practice is limited to OSB panels.NOTE 2: While this practice makes reference to PS 2, this practice applies similarly to products certified to other standards such as CAN/CSA O325.NOTE 3: OSB produced under PS 2 is rated with the “Exposure 1” bond classification. Exposure 1 panels covered by PS 2 are intended for dry use applications where the in-service equilibrium moisture content conditions are expected to be less than 16 %. Exposure 1 panels are intended to resist the effects of moisture due to construction delays, or other conditions of similar severity. Guidelines on use of OSB are available from manufacturers and qualified agencies.NOTE 4: PS 2-10 replaced the use of nominal thicknesses with a classification term known as Performance Category, which is defined in PS 2 as “A panel designation related to the panel thickness range that is linked to the nominal panel thickness designations used in the International Building Code (IBC) and International Residential Code (IRC).” Therefore, the PS 2 Performance Category should be considered equivalent to the term “nominal thickness” used within this standard.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers the manufacture, testing, and physical requirements of two classes of asphalt based protection board used for protecting the integrity of below grade or below wearing surface waterproofing. Class A is made with asphalt saturated organic felt on the bottom and a coated or saturated non-woven glass felt on top, while Class B is made with glass fabrics both top and bottom. The boards shall be sampled for testing, and each class shall conform accordingly to specified individual values of the following physical properties: nominal thickness; puncture strength; water absorption; asphalt content; and resistance to decay.1.1 This specification covers an asphalt based protection board used for protecting the integrity of below grade or below wearing surface waterproofing. The protection board protects the waterproofing system from backfill, surfacing, construction activities, and weathering conditions prior to backfilling or applying surfacing.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
ASTM C209-20 Standard Test Methods for Cellulosic Fiber Insulating Board Active 发布日期 :  1970-01-01 实施日期 : 

4.1 The test methods contained in this document are intended for cellulosic fiber insulating board as described in Specification C208. These test methods examine mechanical, physical and thermal properties, properties related to water absorption and water vapor exposure, and flammability related properties.4.2 The results of these tests are suitable to describe the performance of insulating board and are also suitable for use in material specifications.NOTE 1: Committee C-16 is in the process of splitting this document into discrete test methods categorized by the nature of the test methods.1.1 These test methods cover those insulation products in specified Specification C208. The requirements for the products’ physical properties are specified in Specification C208. The methods for the general insulation products’ physical properties are given as follows:  SectionThickness  7Size of Finished Board  8Thermal Conductivity  9Transverse Strength 10Deflection at Specified Minimum Load 11Tensile Strength Parallel to Surface 12Tensile Strength Perpendicular to Surface 13Water Absorption 14Linear Expansion 15Water Vapor Transmission 16Flame Spread Index 17Moisture Content and Density 18Compressive Strength 191.2 Reference is provided to an established source for nomenclature and definitions.1.3 Several of the test methods contained in this document are referenced by material specifications other than cellulosic fiber insulating board. These include mineral fiber, perlite, polyisocyanurate, polystyrene and phenolic materials.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM C1395/C1395M-04e1 Specification for Gypsum Ceiling Board (Withdrawn 2005) Withdrawn, Replaced 发布日期 :  1970-01-01 实施日期 : 

1.1 This specification covers 1/2 in. [12.7 mm] thick gypsum ceiling board designed for use on interior ceilings with framing spaced not more than 24 in. [610 mm] on center and that affords a surface suitable to receive water-based texture and other decoration. This product is also suitable for use on interior walls.Note 1—Specification C 840 contains application procedures for gypsum ceiling board.1.2 The values stated in either inch-pound units or SI (metric) are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shall not be combined.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
47 条记录,每页 10 条,当前第 2 / 5 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页