微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读
C22.2 NO. 0.5-1982 (R2003) Threaded Conduit Entries 现行 发布日期 :  1970-01-01 实施日期 : 

1. Scope 1.1 This Standard applies to equipment for installation and use in accordance with the Rules of the Canadian Electrical Code, Part I, other than conduit couplings. 1.2 This Standard includes basic construction and inspection requirements

定价: 455元 / 折扣价: 387

在线阅读 收 藏

3.1 Underground electrical and communication conduit should be impervious to groundwater in order to prevent damage to conductors and utility vaults. The bladder test described in this test method may be used to qualify potential gasketed conduit systems by indicating whether the joint system will prevent water infiltration.3.2 This test method can be used to qualify joints for plastic underground conduits using flexible elastomeric seals. However, it should not be assumed that a joint system that passes this test method will be able to seal under cases of misinstallation or abuse, or both.3.3 This test method covers all of the following gasketed conduit types: encased burial (EB) excluding EB20, direct burial (DB), telecommunications, cable television, and Schedule 40 conduit and Schedule 80 conduit. Trade sizes covered are 2-in. nominal size and larger. (See UL 651; NEMA TC-2, TC-6, and TC 8; and Specification F512.)3.4 This test method also covers fittings that are intended for use with the conduit types described in 3.3 and which use flexible elastomeric seals.1.1 This test method covers the determination of the water infiltration resistance of gasketed plastic underground conduit joints using a pressurized water bladder apparatus.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
ASTM C875-98(2014) Standard Specification for Asbestos-Cement Conduit (Withdrawn 2019) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

This specification covers asbestos-cement conduit for use in electric-power systems and communication systems, serviced in both underground and exposed conditions. The classes of conduit shall be as follows: Class B, intended for use encased in concrete after installation; and Class C, intended for use without concrete encasement, or for exposed services. The conduits shall also be classified into two types (I and II) according to uncombined calcium hydroxide content. Materials shall conform to specified mechanical requirements such as flexural strength and crushing strength.1.1 This specification covers asbestos-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions.1.2 The values stated in SI units are to be regarded as the standard. The values stated in parentheses are provided for information only.1.3 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”21.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 1.3 for specific hazard warning.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This guide describes the design, selection considerations, and installation procedures for the placement of polyethylene pipe or conduit below ground using maxi-horizontal directional drilling equipment. The pipes or conduits may be used for various applications including telecommunications, electric power, natural gas, petroleum, water lines, sewer lines, or other fluid transport. Horizontal directional drilling is a form of trenchless technology. The equipment and procedures are intended to minimize surface damage, restoration requirements, and disruption of vehicular or maritime traffic with little or no interruption of other existing lines or services. Mini-horizontal directional drilling (min-HDD) is typically used for the relatively shorter distances and smaller diameter pipes associated with local utility distribution lines. In comparison, maxihorizontal directional drilling (maxi-HDD) is typically used for longer distances and larger diameter pipes common in major river crossings. Applications that are intermediate to the mini-HDD or maxi-HDD categories may utilize appropriate “medi” equipment of intermediate size and capabilities. In such cases, the design guidelines and installation practices would follow those described for the mini- or maxi-HDD categories, as judged to be most suitable for each situation.1.1 This guide describes the design, selection considerations, and installation procedures for the placement of polyethylene (PE) pipe or conduit below ground using maxi-horizontal directional drilling equipment. The pipes or conduits may be used for various applications including telecommunications, electric power, natural gas, petroleum, water lines, sewer lines, or other fluid transport.1.2 Horizontal directional drilling is a form of trenchless technology. The equipment and procedures are intended to minimize surface damage, restoration requirements, and disruption of vehicular or maritime traffic with little or no interruption of other existing lines or services. Mini-horizontal directional drilling (mini-HDD) is typically used for the relatively shorter distances and smaller diameter pipes associated with local utility distribution lines. In comparison, maxi-horizontal directional drilling (maxi-HDD) is typically used for longer distances and larger diameter pipes common in major river crossings. Applications that are intermediate to the mini-HDD or maxi-HDD categories may utilize appropriate “medi” equipment of intermediate size and capabilities. In such cases, the design guidelines and installation practices would follow those described for the mini- or maxi-HDD categories, as judged to be most suitable for each situation.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Section 6 contains general safety information related to the use of maxi-horizontal directional drilling equipment.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

9.1 The requirements of this specification are intended to provide extruded PVC profile strip suitable for the field fabrication of spirally wound liner pipe for the rehabilitation of existing pipelines and conduits conveying sewage, process flow, and storm water under gravity flowconditions.NOTE 3: Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority since chemicals not commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.AbstractThis specification covers the requirements and test methods for materials, dimensions, workmanship, stiffness factor, extrusion quality, and test procedures for extruded poly(vinyl chloride) (PVC) profile strips used for machine-made field fabrication of spirally wound pipe liners in the rehabilitation of a variety of existing pipelines and conduits including sanitary sewers, storm water sewers, process flow piping, and non-circular pipelines (such as arched or oval shapes and rectangular shapes) under gravity flow conditions. Certification, packaging, and product marking for quality assurance are also considered.1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, stiffness factor, extrusion quality, and a form of marking for extruded poly(vinyl chloride) (PVC) profile strips used for machine made field fabrication of spirally wound pipe liners in the rehabilitation of a variety of gravity applications such as sanitary sewers, storm sewers, and process piping in diameters of 6 to 180 in. and for similar sizes of non-circular pipelines such as arched or oval shapes and rectangular shapes.1.2 Profile strip produced to this specification is for use in field fabrication of spirally wound liner pipes in nonpressure sewer and conduit rehabilitation, where the spirally wound liner pipe is expanded until it presses against the interior surface of the existing sewer or conduit, or, alternatively, where the spirally wound liner pipe is inserted as a fixed diameter into the existing sewer or conduit and the annular space between the liner pipe and the existing sewer or conduit is grouted.1.3 This specification includes extruded profile strips made only from materials specified in 5.1.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The following precautionary caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 The assembly force of a conduit joining system is one measure of the ease of which the conduit system can be assembled and installed in the field. This test method provides a means by which to quantify the assembly force of gasketed conduit joining systems. The results of the testing can be used to compare and categorize the assembly force of different designs of gasketed conduit joining systems.5.2 This test method is not intended for use as a quality control test.5.3 This test method can be used for comparison of gasketed conduit joining systems on the basis of assembly force. No information about joint sealing performance can be obtained from the use of this test method.5.4 This test method covers all plastic conduit with push-on joints that use flexible elastomeric gaskets located in the bell to provide the joint seal.5.5 This test method is also applicable to all fittings that are fabricated from conduit covered in 5.4 and that utilize the same type of push-on joints as the conduit covered in 5.4, and that are intended for use with the conduit types described in 5.4. For purposes of this test method, assembly force data obtained from the testing of the conduit that is the parent stock of a fitting shall apply to the fitting also.1.1 This test method covers the determination of the relative force required to assemble plastic underground conduit joints that use flexible elastomeric seals located in the bell.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers non-asbestos fiber-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions. The classes of conduit shall be as follows: Class B which is intended for use encased in concrete after installation and Class B which is intended for use without concrete encasement, or for exposed services. The types of conduit shall be known as Type I and Type II corresponding to the chemical requirements specified. Type I is to be used where nonaggressive water and soil of moderate surface content are expected to come in contact with the conduit. Type II is to be used where moderately aggressive water or water and soil of high sulfate content, or both, are expected to come in contact with the conduit. Fiber-cement conduit shall be composed of an intimate mixture of an inorganic hydraulic binder or a calcium silicate binder formed by the chemical reaction of a siliceous material and a calcareous material reinforced by organic fibers, inorganic non-asbestos fibers, or both. Process aids, fillers and pigments which are compatible with fiber-reinforced cement are not prohibited from being added. All material shall be of laminar construction formed under pressure to a homogeneous structure and cured to meet the physical and chemical requirements. Mechanical properties like flexural strength and crushing strength of the conduit shall be determined.1.1 This specification covers non-asbestos fiber-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This PDF includes Update No. 1 1 Scope 1.1 This Standard describes general requirements, apparatus, and test methods to be used in carrying out applicable tests and calculations for rigid nonmetallic conduits, elbows, bends, and associated fittings

定价: 910元 / 折扣价: 774

在线阅读 收 藏
C22.2 NO. 211.1-M1984 (R2003) Rigid Types EB1 and DB2/ES2 PVC Conduit 现行 发布日期 :  1970-01-01 实施日期 : 

This PDF includes GI #2 and #3. 1. Scope 1.1 This Standard applies to nonmetallic conduit of rigid PVC, type EB1 for encasement in concrete or masonry and type DB2/ES2 for direct burial or encasement in concrete or masonry, and their associated fit

定价: 455元 / 折扣价: 387

在线阅读 收 藏
C22.2 NO. 211.2-M1984 (R2003) Rigid PVC (Unplasticized) Conduit 现行 发布日期 :  1970-01-01 实施日期 : 

1. Scope 1.1 This Standard applies to rigid unplasticized poly(vinyl chloride) conduit, elbows, bends, and couplings intended for use at a continuous operating temperature of 75°C for the installation of wires and cables in accordance with the Rules o

定价: 455元 / 折扣价: 387

在线阅读 收 藏

定价: 3367元 / 折扣价: 2862

在线阅读 收 藏

This PDF includes GI #2. 1. Scope 1.1 This Standard specifies the requirements for halogen-free reinforced thermosetting resin conduit (RTRC), and associated fittings for installation and use in accordance with the Rules of the Canadian Electrical

定价: 1775元 / 折扣价: 1509

在线阅读 收 藏

Environmental performance test values for smooth-wall, coilable, medium density and high density polyethylene (MDPE and HDPE) conduit (duct) for preassembled wire and cable may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications. 1.1 These test methods cover procedures for determining the environmental performance properties of smooth-wall, coilable, medium-density and high-density polyethylene (MDPE and HDPE) conduit (duct) for preassembled wire and cable. 1.2 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

定价: 3595元 / 折扣价: 3056

在线阅读 收 藏

This specification covers the material, dimensional, and requirements and corresponding test methods for folded poly(vinyl chloride) (PVC) pipes suitable for the rehabilitation of existing nonpressure sewers and conduits, wherein the folded PVC pipe is inserted into, and then expanded to conform to the wall of, the original conduit forming a new pipe-within-a-pipe structure. This specification does not include pipes manufactured from reprocessed, recycled, or reclaimed PVC. Appropriately sampled specimens shall be tested, and shall thereby conform accordingly to specified requirements for flattening resistance, impact strength, stiffness, extrusion quality by acetone immersion and heat reversion, flexural modulus of elasticity, and rounded pipe diameter and wall thickness.1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded poly(vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.1.2 Folded PVC pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is inserted into and then expanded to conform to the wall of the original conduit forming a new pipe-within-a-pipe.NOTE 1: For installation procedures and engineering design considerations refer to Practice F1947.1.3 This specification includes folded PVC pipe made only from materials specified in Section 6. This specification does not include folded pipe manufactured from reprocessed, recycled, or reclaimed PVC.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The following precautionary statement pertains to the test method portion only, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
33 条记录,每页 15 条,当前第 1 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页