微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This guide provides a recommended list of selected ship structure details for use in ship construction. Structural details which have failed in service and are not recommended for use in ship construction are included as well. This guide is intended to convey the lessons learned on different configurations of ship structure details, not the dimensions, thickness, or construction methods which would result from structural calculations. Details are shown for the ten families of structural details, which are: beam brackets, clearance cut-outs, gunwale connections, miscellaneous cut-outs, non-tight collars, panel stiffeners, stanchion ends, stiffener ends, tight collars, and tripping brackets. Evaluation of details is based on in-service experience as described in "Design Guide for Structural Details". Data for over 400 details is summarized and rated by observed relative successful performance. Each of the ten families of details includes configurations with no signs of failures. The details without failures within each family group are shown in descending order of numbers observed. Those details with failures are shown in ascending order of failures (percentages are indicated for each). Thus the first detail shown in each family group has the best observed service performance and is most highly recommended while the last has the highest failure rate and therefore least desirable. The details provide guidance in the selection of structural detail configurations in future design and repair of such details.1.1 This guide provides a recommended list of selected ship structure details for use in ship construction.1.2 Structural details which have failed in service and are not recommended for use in ship construction are included as well.1.3 This guide is intended to convey the lessons learned on different configurations of ship structure details, not the dimensions, thickness, or construction methods which would result from structural calculations.41.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

This guide illustrates general details for typical conditions that may be encountered on an EPDM sheet roofing system.This guide does not address all requirements associated with the installation of EPDM membrane flashing, such as membrane cleaning and surface preparation, fastener spacing, adhesive application and other seaming requirements which may vary by membrane system supplier.Insulation, fastener types, protection mats, stone ballast, pavers, and requirements for perimeter attachment are not covered by this guide. The designer shall review the project requirements and consult the membrane system supplier, building insurer, and local building codes for specific requirements.1.1 This guide covers the design of details for typical conditions encountered in new ballasted, mechanically attached or fully adhered ethylene propylene diene terpolymer (EPDM) sheet roof systems.1.2 This guide illustrates general details for typical conditions that may be encountered on an EPDM sheet roofing system. The guide will assist the designer in preparing details for each specific condition that may occur on a project.1.3 The values stated in SI units are to be regarded as standard. The conventional units given in parentheses are provided for information purposes only.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 This guide illustrates general details for below-grade and plaza waterproofing. It serves as a guide that will enable the designer to prepare complete waterproofing details for each specific condition that occurs on a project.1.1 This guide covers details for typical conditions encountered in adhered sheet waterproofing on below-grade structures and plazas.1.2 This guide does not cover liquid-applied waterproofing.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏
3 条记录,每页 10 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页