微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 605元 / 折扣价: 515

在线阅读 收 藏
AS 1897:2016 Fasteners - Electroplated coatings 现行 发布日期 :  2016-07-19 实施日期 : 

定价: 819元 / 折扣价: 697

在线阅读 收 藏

定价: 819元 / 折扣价: 697 加购物车

在线阅读 收 藏

定价: 819元 / 折扣价: 697 加购物车

在线阅读 收 藏
AS 1275-1985 (R2017)/Amdt 1-1986 Metric screw threads for fasteners 现行 发布日期 :  1986-08-04 实施日期 : 

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏
AS 1559-1986 Fasteners - Bolts, nuts and washers for tower construction 现行 发布日期 :  1986-01-06 实施日期 : 

定价: 689元 / 折扣价: 586 加购物车

在线阅读 收 藏
AS 1275-1972/Cor-1975 Metric screw threads for fasteners 现行 发布日期 :  1975-03-01 实施日期 : 

定价: 0元 / 折扣价: 0

在线阅读 收 藏
AS 1275-1972 Metric screw threads for fasteners 现行 发布日期 :  1972-05-01 实施日期 : 

定价: 689元 / 折扣价: 586

在线阅读 收 藏

5.1 This test method gives a measure of a key property of hook and loop touch fasteners which is of interest to users of such devices. This is a means of determining the resistance to separation when forces are applied parallel to the plane of the fastener.5.2 In the case of a dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens which are as homogenous as possible and which are from a lot of hook and loop of the type in question. The test specimens should then be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student’s t-test and an acceptable probability level chosen by the two parties before the testing began. If a bias is found, either its cause must be found and corrected or the purchaser and the supplier must agree to interpret future test results in the light of the known bias.1.1 This test method measures the shear strength of hook and loop touch (CRE) fasteners using a recording constant rate of extension tensile testing machine.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
ASTM F3393-20e1 Zinc-Flake Coating Systems for Fasteners Active 发布日期 :  1970-01-01 实施日期 : 

1.1 Zinc-flake coating systems are fluid dispersions of zinc-flakes, sometimes with the addition of aluminum flakes, which are non-electrolytically applied to steel substrates. The zinc-flake coating system shall be supplied without hexavalent chromium and can be water based or solvent based systems. Cohesion among the zinc-flakes and adhesion to the steel substrate is achieved through a matrix that is formed during the curing process.1.2 This specification covers the classification, performance, and basic requirements for non-electrolytically applied zinc-flake coatings on unified inch and metric series threaded fasteners with minimum nominal diameters of 0.250 in. for inch series and 6 mm for metric.1.3 This standard is a consolidation and replacement of three ASTM standards: Specifications F1136/F1136M, F2833, and F3019/F3019M.1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

3.1 This test method gives a measure of a key property of hook and loop touch fasteners which is of interest to users of such devices. This is a means of determining the resistance to separation when forces are applied normal to the line of separation of the fastener.3.2 The force registered in a peel test is irregular, and as a consequence, empirical methods have had to be developed to obtain usable values related to peel strength. In spite of the empirical nature of the reported values, it is believed they reflect comparative performance of similar touch fasteners tested and measured in the same way.3.3 Two optional methods of calculation are provided: integrator average and average of five highest peaks. These test methods are not equivalent. Generally, the integrator average will be lower than the average of the five highest peaks.3.4 The highest peaks which reflect the force required to separate a hook and loop closure bear no simple relationship to the average force (integrator average). The average of the five highest peaks better reflect performance but the integrator results may be used to characterize a closure and for quality control purposes. The integrator average is relatively easy to calculate given the proper equipment.3.5 In the case of a dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens which are as homogenous as possible and which are from a lot of hook and loop of the type in question. The test specimens should then be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student’s t-test and an acceptable probability level chosen by the two parties before the testing began. If a bias is found, either its cause must be found and corrected or the purchaser and the supplier must agree to interpret future test results in the light of the known bias.1.1 This test method covers the measurement of the peel strength of hook and loop touch fasteners using a recording constant-rate-of-extension tensile testing machine (CRE).1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This guide covers test procedures for performing accelerated tests to evaluate relative corrosion resistance of various coatings applied to mechanical fasteners. Corrosion mechanisms such as general and crevice corrosion may be evaluated with this method. Test duration may be selected to achieve any desired level of corrosion exposure and provides a frame of reference to determine relative coating resistance to corrosion. Fasteners tightened to a desired tension and subjected to this test procedure may be evaluated to simulate a variety of service conditions. Without large amounts of accumulated field results, it is difficult to relate test duration or the number of test cycles to actual service life for a given application.1.1 This guide covers test procedures for performing accelerated tests to evaluate relative corrosion resistance of various coatings applied to mechanical fasteners. Corrosion mechanisms such as general and crevice corrosion may be evaluated with this method. Test duration may be selected to achieve any desired level of corrosion exposure and provides a frame of reference to determine relative coating resistance to corrosion. Fasteners tightened to a desired tension and subjected to this test procedure may be evaluated to simulate a variety of service conditions. Without large amounts of accumulated field results, it is difficult to relate test duration or the number of test cycles to actual service life for a given application.1.2 This standard is not intended to cover tests of driven fasteners such as nails, staples, screws and lag bolts.1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 The use of this test method can significantly reduce the risk of sudden catastrophic failure of threaded articles and fasteners, below their design strength, due to hydrogen embrittlement.1.1 This test method covers the determination of, on a statistical basis, the probability of the existence of hydrogen embrittlement or degradation in:1.1.1 A batch of barrel electroplated, autocatalytic plated, phosphated, or chemically processed threaded articles or fasteners and1.1.2 A batch of rack plated threaded articles, fasteners, or rod.1.2 Industrial practice for threaded articles, fasteners, and rod has evolved three graduated levels of test exposure to ensure reduced risk of hydrogen embrittlement (see Section 3). These levels have evolved from commercial applications having varying levels of criticality. In essence, they represent the confidence level that is required. They also represent the time that finished goods are held before they can be shipped and used. This time equates to additional cost to the manufacturer that may of necessity be added to the cost of the finished goods.1.3 This test method is applicable to threaded articles, fasteners, and rod made from steel with ≥1000 MPa (with corresponding hardness values of 300 HV10 kgf, 303 HB, or 31 HRc) or surface hardened threaded articles, fasteners, or rod.1.4 This test method shall be carried out after hydrogen embrittlement relief heat treatment in accordance with the requirements of Guide B850. It may also be used for assessing differences in processing solutions, conditions, and techniques. This test method has two main functions: first, when used with a statistical sampling plan it can be used for lot acceptance or rejection, and second, it can be used as a control test to determine the effectiveness of the various processing steps including pre- and post-baking treatments to reduce the mobile hydrogen in the articles, fasteners, or rod. While this test method is capable of indicating those items that are embrittled to the extent defined in Section 3, it does not guarantee complete freedom from embrittlement.1.5 This test method does not relieve the processor from imposing and monitoring suitable process control.1.6 This test method has been coordinated with ISO/DIS 10587 and is technically equivalent. (Warning—Great care should be taken when applying this test method. The heads of embrittled articles, fasteners, or rod may suddenly break off and become flying projectiles capable of causing blindness or other serious injury. This hazard can occur as long as 200 h after the test has started. Hence, shields or other apparatus should be provided to avoid such injury.)Note 1—Test Method F1940 can be used as a process control and verification to prevent hydrogen embrittlement in fasteners covered by this test method.Note 2—The use of inhibitors in acid pickling baths does not necessarily guarantee avoidance of hydrogen embrittlement.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This specification covers nails, spikes, staples, and other fasteners driven by hand tool, power tool, or mechanical device in single or multiple strikes and are positioned by hand, tool, or machine. The driven fasteners are classified as type I: nails (NL); type II: cut nails (CN); type III: spikes (SP); and type IV: staples (ST). Materials shall be tested and the individual types shall conform to the material requirements and physical properties, such as ductility, tensile strength. Protective coating and finishes are also detailed.1.1 This specification covers nails, spikes, staples, and other driven fasteners, as listed in Table 1.NOTE 1: Fastener ductility information is presented in Table 2 and dimensional information in Tables 3–63.1.2 Fasteners described in this specification are driven by hand tool, power tool, or mechanical device in single or multiple strikes and are positioned by hand, tool, or machine.1.3 This specification is applicable in either inch-pounds (F1667) or SI units [F1667M]. Values stated in SI are a mathematical conversion to two significant digits and are shown in brackets [ ].1.4 Fasteners in this specification are sold in bulk (loose) form and are collated for loading into the magazine of an application tool. Other than as covered in Section 9, Workmanship, cohering materials (including, but not limited to, plastic, adhesive bond, paper tape, plastic strip, plastic carrier, wire, etc.) and relative orientation of collated fasteners are not within the scope of this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 918元 / 折扣价: 781 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0

在线阅读 收 藏
50 条记录,每页 15 条,当前第 1 / 4 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页