4.1 This guide is applicable to all water rescue situations. The water situation, weather situation, and size of rescuer, will dictate what type of PFD to utilize.4.2 This guide will assist government agencies; state, local, or regional organizations; fire departments; rescue teams; and others who are responsible for purchasing and equipping personnel who respond to water emergencies.4.3 This guide establishes criteria that shall be considered in the performance, specification, purchase, and acceptance testing of a water rescue PFD.1.1 This guide covers the minimum performance and safety requirements of a water rescue lifejacket/PFD (Personal Flotation Device).1.2 In recognition of many broad and varied applications of such PFD's, many options are included.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 / 折扣价: 438 元 加购物车
4.1 This test method uses specific starting point conditions for the froth flotation response to accomplish the following:4.1.1 Assess responses of one or more coals or blends of coal, and4.1.2 Evaluate and determine froth flotation circuit performance.1.1 This test method covers a laboratory procedure for conducting a single froth flotation test on fine coal (that is, nominal top size of 600 μm (No. 30 U.S.A. Standard Sieve Series) or finer) using a defined set of starting point conditions for the operating variables.1.2 This test method does not completely cover specific procedures for the investigation of flotation kinetics. Such a test is specialized and highly dependent upon the objective of the data.1.3 Since optimum conditions for flotation are usually not found at the specified starting points, suggestions for development of grade/recovery curves are given in Appendix X1. Such a procedure is very case-specific and involves running a series of flotation tests in which some of the operating variables are changed in order to optimize conditions for either yield or grade.1.4 Laboratory flotation results need not be representative of the flotation response of coal in full-scale situations, but a consistent baseline can be established against which full-scale performance can be compared.1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.6 Material Safety Data Sheets (MSDS) for reagents used are to be obtained from suppliers who are to be consulted before work with any chemicals used in this test method.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 590元 / 折扣价: 502 元 加购物车