微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

5.1 Each device has unique flow patterns and turbulence characteristics and may exhibit a wide range of efficiencies as discharge, particle-size distribution, particle density, and flow viscosity (that is, water temperature) changes. The testing procedures described in Section 8 provide a method of measuring the removal efficiency of these devices under a given flow condition, flow viscosity (water temperature), and particle-size distribution and density. Therefore, the results of testing represent the flow, viscosity, and particle-size distribution tested.1.1 This test method concerns measurement of the efficiency of hydrodynamic separators and underground settling devices in removing suspended sediment from simulated stormwater runoff under conditions defined herein. This test method is not intended for use in determining field removal efficiency.1.2 Units tested shall be of a size commonly manufactured, not a scale model. This test method is not intended to address product scaling.1.3 This test method is not for measuring the removal efficiency of filters or the scouring potential of hydrodynamic separators and underground settling devices.1.4 In this test method, only gravity flow operation is addressed—performance of units operating under pressurized conditions is not addressed.1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Each device has unique flow patterns and turbulence characteristics. In addition, each device exhibits a wide range of efficiencies as discharge, particle size, particle density, and flow viscosity (that is, water temperature) change. The testing procedure in Section 7 will help develop the parameters necessary to input into a function that describes the performance of a device under a wide range of application conditions. Specifically, this test standard produces a characteristic curve that describes the hydraulic head-discharge relationship in a hydrodynamic separator over a range of flow rates typical in system operation.1.1 This test method concerns measurement of selected hydraulic characteristics of hydrodynamic separators and underground settling devices critical to their function as stormwater treatment devices.1.2 Units tested shall be of a size commonly manufactured and available for purchase. In order to facilitate testing it is permissible to substitute alternate materials for the housing and structural components of the test units if operational components are at full size, with identical dimensions, configurations and materials specified for commercial use. Scale models are not permissible.1.3 As each stormwater treatment device is unique in design, so are its hydraulic characteristics (flow versus head and loss coefficients). A sufficient number of accurately measured data points are needed to properly define the hydraulic characteristics of each test unit. Therefore, it is imperative that the unit setup and subsequent testing methodologies be well defined and executed to ensure accurate flow and elevation data.1.4 The values stated in inch-pound units are to be regarded as standard, except for methods to establish and report sediment concentration and particle size. It is convention to exclusively describe sediment concentration in mg/L and particle size in mm or µm, both of which are SI units. The SI units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard. Reporting of test results in units other than inch-pound units shall not be regarded as non-conformance with this test method.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This test method provides test results for evaluating the potential for scour of sediment captured within a MTD in online and offline configurations.5.2 This test method will determine if an MTD can meet the scour performance requirements prescribed by an associated verification protocol or local AHJ requirements.1.1 This test method covers the testing of hydrodynamic stormwater separators and underground settling devices as it relates to the measurement of the resuspension and washout (scour) of previously captured sediment.1.2 Units tested shall be of a size commonly manufactured and available for purchase. In order to facilitate testing it is permissible to substitute alternate materials for the housing and structural components of the test units if operational components are at full size, with identical dimensions, configurations and materials specified for commercial use. Scale models are not permissible.1.3 The test method provides a means of evaluating retention of suspended solids previously captured with a manufactured treatment device (MTD) that is placed as an offline or online treatment device along storm drain pipe lines. It provides criteria in which to evaluate whether the MTD is appropriate for installation in offline or online conditions.1.4 This test method provides the means for evaluating the scour potential for both offline and online conditions.1.5 Units—The values stated in inch-pound units are to be regarded as standard, except for methods to establish and report sediment concentration and particle size. It is convention to exclusively describe sediment concentration in mg/L and particle size in mm or μm, both of which are SI units. The SI units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard. Reporting of test results in units other than inch-pound units shall not be regarded as non-conformance with this test method.1.6 This test method may be subject to specific requirements set by a Quality Assurance Project Plan, a specific verification protocol, or Authority Having Jurisdiction (AHJ). It is advised to review one or all of the above to ensure compliance1.7 Acceptance of test results attained according to this specification may be subject to specific requirements set by a Quality Assurance Project Plan, a specific verification protocol, or Authority Having Jurisdiction (AHJ). It is advised to review one or all of the above to ensure compliance.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This practice provides criteria for the verification of the silica sediment removal efficiency of hydrodynamic separators.4.2 Verification can be used to support certification of the technology within different AHJs provided that:4.2.1 HDS units are sized using the resulting performance data to treat the prescribed water quality flow rate or annual mass load requirement at the level of performance desired by the certifying entity.4.2.2 Scaling of results to different MTD model sizes is in accordance with this standard.4.2.3 The technology is designed consistently with the tested unit such that it operates within the specified limits determined by the verification as well as other restrictions placed by the certification entity.1.1 This practice covers the criteria for the laboratory verification of Hydrodynamic Separators (HDS) as it relates to the removal of suspended solids in stormwater runoff.1.2 HDS manufactured treatment devices are placed as offline or online treatment devices along storm drain pipe lines to remove suspended solids and associated pollutants from stormwater runoff. These devices may be used to target removal of other pollutants which are not covered in this standard. The criteria in this standard specifically relate to the removal of silica particles in controlled laboratory conditions, which is considered an appropriate surrogate for predicting the removal of stormwater solids from actual stormwater runoff.1.3 This practice provides guidelines for independent regulatory entities, collectively referred to as Authority Having Jurisdictions (AHJs), to streamline data requirements for the certification of HDS devices within their jurisdiction. For any given AHJ, additional criteria may also apply.1.4 Units—The values stated in inch-pound units are to be regarded as standard, except for methods to establish and report sediment concentration and particle size. It is convention to exclusively describe sediment concentration in mg/L and particle size in mm or μm, both of which are SI units. The SI units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard. Reporting of test results in units other than inch-pound units shall not be regarded as non-conformance with this test method.1.5 Acceptance of test results attained according to this specification may be subject to specific requirements set by a Quality Assurance Project Plan (QAPP), a specific verification protocol, or AHJ. It is advised to review one or all of the above to ensure compliance.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.NOTE 1: This practice is also intended to ensure that the data resulting from completion of testing in accordance with the ASTM test methods referenced herein can be utilized to satisfy the requirements of the New Jersey Department of Environmental Protection’s manufactured treatment device (MTD) certification process.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
4 条记录,每页 15 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页