微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 78元 / 折扣价: 67 加购物车

在线阅读 收 藏

This specification covers blended uranium oxides with a 235U content of less than 5% for direct hydrogen reduction to nuclear grade uranium dioxide. For commercial-grade uranium oxide with an isotopic content of 235U between that of natural uranium and 5%, the isotopic limits shall apply. Physical and chemical requirements include: uranium content, oxygen-to-uranium ratio, impurity content, equivalent boron content, bulk density, moisture content, ability to flow, particle size, and reduction and sinterability. Maximum concentration limit is specified for impurity elements such as: aluminum, barium, beryllium, bismuth, calcium+magnesium, carbon, chlorine, chromium, cobalt, copper, fluorine, iron, lead, manganese, molybdenum, nickel, phosphorus, silicon, sodium, tantalum, thorium, tin, titanium, tungsten, vanadium, and zinc. The identity of a lot shall be retained throughout.1.1 This specification covers blended uranium trioxide (UO3), U3O8, or mixtures of the two, powders that are intended for conversion into a sinterable uranium dioxide (UO2) powder by means of a direct reduction process. The UO2 powder product of the reduction process must meet the requirements of Specification C 753 and be suitable for subsequent UO2 pellet fabrication by pressing and sintering methods. This specification applies to uranium oxides with a 235U enrichment less than 5 %.1.2 This specification includes chemical, physical, and test method requirements for uranium oxide powders as they relate to the suitability of the powder for storage, transportation, and direct reduction to UO2 powder. This specification is applicable to uranium oxide powders for such use from any source.1.3 The scope of this specification does not comprehensively cover all provisions for preventing criticality accidents, for health and safety, or for shipping. Observance of this specification does not relieve the user of the obligation to conform to all international, national, state, and local regulations for processing, shipping, or any other way of using uranium oxide powders (see 2.2 and 2.3).1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.5 The following safety hazards caveat pertains only to the test methods portion of the annexes in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

It includes GI #2. 1. Scope 1.1 This Standard applies to enclosed equipment that is to be permanently field connected to line or load circuits rated 750 V or less. 1.2 Minimum wiring space and wire bending space requirements are specified for f

定价: 455元 / 折扣价: 387

在线阅读 收 藏

5.1 For PM materials containing less than two percent porosity, a density measurement may be used to determine if the part has been densified, either overall or in a critical region, to the degree required for the intended application. Density alone cannot be used for evaluating the degree of densification because chemical composition and heat treatment affect the pore-free density.5.2 For cemented carbides, a density measurement is normally used to determine if there is any significant deviation in composition of the carbide grade. For straight tungsten carbide-cobalt grades, the relationship is straightforward. For complex carbide grades (for example, grades containing tantalum carbide or titanium carbide, or both, in addition to tungsten carbide-cobalt), the situation is more complicated. If the measured density is beyond the specified limits, the composition is outside of the specified limits. A measured density within the specified limits does not ensure correct composition; compensation between two or more constituents could result in the expected density with the wrong composition. Density alone cannot be used for evaluating a cemented carbide grade.1.1 This test method covers the determination of density for powder metallurgy (PM) materials containing less than two percent porosity and for cemented carbides. This test method is based on the water displacement method.NOTE 1: A test specimen that gains mass when immersed in water indicates the specimen contains surface-connected porosity. Unsealed surface porosity will absorb water and result in calculated density values higher than the true value. This test method is not applicable if this problem occurs, and Test Methods B962 should be used instead.1.2 Units—With the exception of the values for density and the mass used to determine density, for which the use of the gram per cubic centimetre (g/cm3) and gram (g) units is the long-standing industry practice, the values in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification describes a high fire-point mineral oil based electrical insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatuses, such as transformers and switchgear. The material discussed here is miscible with other petroleum based insulating oils, and may not be miscible with electrical insulating liquids of non-petroleum origin. The insulating oils shall be compatible with typical material of construction of existing apparatus and will satisfactorily maintain its functional characteristic in its application. This specification applies only to new insulating material oil as received prior to any processing. Sampled specimens shall undergo appropriate tests, and shall conform correspondingly to specified physical (appearance upon visual examination, color in ASTM units, fire point, flash point, aniline point, interfacial tension, pour point, relative density, and kinematic viscosity), electrical (dielectric breakdown voltage, gassing tendency, and dissipation factor), and chemical (corrosion behavior against sulfur, inorganic chlorides and sulfates content, acid number, water content, oxidation stability, oxidation inhibitor content, and PCB content) property requirements.1.1 This specification describes a less flammable mineral electrical insulating liquid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus, such as transformers and switchgear.1.2 Less flammable insulating liquid differs from conventional mineral insulating liquid by possessing a fire-point of at least 300 °C. This property is necessary in order to comply with certain application requirements of the National Electrical Code (Article 450-23) or other agencies. The material discussed in this specification is miscible with other petroleum based insulating liquids. Mixing less flammable liquids with lower fire point hydrocarbon insulating liquids (for example, Specification D3487 mineral liquid) may result in fire points of less than 300 °C.1.3 This specification is intended to define a less flammable electrical mineral insulating liquid that is compatible with typical material of construction of existing apparatus and will satisfactorily maintain its functional characteristic in this application. The material described in this specification may not be miscible with electrical insulating liquids of non-petroleum origin. The user should contact the manufacturer of the less flammable insulating liquid for guidance in this respect.1.4 This specification applies only to new electrical insulating liquid as received prior to any processing. Information on in-service maintenance testing is available in appropriate guides.2 The user should contact the manufacturers of the equipment or liquid if questions of recommended characteristics or maintenance procedures arise.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification deals with polymer precoated, closed rib steel pipes intended for use for storm water drainage, underdrains, the construction of culverts, and similar uses. The pipes covered here are not normally used for conveyance of sanitary or industrial wastes, and are of Type ICR, which have a full circular cross section and single thickness of smooth sheet, fabricated with outwardly projecting closed helical ribs. The steel sheet used for fabricating the pipe has a polymer protective coating over a zinc metallic coating. This specification does not include requirements for bedding, backfill, or the relationship between earth cover load and sheet thickness of the pipe. Pipes shall conform to dimensional and physical requirements such as nominal inside diameter, closed rib profile size, rib width, depth and spacing, sheet thickness, and lock seam tensile strength per unit width. Damaged coatings shall be repaired by paints containing zinc dust, metallizing coatings, or polymer coatings of similar characteristics.1.1 This specification covers polymer precoated, closed rib steel pipe, intended for use for storm water drainage, under-drains, the construction of culverts, and similar uses. Pipe covered by this specification is not normally used for the conveyance of sanitary or industrial wastes. The steel sheet used in fabrication of the pipe has a polymer protective coating over a metallic coating of zinc.1.2 The polymer precoating provides extra protection of the base metal against corrosion or abrasion, or both, in addition to that provided by the metallic coating. Severe environments are likely to cause corrosion problems to accessory items such as coupling band hardware that does not have a polymer coating unless supplemental protection is provided. Additional protection for polymer precoated steel pipe is available by use of coatings applied after fabrication of the pipe as described in Specification A 849.1.3 This specification does not include requirements for bedding, backfill, or the relationship between earth cover load and sheet thickness of the pipe. Experience with drainage products has shown that successful performance depends upon the proper selection of rib depth, sheet thickness, type of bedding and backfill, controlled manufacture in the plant, and care in installation. The installation procedure is described in Practice A 798/A 798M.1.4 This specification is applicable to orders in either inch-pound units as A 1019, or in SI units as A 1019M. Inch-pound units and SI units are not necessarily equivalent. SI units are shown in brackets in the text for clarity, but they are the applicable values when the material is ordered to A 1019M.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

1.1 This specification addresses less lethal chemical irritant sprays used by law enforcement, corrections, and other public safety officers.1.2 This specification is limited to duty belt-mounted canisters.1.3 This specification is limited to sprays intended for use on humans.1.4 This specification defines requirements for products containing liquid aerosol Oleoresin Capsicum (OC) spray (that is, pepper spray), Orthochlorobenzalmalononitrile (CS) spray (that is, 2–chlorobenzylidenemalononitrile; CAS #: 2698-41-1), or OC-CS combination spray. The formulation may be delivered as a stream, gel, foam, cone, or vapor.1.5 This specification does not address incendiary devices or “hot gas.”1.6 Products covered by this specification may be flammable or nonflammable.1.7 Products covered by this specification are hazardous substances as defined by 16 CFR 1500.3.1.8 It is intended that the following related practice be used in conjunction with this specification: Practice E3215.1.9 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.9.1 For some quantities in Sections 9, 10, and 11, only SI units are used to be consistent with industry practice.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
AS 1725-1975 Galvanized rail-less chainwire security fences and gates 现行 发布日期 :  1970-01-01 实施日期 : 

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

5.1 The measurement of total moisture is required to determine whether coal meets commercial or environmental specifications, or both. Within the limitations prescribed in the scope, this practice describes a procedure for determination of total moisture that requires less time than the procedures described in Test Method D3302/D3302M.1.1 This practice covers a single-stage procedure for the determination of total moisture less than 15 % in coal reduced to 2.36 mm [No. 8 sieve] topsize. This practice is for determination of total moisture only. Materials subjected to this test shall not be used in the determination of other test parameters. It is recognized that the conditions of the test can increase the potential for significant oxidation effects on some coals. If the oxidation potential is of concern, the use of this single-stage method shall involve prior agreement between the parties involved. This practice shall not be construed as the referee standard practice for total moisture. For referee purposes, users of this practice are referred to Test Method D3302/D3302M for moisture determination methods which are not as susceptible to oxidation effects.1.2 Statistical analysis of data from several sources indicates that at a 95 % confidence level, there is statistically no difference between the mean value of the results obtained by Practice D2961/D2961M and Test Method D3302/D3302M (that is, no bias is detected between the two methods at the 95 % confidence level) for moisture levels between 1.4 % and 15.8 %. These two standards were not compared in this study for some ranks of coal including lignite and anthracite.21.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This practice establishes the certification requirements for less lethal aerosol devices used by law enforcement, corrections officers, and other public safety officers.1.1.1 This practice is intended to be used by certification bodies and by purchasers and suppliers in the procurement of less lethal aerosol devices that meet Specification E3187/E3187M.1.1.2 The performance, testing, labeling, documentation, and reporting requirements for certification are specified in Specification E3187/E3187M.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 7462元 / 折扣价: 6343

在线阅读 收 藏

Scope: Details test and examination criteria for automatic storage water
heaters with input ratings of 75,000 Btu per hour (21 980 W) or less for use with natural, manufactured and mixed gases, liquefied petroleum gases, and LP gas-air mixtures.

定价: 819元 / 折扣价: 697

在线阅读 收 藏

1.1 This specification covers less-flammable (high fire point) synthetic ester insulating liquids for use as a dielectric and cooling in new and existing electrical power apparatus including power and distribution transformers, switchgear, and other associated equipment1.2 Synthetic ester insulating liquids differ from conventional mineral oil and other less-flammable (high fire point) liquids in that they are products derived from the chemical reaction, processing, and physical treatments of a carboxylic acid and an alcohol.1.3 This specification is intended to define synthetic ester electrical insulating liquids that are compatible with typical materials of construction of existing apparatus and are expected to maintain their functional characteristics in these applications. The material described in this specification is not always miscible with other electrical insulating liquids. The user should contact the manufacturer of the synthetic ester insulating liquid for guidance in this respect.1.4 This specification applies only to unused synthetic ester insulating liquids as received prior to any processing. The user should contact the manufacturer of the equipment or liquid, or both, if questions of recommended characteristics or liquid maintenance procedures arise.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
27 条记录,每页 15 条,当前第 1 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页