微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 345元 / 折扣价: 294

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 345元 / 折扣价: 294

在线阅读 收 藏

定价: 124元 / 折扣价: 106 加购物车

在线阅读 收 藏

定价: 345元 / 折扣价: 294 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

定价: 481元 / 折扣价: 409

在线阅读 收 藏

5.1 This test method for the chemical analysis of nickel and nickel alloys is primarily intended to test material for compliance with specifications such as those under jurisdiction of ASTM committee B02. It may also be used to test compliance with other specifications that are compatible with the test method.5.2 It is assumed that all who use this method will be trained analysts capable of performing common laboratory procedures skillfully and safely, and that the work will be performed in a properly equipped laboratory.5.3 This is a performance-based method that relies more on the demonstrated quality of the test result than on strict adherence to specific procedural steps. It is expected that laboratories using this method will prepare their own work instructions. These work instructions will include detailed operating instructions for the specific laboratory, the specific reference materials employed, and performance acceptance criteria. It is also expected that, when applicable, each laboratory will participate in proficiency test programs, such as described in Practice E2027, and that the results from the participating laboratory will be satisfactory.1.1 This test method describes the inductively coupled plasma mass spectrometric analysis of nickel and nickel allys, as specified by Committee B02, and having chemical compositions within the following limits:Element Application Range (Mass Fraction %)Aluminum 0. 01–6.00Boron 0. 01–0.10Carbon 0. 01–0.15Chromium 0. 01–33.00Copper 0.01–35.00Cobalt 0. 01–20.00Iron 0.05–50.00Magnesium 0. 01–0.020Molybdenum 0. 01–30.0Niobium 0. 01–6.0Nickel 25.00–100.0Phosphorous 0.001–0.025Silicon 0.01–1.50Sulfur 0.0001–0.01Titanium 0.0001–6.0Tungsten 0.01–5.0Vanadium 0.0005–1.01.2 The following elements may be determined using this method.Element Quantification Range (μg/g)Antimony 0.5–50Bismuth 0.1–11Gallium 2.9–54Lead 0.4–21Silver 1–35Tin 2.2–97Thallium 0.5–3.01.3 This method has only been interlaboratory tested for the elements and ranges specified. It may be possible to extend this method to other elements or different composition ranges provided that method validation that includes evaluation of method sensitivity, precision, and bias as described in this document is performed. Additionally, the validation study must evaluate the acceptability of sample preparation methodology using reference materials and/or spike recoveries. The user is cautioned to carefully evaluate the validation data as to the intended purpose of the analytical results. Guide E2857 provides additional guidance on method validation.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety hazard statements are given in Section 9.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

3.1 For custody transfer and other purposes, it is frequently necessary to convert a component analysis of light hydrocarbon mixture from one basis (either gas volume, liquid volume, or mass) to another.3.2 The component distribution data of light hydrocarbon mixtures can be used to calculate physical properties such as relative density, vapor-pressure, and calorific value. Consistent and accurate conversion data are extremely important when calculating vapor, liquid, or mass equivalence.1.1 This practice describes the procedure for the interconversion of the analysis of C5 and lighter hydrocarbon mixtures to gas-volume (mole), liquid-volume, or mass basis.1.2 The computation procedures described assume that gas-volume percentages have already been corrected for nonideality of the components as a part of the analytical process by which they have been obtained. These are numerically the same as mole percentages.1.3 The procedure assumes the absence of nonadditivity corrections for mixtures of the pure liquid compounds. This is approximately true only for mixtures of hydrocarbons of the same number of carbon atoms, and in the absence of diolefins and acetylenic compounds.1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
197 条记录,每页 15 条,当前第 1 / 14 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页