1.1 This guide sets a protocol for generating and reporting measurements that are traceable to SI units or Certified Reference Materials in laboratories that serve the metals industries.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the application of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 This guide establishes basic requirements which should be met by water and environmental laboratories that generate and report test chemical analyses which the laboratory client desires to be traceable to SI units (Note 1) or certified reference materials traceable to SI units. Traceability of chemical analyses is important because it provides a uniform basis for the comparison of results from different measurement systems and because it relates those results to our current knowledge of physical laws (Note 2).NOTE 1: A certified reference material traceable to SI units is a certified reference material whose value can be related with a stated uncertainty through an unbroken change of comparisons to stated references (usually national or international standards) in SI units, such as a primary measurement made in SI units or a national standard certified in SI units.NOTE 2: Not all chemical analysis results can be traceable to SI units or to certified reference material’s traceable to SI units, such as turbidity and or total suspended solids.4.2 Many waters-related laboratories comply with ISO Guide 17025 and participate in Proficiency Testing Programs. Laboratories that are connected to the same accreditation bodies and Proficiency Test providers can be expected to report statistically similar results on the same sample. However, some test methods and some certified reference materials are not supported with data traceable to SI units. Therefore, fully compliant laboratories that are not connected to the same providers may report statistically different chemical analysis results if they used the same nontraceable test method on the same sample. This problem could be minimized if they used test methods, measurement devices, and certified reference materials that are traceable to SI units, where available.4.3 Although some standard test methods and certified reference materials provide evidence of traceability to SI units, many others do not. Therefore, not all laboratories can be expected to universally meet all requests for traceable analyses until the traceability of more test methods and certified reference materials is recognized through appropriate documentation.4.4 The primary significance of this guide is that it establishes a consensus that, in order for a laboratory to generate traceable measurements, it must (1) have a clear understanding of the needs of the user of the traceable measurements, (2) comply with the internationally accepted quality-system requirements included in ISO Guide 17025, (3) use test methods, measurement devices, and certified reference materials which have been shown to be traceable to SI units, and (4) be able to demonstrate that the measurement system was in statistical control at the time the measurements were made.4.5 It is expected that this guide will be used by Committee D19 in setting policies for the technical content of its standards that are designated to be usable to generate traceable chemical analyses.1.1 This guide sets a protocol for generating and reporting chemical analyses that are traceable to SI units or to certified reference materials in laboratories that serve the water and environmental industry.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

6.1 Methods A or B are useful in testing hermetically-sealed devices with internal volumes. Maximum acceptable leak rates have been established for microelectronic devices to assure performance characteristics will not be affected by in-leakage of air, water vapor or other contaminants over the projected life expected. Care must be taken to control the bombing pressure, bombing time and dwell time after bombing or the results can vary substantially.1.1 This practice2 covers procedures for testing devices that are sealed prior to testing, such as semiconductors, hermetically enclosed relays, pyrotechnic devices, etc., for leakage through the walls of the enclosure. They may be used with various degrees of sensitivity (depending on the internal volume, the strength of the enclosure, the time available for preparation of test, and on the sorption characteristics of the enclosure material for helium). In general practice the sensitivity limits are from 10−10 to 10−6 Pa m3/s (10−9 standard cm3/s to 10−5 standard cm3/s at 0°C) for helium, although these limits may be exceeded by several decades in either direction in some circumstances.1.2 Two test methods are described:1.2.1 Test Method A—Test part preparation by bombing.1.2.2 Test Method B—Test part preparation by prefilling.1.3 Units—The values stated in either SI or std-cc/sec units are to be regarded separately as standard. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This test method covers the test procedure for determining the axial pull-out strength of medical bone screws. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 Glass fiber contents, determined by this test method, are useful for quality control of GFRC products to ensure that manufacturing equipment has been set up to deliver the correct proportions of glass fiber reinforcement in a GFRC composite.1.1 This test method covers determination of the fiber content in an uncured, glass fiber reinforced concrete (GFRC) sample panel.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This test method covers testing of the hard tissue pull-out fixation strength of metallic staples used in the internal fixation of the musculoskeletal system. This test method may be used with physiologic bone or a synthetic substitute. It may also be used when testing in an aqueous or physiological solution. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 Preformed tape sealants are tacky, deformable solids that are used under compression between two substrates in a variety of sealing applications. In general, oil migration or plasticizer bleed-out is not desirable. However, in some limited instances, a controlled amount of plasticizer migration is sometimes desired in order to improve the penetration of the tape into the interstices of porous substrates. This test method is designed to indicate whether or not a preformed tape sealant exhibits oil or plasticizer migration and, if so, to what extent.1.1 This test method covers a laboratory procedure that can be used to determine the oil migration or plasticizer bleed-out of preformed tape sealants.1.2 The values stated in acceptable metric units are to be regarded as the standard. The values given in parentheses are for information only.1.3 The subcommittee with jurisdiction is not aware of any similar ISO standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 This test method is designed to compare all types of preformed gaskets under controlled conditions with respect to blow-out resistance. This test method may be used as a routine test when agreed upon between the purchaser and the seller.1.1 This test method covers the determination of the resistance against blow-out of preformed gaskets. The test is conducted under ambient conditions and should be used for comparison purposes only to select suitable designs and constructions for specific applications.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 The oil absorption value obtained by this test method gives information about the vehicle demand of the pigment when it is used in a pigment paste. Oil absorption values can be used to characterize pigments or batches of a given pigment.4.2 This test method differs from Test Method D1483 in that D1483 involves only a gentle stirring and folding of the pigment, whereas this test method requires a thorough rubbing action. Because the end points are different, the values obtained from the two test methods generally differ.1.1 This test method covers the determination of the oil absorption of pigments by the spatula rub-out technique.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏