微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 190元 / 折扣价: 162

在线阅读 收 藏

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

5.1 The test method is designed to demonstrate that all accessible surfaces and internal recesses or lumina of previously cleaned, reusable medical devices can be rendered free of recoverable microorganisms when processed in a specified sterilizer cycle.5.2 Surviving spores are recovered by swabbing, brushing, or irrigating with an elution fluid. Recovery methods may be enhanced by mechanical action, sonication, and repeated flushing with elution fluid.NOTE 1: The spore inoculation technique described in this test method is only one of the available procedures for testing the sterilization of devices. Spores on paper strips (biological indocators) are a traditional tool used to develop and monitor sterilization cycles and are also appropriate for the evaluation of sterilization of medical devices.51.1 This test method covers a reproducible procedure for testing processes used to sterilize reusable medical devices (instruments). This test method is not designed to validate a sterilization process, but tests an established sterilization cycle or process. It is a practical test of the effectiveness of a sterilization process applied to reusable medical devices. Bacterial spores more resistant to the test sterilant than the natural bioburden of the instrument are used as the test organisms. Commercially available liquid suspensions of bacterial spores are used to inoculate the instruments.1.2 This test method is intended for reusable medical devices cleaned in accordance with the device manufacturer's instructions and prepared for sterilization in accordance with the instructions for the sterilization process being used.1.3 This test method assumes that cleaned, reusable medical devices will be free of visible soil but may have remaining adherent bioburden. A worst-case bioburden can be represented by suspensions of bacterial endospores, which are commercially available for monitoring chemical or physical sterilization processes. These endospores should have a verifiable resistance (D value) to the specific process and sterilant being evaluated.21.4 It is impractical to test for the sterility of some devices by immersion in growth medium because of their complexity, size, and availability (for long-term incubation) or adverse effects on the devices from long-term immersion. Therefore, elution, rinsing, or swabbing techniques are used to recover test organisms from inoculated devices.1.5 A recovery control will be included by inoculation of a test device and use of the elution methods without applying the sterilization process being tested. A minimal recovery of 106 colony-forming unit (CFU)/mL per device is required for the recovery control.1.6 Results of the recovery control and process test cycle are compared to determine the effectiveness of the sterilization process.1.7 Results of the recovery control and applied inoculum are compared to determine the recovery efficiency, if desired.1.8 The procedure should reveal that tested devices are free of recoverable microorganisms when five or more consecutive tests are conducted.1.9 A knowledge of microbiological techniques is required to conduct these procedures.1.10 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

1 Scope This International Standard specifies requirements for the use of moist heat in sterilization process development, validation of the sterilization process and control of routine sterilization. It covers all moist heat processes, including sa

定价: 774元 / 折扣价: 658

在线阅读 收 藏

1 Scope 1.1 This International Standard establishes requirements and guidance for validation and routine control of ethylene oxide sterilization processes for medical devices. Particular attention is drawn to the need for specific testing for safe

定价: 819元 / 折扣价: 697

在线阅读 收 藏

1 Scope This International Standard specifies requirements for validation, process control and routine monitoring in the r adiation sterilization of health care products. It applies to continuous and batch type gamma irradiators using the radionuclide

定价: 1274元 / 折扣价: 1083

在线阅读 收 藏

1 Scope This part of ISO 11140 specifies performance requirements for indicators that show exposure to sterilization processes by means of physical and/or chemical change of substances. NOTE 1 These indicators are used to monitor the presence or at

定价: 455元 / 折扣价: 387

在线阅读 收 藏
33 条记录,每页 15 条,当前第 1 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页