5.1 The purpose of this practice is to provide data that can be used for comparison and evaluation of the accuracy of different CAS systems.5.2 The use of CAS systems and robotic tracking systems is becoming increasingly common and requires a degree of trust by the user that the data provided by the system meets necessary accuracy requirements. In order to evaluate the potential use of these systems, and to make informed decisions about suitability of a system for a given procedure, objective performance data of such systems are necessary. While the end user will ultimately want to know the accuracy parameters of a system under clinical application, the first step must be to characterize the digitization accuracy of the tracking subsystem in a controlled environment under controlled conditions.5.3 In order to make comparisons within and between systems, a standardized way of measuring and reporting point accuracy is needed. Parameters such as coordinate system, units of measure, terminology, and operational conditions must be standardized.1.1 This standard will measure the effects on the accuracy of computer assisted surgery (CAS) systems of the environmental influences caused by equipment utilized for bone preparation during the intended clinical application for the system. The environmental vibration effect covered in this standard will include mechanical vibration from: cutting saw (sagittal or reciprocating), burrs, drills, and impact loading. The change in accuracy from detaching and re-attaching or disturbing a restrained connection that does not by design require repeating the registration process of a reference base will also be measured.1.2 It should be noted that one system may need to undergo multiple iterations (one for each clinical application) of this standard to document its accuracy during different clinical applications since each procedure may have different exposure to outside forces given the surgical procedure variability from one procedure to the next.1.3 All units of measure will be reported as millimeters for this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 Approximately 650,000 primary total knee arthroplasties (TKAs) and 50,000 revision TKAs are performed in the United States annually (7, 8). There are between 100,000 and 200,000 anterior cruciate ligament knee injuries per year in the United States (9).1.1 This guide is intended as a resource for individuals and organizations when designing clinical trials and/or clinical registries and addresses the selection of patient-reported outcomes, safety outcomes, imaging outcomes and other topics related to knee reconstructive surgery (KRS) including: (1) knee replacement systems, (2) anterior cruciate ligament reconstruction, (3) knee meniscus implants or tissue engineered medical products (TEMPs), (4) articular cartilage implants or TEMPS, (5) peri-articular knee osteotomies, (6) peri-articular knee fractures (including distal femur, patella, and proximal tibia fractures), or other knee surgeries.1.2 In this guide, methods to measure the efficacy, effectiveness, and safety of KRS devices through standardizing clinical outcome measures are provided for designing, reviewing, and accepting human clinical trial protocols.1.3 This guide is intended to provide consistency in study design, review, regulatory approval, and health insurance coverage approval for knee reconstructive surgery to the health care market.1.4 For the purpose of this guide, KRS pertains to any device or TEMP that is intended to replace, resurface, reconstruct, and/or provide fixation of the knee joint, in part or in total, as a treatment for joint disease, trauma, or dysfunction, where long-term improvement in function and pain relief without major adverse events are the desired outcomes.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 Approximately 500 000 primary total hip arthroplasties (THAs) and 66 000 revision THAs are predicted to be performed in the United States in 2020 (7). There are an estimated 340 000 hip fractures per year in the United States (8).1.1 This guide is intended as a resource for individuals and organizations when designing clinical trials and/or clinical registries and addresses the selection of patient-reported outcomes, safety outcomes, imaging outcomes, and other topics related to hip reconstructive surgery (HRS) including: (1) hip replacement systems, (2) hip fracture surgery, (3) acetabular fracture surgery, (4) hip arthroscopy and/or labrum repairs, and (5) peri-acetabular osteotomies, or other hip surgeries.1.2 In this guide, methods to measure the efficacy, effectiveness, and safety of HRS devices through standardizing clinical outcome measures are provided for designing, reviewing, and accepting human clinical trial protocols.1.3 This guide is intended to provide consistency in study design, review, regulatory approval, and health insurance coverage approval for hip reconstructive surgery to the health care market.1.4 For the purpose of this guide, HRS pertains to any device or tissue-engineered medical product (TEMP) that is intended to replace, resurface, reconstruct, and/or provide fixation of the hip joint, in part or in total, as a treatment for joint disease, trauma, or dysfunction, where long-term improvement in function and pain relief without major adverse events are the desired outcomes.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
AS 2265-1983 Surgical implants - Acrylic resin cements, for use in surgery 现行 发布日期 :  1970-01-01 实施日期 : 

定价: 481元 / 折扣价: 409 加购物车

在线阅读 收 藏

1 Scope This part of ISO 5841 specifies requirements for reports on the clinical performance in humans of population samples of pulse generators or leads, intended for long-term implantation as cardiac pacemakers, hereinafter referred to as devices. It

定价: 683元 / 折扣价: 581

在线阅读 收 藏

1 Scope This part of ISO 5841 specifies a connector assembly to be used to connect implantable pacemaker leads to implantable pacemaker pulse generators. Essential dimensions and performance requirements related to connector fit are specified, togethe

定价: 455元 / 折扣价: 387

在线阅读 收 藏