【国外标准】 Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
6.1 The objective of this practice is to standardize the evaluation method for assessing the hemolytic effect of a blood pump used in extracorporeal circulation and/or circulatory assistance. By comparing the hemolysis results between a subject device and a comparator device through paired testing, a relative evaluation of hemolysis for the subject device can be made.1.1 This practice covers a protocol for the assessment of the hemolytic properties of continuous, intermittent, and pulsatile flow blood pumps used in circulatory assist, including extracorporeal, percutaneous, and implantable devices. An assessment is made based on the pump's effects on the erythrocytes over a certain period of time. Adopting current practices for this assessment, a 6-hour in vitro test is performed on a pump placed in a device-specific recirculating blood loop that mimics the pressure and flow conditions of the expected worst-case clinical use of the device. If the ultimate goal of the testing is to evaluate the blood damage potential of a pump for clinical use, it is suggested that paired testing between the subject blood pump and a legally marketed comparator device be conducted using the same blood pool in a matched blood test loop so that a relative hemolysis comparison can be made.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F1841-19e1
标准名称:
Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps
英文名称:
Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E2102-21 Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
- ASTM E2103/E2103M-19 Standard Classification for Bridge Elements—UNIFORMAT II
- ASTM E2104-22 Standard Practice for Radiographic Examination of Advanced Aero and Turbine Materials and Components
- ASTM E2106-00(2019) Standard Practice for General Techniques of Liquid Chromatography-Infrared (LC/IR) and Size Exclusion Chromatography-Infrared (SEC/IR) Analyses
- ASTM E2107-20 Standard Practice for Environmental Regulatory Compliance Audits
- ASTM E2108-16 Standard Practice for Calibration of the Electron Binding-Energy Scale of an X-Ray Photoelectron Spectrometer
- ASTM E2109-01(2021) Standard Test Methods for Determining Area Percentage Porosity in Thermal Sprayed Coatings
- ASTM E211-82(2022) Standard Specification for Cover Glasses and Glass Slides for Use in Microscopy
- ASTM E2110-17 Standard Terminology for Exterior Insulation and Finish Systems (EIFS)
- ASTM E2112-23 Standard Practice for Installation of Exterior Windows, Doors and Skylights
- ASTM E2113-23 Standard Test Method for Length Change Calibration of Thermomechanical Analyzers
- ASTM E2114-23 Standard Terminology for Sustainability
- ASTM E2115-22 Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of Other Child-Occupied Facilities
- ASTM E2121-21 Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
- ASTM E2122-22 Standard Guide for Conducting In-situ Field Bioassays With Caged Bivalves