- 您的位置:
- 中国标准在线服务网 >>
- 全部标准分类 >>
- 国外标准 >>
- ASTM >>
- ASTM D1388-23 Standard Test Method for Stiffness of Fabrics
【国外标准】 Standard Test Method for Stiffness of Fabrics
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>
标准简介
适用范围:
5.1 In general, these procedures are more suitable for testing woven fabrics than knit fabrics.5.2 Both test options in this test method are considered satisfactory for acceptance testing of commercial shipments since current estimates of between-laboratory precision are acceptable and the method is used extensively in the trade for acceptance testing.5.2.1 In case of a dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens that are as homogeneous as possible and that are from a lot of material of the type in question. Test specimens should then be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using the appropriate statistical analysis and an acceptable probability level chosen by the two parties before testing is begun. If a bias is found, either its cause must be found and corrected or the purchaser and the supplier must agree to interpret future test results with consideration to the known bias.5.3 The stiffness of a fabric may change with storage.5.4 No evidence has been found showing that bending length is dependent on the width of the test specimen. The tendency for specimens to curl or twist will affect the result, because of the rigidity provided at the edge of the specimen. Consequently, the wider the strip, the less important is the edge effect. For fabrics having only a slight tendency to curl, a 2.5 cm wide strip has been found to be satisfactory. As the tendency to curl increases, this width may be increased (see Note 10).5.5 This method differs from Test Method F3260 which requires tracking of sample surface orientation, and is used to evaluate absorbable and partially absorbable medical textiles.1.1 This test method covers the measurement of stiffness properties of fabrics. Bending length is measured and flexural rigidity is calculated. Two procedures are provided.1.1.1 Option A—Cantilever Test, employing the principle of cantilever bending of the fabric under its own mass.1.1.2 Option B—Heart Loop Test, employing the principle of a loop formed in a fabric strip and hung vertically.1.2 This test method applies to most fabrics including woven fabrics, air bag fabrics, blankets, napped fabrics, knitted fabrics, layered fabrics, pile fabrics. The fabrics may be untreated, heavily sized, coated, resin-treated, or otherwise treated.1.2.1 This method may be used to determine the stiffness of nonwoven materials (for example, hydroentangled, dry laid, needlepunch, resin bonded, thermal, and wet laid) or refer to Test Method D5732. To determine the stiffness of medical textiles (for example, surgical mesh, films, and membranes), refer to Test Method F3260.NOTE 1: The formula to calculate flexural rigidity in D5732-95 (2001) is incorrect and should not be used. Utilize the formula presented in 11.5 of Test Method D1388.1.3 Units—The values stated in SI units are to be regarded as the standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D1388-23
标准名称:
Standard Test Method for Stiffness of Fabrics
英文名称:
Standard Test Method for Stiffness of Fabrics标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- BS EN IEC 61753-082-02:2024 Fibre optic interconnecting devices and passive components. Performance standard
- BS ISO 5501-2:2024 Tobacco heating systems. Definitions and standard conditions for aerosol generation and collection
- BS ISO 5501-3:2024 Tobacco heating systems. Definitions and standard conditions for aerosol generation and collection
- BS ISO 5501-1:2024 Tobacco heating systems. Definitions and standard conditions for aerosol generation and collection
- BS ISO 24138:2024 Information and documentation. International Standard Content Code (ISCC)
- 24/30492859 DC BS EN IEC 61753-1 Fibre optic interconnecting devices and passive components - Performance standard
- BS EN IEC 61753-071-02:2020+A1:2024 Fibre optic interconnecting devices and passive components. Performance standard
- 24/30491443 DC standard
- KS D ISO 9226 금속 및 합금의 부식-대기의 부식성-부식성 평가를 위한 표준 시험편의 부식 속도 결정
- KS B 0831 비파괴검사 — 초음파탐상검사 — 표준 시험편
- 24/30489392 DC BS EN IEC 62358 Ferrite cores. Standard inductance factor for gapped cores and its tolerance
- BS ISO 19848:2024 - TC Tracked Changes. Ships and marine technology. Standard data for shipboard machinery and equipment
- BS ISO 19848:2024 Ships and marine technology. Standard data for shipboard machinery and equipment
- BS IEC 61360-7:2024 Standard data element types with associated classification scheme
- 24/30487130 DC BS EN 50566:2017/A2:2024 Product standard to demonstrate the compliance of wireless communication