
【国外标准】 Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is used primarily to determine the time to burn-through and the time to ignition of materials, products, and assemblies.5.2 Representative joints and other characteristics of an assembly shall be included in a specimen when these details are part of normal design.5.3 This test method is applicable to end-use products not having an ideally planar external surface. The heat flux shall be adjusted to be that which is desired at the average distance of the surface from the radiant panel.5.4 In this procedure, the specimens are subjected to one or more specific sets of laboratory test conditions. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from this test to predict changes in the fire-test-response characteristics measured. Therefore, the results are valid only for the fire test exposure conditions described in this procedure.5.5 Representative materials and thicknesses shall be included in a specimen when these details are part of normal design.5.6 This method can also be used for research and development of various material types to be included in larger-scale fire test assemblies (for example, Test Methods E119).5.7 Test Limitations: 5.7.1 The test results have limited validity if: (a) the specimen melts sufficiently to overflow the drip tray, or (b) explosive spalling occurs.5.7.2 Report observations of specimens that sag, deform, or delaminate.1.1 This fire-test-response test method assesses the response of materials, products, and assemblies to controlled levels of heat flux with an external igniter.1.2 The fire-test-response characteristics determined by this test method include the ignitability and time to burn-through of materials, products, and assemblies under well ventilated conditions.1.3 Heat, smoke, and mass loss rate are not within the scope of this test method, but are addressed by Test Method E1623.1.3.1 This test method uses the same burner as that described in Test Method E1623. Two burner types are described (Burner A and Burner B).1.4 Specimens are exposed to a constant heat flux up to 50 kW/m2 in a vertical orientation. Hot wires are used to ignite the combustible vapors from the specimen.1.5 This test method has been developed for evaluations, design, or research and development of materials, products, or assemblies, or for code compliance. The specimen shall be tested in thicknesses and configurations representative of actual end product or system uses.1.6 Limitations of the test method are listed in 5.7.1.7 This test method is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.1.8 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.1.9 The values stated in SI units are to be regarded as standard.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific information about hazards is given in Section 7.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E3048-22a
标准名称:
Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
英文名称:
Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E866-23 Standard Specification for Corrosion-Inhibiting Adhesive Primer for Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels
- ASTM E867-23 Standard Terminology Relating to Vehicle-Pavement Systems
- ASTM E870-82(2019) Standard Test Methods for Analysis of Wood Fuels
- ASTM E871-82(2019) Standard Test Method for Moisture Analysis of Particulate Wood Fuels
- ASTM E872-82(2019) Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels
- ASTM E874-19 Standard Practice for Adhesive Bonding of Aluminum Facings to Nonmetallic Honeycomb Core for Shelter Panels
- ASTM E875-20 Standard Practice for Evaluation of Fungal Control Agents as Preservatives for Aqueous-Based Products Used in the Paper Industry
- ASTM E877-21 Standard Practice for Sampling and Sample Preparation of Iron Ores and Related Materials for Determination of Chemical Composition and Physical Properties
- ASTM E878-20 Standard Test Method for Determination of Titanium in Iron Ores and Related Materials by Diantipyrylmethane Ultraviolet Spectrophotometry
- ASTM E879-20 Standard Specification for Thermistor Sensors for General Purpose and Laboratory Temperature Measurements
- ASTM E88-11(2017) Standard Practice for Sampling Nonferrous Metals and Alloys in Cast Form for Determination of Chemical Composition
- ASTM E882-10(2016)e1 Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory
- ASTM E887-21 Standard Test Method for Silica in Refuse-Derived Fuel (RDF) and RDF Ash
- ASTM E889-82(2023) Standard Test Method for Composition or Purity of a Solid Waste Materials Stream
- ASTM E90-23 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements