微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This specification provides design and construction criteria for large diameter flanges for use in high temperature, low pressure service such as internal combustion engine exhaust and forced ventilation systems. The flanges shall be classified according to types as follows: Type I and Type II. Number of holes, hole diameter, and bolt circle are identical for both Type I and Type II flanges. Drilling of flanges shall be in accordance with the specified requirements.1.1 This specification provides design and construction criteria for large diameter flanges sizes 14 NPS to 144 NPS, for use in high temperature (1000 °F), low pressure service (25 psig), such as internal combustion engine exhaust and forced ventilation systems.1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers requirements and test methods for materials, dimensions, workmanship, ring stiffness, flattening, joint systems, and a form of marking for polyethylene (PE) pipe of profile wall construction and with bell and spigot, heat fusion, extrusion welded or electrofusion joints for use in gravity flow applications, such as for sewers and drains. The PE profile wall pipe products cover six standard ring stiffness constant (RSC) classifications, namely 40, 63, 100, and 160, 250 and 400. These are referred to as RSC 40, RSC 63, RSC 100, RSC 160, RSC 250 and RSC 400. Referee testing, ring stiffness constant testing, flattening test, and joint tightness test shall be performed to meet the requirements prescribed.1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, ring stiffness, flattening, joint systems, and a form of marking for large diameter, 10 to 132 in. (250 to 3355 mm), inside diameter based polyethylene (PE) pipe of profile wall construction and with bell and spigot, heat fusion, extrusion welded or elctrofusion joints for use in gravity flow applications, such as for sewers and drains.NOTE 1: Pipe produced to this specification should be installed in accordance with Practice D2321 and with the manufacturer's recommendations.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 The test has been widely used as an indicator of the relative quality or competence of various sources of aggregate having similar mineral compositions. The results do not automatically permit valid comparisons to be made between sources distinctly different in origin, composition, or structure. Assign specification limits with extreme care in consideration of available aggregate types and their performance history in specific end uses.1.1 This test method covers testing sizes of coarse aggregate larger than 19 mm (3/4 in.) for resistance to degradation using the Los Angeles testing machine (Note 1).NOTE 1: A procedure for testing coarse aggregate smaller than 37.5 mm (11/2 in.) is covered in Test Method C131/C131M.1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 910元 / 折扣价: 774

在线阅读 收 藏

5.1 The demand for SPF insulation in homes and commercial buildings has increased as emphasis on energy efficiency increases. In an effort to protect the health and safety of both trade workers and building occupants due to the application of SPF, it is essential that reentry/reoccupancy-times into the structure where SPF has been applied, be established.5.2 Concentrations of chemical emissions determined in large-scale ventilated enclosure studies conducted by this practice may be used to generate source emission terms for IAQ models.5.3 The emission factors determined using this practice may be used to evaluate comparability and scalability of emission factors determined in other environments.5.4 This practice was designed to determine emission factors for chemicals emitted by SPF insulation in a controlled room environment.5.5 New or existing formulations may be sprayed, and emissions may be evaluated by this practice. The user of this practice is responsible for ensuring analytical methods are appropriate for novel compounds present in new formulations (see Appendix X1 for target compounds and generic formulations).5.6 This practice may be useful for testing variations in emissions from non-ideal applications. Examples of non-ideal applications include those that are off-ratio, applied outside of recommended range of temperature and relative humidity, or applied outside of manufacturer recommendations for thickness.5.7 The determined emission factors are not directly applicable to all potential real-world applications of SPF. While this data can be used for VOCs to estimate indoor environmental concentrations beyond three days, the uncertainty in the predicted concentrations increases with increasing time. Estimating longer term chemical concentrations (beyond three days) for SVOCs is not recommended unless additional data (beyond this practice) is used, see (1).45.8 During the application of SPF, chemicals deposited on the non-applied surfaces (for example, floors and ceilings) are the result of both gaseous phase emissions from the SPF and overspray. It is difficult to separate these two processes with current analytical methods. At present, the difference in how these two processes impact the long-term emissions is not known. This practice combines these two processes to generate data for modeling inputs.1.1 This practice describes procedures for measuring the chemical emissions of volatile and semi-volatile organic compounds (VOCs and SVOCs) from spray polyurethane foam (SPF) insulation samples in a large-scale ventilated enclosure.1.2 This practice is used to identify emission rates and factors during SPF application and up to three days following application.1.3 This practice can be used to generate emissions data for research activities or modeled for the purpose to inform potential reentry and reoccupancy times. Potential reentry and re-occupancy times only apply to the applications that meet manufacturer guidelines and are specific to the tested formulation.1.4 This practice describes emission testing at ambient room and substrate temperature and relative humidity conditions recognizing chemical emissions may differ at different room and substrate temperatures and relative humidity.1.5 This practice does not address all SPF chemical emissions. This practice addresses specific chemical compounds of potential health and regulatory concern including methylene diphenyl diisocyanate (MDI), polymeric MDI (MDI oligomeric polyisocyanates mixture), flame retardants, aldehydes, and VOCs including blowing agents, and catalysts. Although specific chemicals are discussed in this practice, other chemical compounds of interest can be quantified (see target compound and generic formulation list in Appendix X1). Other chemical compounds used in SPF such as polyols, emulsifiers, and surfactants are not addressed by this practice. Particulate sizing and distribution are also outside the scope of this practice.1.6 Emission rates during application are determined from air phase concentration measurements that may include particle bound chemicals. SVOC deposition to floors and ceilings is also quantified for post application modeling inputs. SVOC emission rates should only be used for modeling purposes for the duration of data collection.1.7 Four quantification methods are described for isocyanates. The method chosen should consider safety issues such as flammability, the expected concentration, the presence of isocyanate aerosol during the phase of interest (during and post application), and if the tested SPF is high or low pressure.1.8 This practice references similar standard practices for design, construction, performance evaluation, and use of full-scale chambers for chemical emission testing.1.9 This practice references methods for the collection and analysis of air samples.1.10 This practice applies to two-component open cell and closed cell SPF insulation system formulations that are processed using high-pressure or low-pressure installation processing practices and equipment.1.11 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. The application of SPF in a ventilated enclosure has the potential to generate a hazardous condition putting the individual responsible for spraying inserts at risk. It is the responsibility of the user of this standard to establish appropriate health and safety procedures and require appropriate certified personal protective equipment (PPE) to minimize chemical exposure. Individuals entering the ventilated enclosure during and after SPF application, for any amount of time, are expected to wear appropriate PPE.1.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.14 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

3.1 This practice is useful for preparing coked specimens for subsequent testing where the shapes desired cannot be fitted into the coking box described in Test Methods C831.3.2 This practice can be very sensitive to heating rates in coking. Thus, strict adherence to the coking procedure is necessary.1.1 This practice covers the preparation of coking of carbon-bearing material for subsequent testing such as modulus of rupture, slag testing, thermal conductivity, and thermal expansion. Test Methods C831 is the specified method for testing residual carbon.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This test method does not establish requirements for airtightness but provides means of assessing compliance with specified air-leakage rates established elsewhere.5.2 This test method is used to determine the airtightness of building envelopes or portions thereof by measuring the air leakage rate at specified reference pressure differentials.5.3 This test method provides:5.3.1 Specific directions for determining acceptable weather conditions for conducting the test.5.3.2 Two different test boundary preparation conditions; building envelope (9.1.1.1), and operational envelope (9.1.1.2).5.3.3 Testing conducted in a range of pressures from 10 Pa (0.04 in. WC) to 100 Pa (0.40 in. WC).5.4 A measurement of the air-leakage rate of the constructed building envelope. Test methods that measure the air permeance of materials (Test Method E2178) and air leakage of assemblies (Test Method E2357) alone do not address the various complexities of the constructed building envelope, including but not limited to design, sequence, constructability, workmanship, and the transitions between assemblies.5.5 This test method applies to all multizone and large building types and portions or subsections of buildings. It can be used to test envelopes that consist of a single zone or subsections of a zone that can be tested as a single zone. Test envelopes that are entirely composed of subsections separated by interior partitions or floors, or both, may be tested as a single zone by maintaining baseline relationships between these subsections throughout testing. (See Appendix X1. See also Test Methods E779 and E1827.) Isolated subsections, each with its own specified air-leakage rate, shall be treated as separate test envelopes and tested separately. While testing isolated subsections, monitoring must be conducted for any extraneous/flanking air movement between the different zones.5.6 The building preparations prior to testing (fenestration positions and preparation of intentional openings such as HVAC penetrations and equipment) are critically important and can have a strong influence on the final test results. This test method includes guidance for testing of the building envelope both including and excluding HVAC-related openings.5.7 Compliance with a specified air leakage rate does not imply that all potentially problematic leaks have been sealed.5.8 While this test determines the air leakage rate of an envelope, it does not identify the location of leakage sites.NOTE 1: See, for example, Practices E1186 for locating leaks. The location of leaks, in addition to their cumulative leakage area, is also an important determinant of leakage under normal operating conditions.1.1 This standard test method provides a quantitative field-test procedure and calculation method for assessing an air leakage rate using a fan-induced pressure differential(s) across the building envelope, generated by blower doors or equivalent equipment.1.2 Building setup conditions in accordance with defining the test boundaries appropriate for testing the envelope’s air leakage are defined in this test method.1.3 Procedure to determine the air pressure boundaries of the test envelope to be tested are provided in this test method.1.4 This test method applies to all multizone and large building types and portions or subsections thereof.1.5 This test method defines three test procedures: multipoint regression, repeated single point, and repeated two-point air leakage rate testing.1.6 This test method allows for testing the test envelope in a pressurized condition, a depressurized condition, or in both conditions and averaging the results.1.7 This test method applies to an air leakage rate specification with a reference pressure greater than 10 Pa (0.04 in. WC) and not greater than 100 Pa (0.40 in. WC).1.8 This test method describes two methods of preparation for the building in order to conduct the test: the building envelope where HVAC-related openings are excluded, and on the operational envelope where the HVAC-related openings are included.1.9 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550