微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This practice covers the procedures for filling low-pressure pressurized products in laboratory research and experimental work and in commercial refrigeration and pressure filling. Propellants and chemicals should be properly stored and handled. Care should be taken when handling sealing machinery such as crimpers and seamers and aerosol containers. Safety equipment should be installed and all basic and additional safety precautions should be properly disseminated and observed.1.1 This practice covers the filling of low-pressure pressurized products, either in the laboratory or in production.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 2.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 TDG is a Schedule 2 compound under the Chemical Weapons Convention (CWC). Schedule 2 chemicals include those that are precursors to chemical weapons, chemical weapons agents, or have a number of other commercial uses. They are used as ingredients to produce insecticides, herbicides, lubricants, and some pharmaceutical products. Schedule 2 chemicals can be found in applications unrelated to chemical weapons. TDG is both a mustard gas precursor and a degradant as well as an ingredient in water-based inks, ballpoint pen inks, dyes, and some pesticides.55.2 This method has been investigated for use with soil.1.1 This procedure covers the determination of thiodiglycol (TDG) in soil using pressurized fluid extraction (PFE). A commercially available PFE system2 is used, followed by analysis using liquid chromatography (LC), and detected with tandem mass spectrometry (MS/MS). TDG is qualitatively and quantitatively determined by this method. This method adheres to single reaction monitoring (SRM) mass spectrometry.1.2 The method detection limit (MDL) and reporting range for TDG are listed in Table 1.1.2.1 The MDL is determined following the Code of Federal Regulations, 40 CFR Part 136, Appendix B.1.2.2 The reporting limit (RL) is calculated from the concentration of the Level 1 calibration standard as shown in Table 4. The RL for this method is 200 ppb. Reporting range concentrations are calculated from Table 4 concentrations assuming a 5 μL injection of the lowest level calibration standard, 5 g sample, and a 2 mL final extract volume.1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This practice describes the procedure for obtaining a sample of pressurized gas for gas analysis from a system or component. A sample pressure vessel shall be evacuated and sealed with a minimum vacuum pressure. The vessel shall then be attached to the designated pressurized sample port. The pressurized gas is allowed to enter the sample vessel until the pressure is equal to the pressure of the system or component. The pressure shall be secured and the sample vessel assigned for appropriate analysis. The apparatus shall consist of connecting lines, miscellaneous fittings, tie-downs, and a gas sample vessel.1.1 This practice describes procedures for obtaining a sample of pressurized gas for gas analysis from a system or component.1.2 The values stated in SI units are to be regarded as the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For hazard statement, see Section 6.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
18 条记录,每页 15 条,当前第 2 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页