This specification covers the requirements for smooth-wall perforated and nonperforated poly(vinyl chloride) (PVC) plastic pipe and couplings for use in subsurface drainage systems of highways, airports, and similar applications. Two classes (or pipe stiffness) are included and designated as PS 28 and PS 46. The pipe stiffness, impact resistance, pipe flattening, and solvent cement joint tightness shall be tested to meet the requirements prescribed.1.1 This specification covers the requirements for smooth-wall perforated and nonperforated poly(vinyl chloride) (PVC) plastic pipe and couplings for use in subsurface drainage systems of highways, airports, and similar applications in nominal sizes of 4, 6, and 8 in. and in pipe stiffnesses (PS) that are designated as Type PS 28 and Type PS 46 in accordance with its minimum pipe stiffness.1.2 Molded fittings for use with highway underdrain pipe are in accordance with Specification D3034. For convenience, some of these fittings are reproduced in Annex A1.1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.NOTE 1: Type PS 28 and Type PS 46 indicate “pipe stiffness” of 28 and 46, respectively, as outlined in 11.1.NOTE 2: Pipe and fittings should be installed in accordance with Practice D2321, or applicable state or local specifications.1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The following safety hazards caveat pertains only to the test methods portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers the design, material, and minimum performance requirements for resilient connectors used to provide a positive seal between the pipe and manholes or other structures subjected to internal and external hydrostatic pressures less than 10.8 psi [74 KPa]. Testing under this specification is limited to hydrostatic pressures and conducted in a laboratory as a proof of design certification. Resilient materials for connectors and filler rings shall be manufactured from natural or synthetic rubber, shall display no fracture at -40 ºF [-40 ºC], and shall meet a minimum tear resistance of 200 lbf/in [34 kN/m] when tested. Expansion rings, tension bands, and take-up devices used for mechanically compressing the resilient portion of the connector against the pipe, manhole or wastewater structure shall be made from a material or materials in combination that will ensure durability, strength, resistance to corrosion, and continued resistance to leakage. Bolts, nuts, and other threaded items used with joining systems shall be zinc coated by one of the following processes: hot-dip process, electroplating process, or mechanical process. The same processes shall be used for zinc coating of other hardware items used with coupling bands.This specification also covers requirements for basis of acceptance, test methods, and product marking.1.1 This specification covers the design, material, and minimum performance requirements of resilient connectors used for connections between reinforced concrete structures conforming to Specifications C478 and C913 to corrugated steel drainage pipe conforming to Specifications A760 or A762.1.1.1 These connectors are designed to provide a positive seal between the pipe and manholes or other structures subjected to internal and external hydrostatic pressures less than 10.8 psi [74 KPa].1.1.2 Testing under this standard is limited to hydrostatic pressures. Alternate air and vacuum pressure testing involve unique testing protocols and are not addressed under this standard.1.1.3 Testing under this standard is conducted in a laboratory as a proof of design certification. Actual field performance testing would be accomplished and accepted under individual project performance standards or pipeline acceptance criteria, which is outside the scope of this standard.NOTE 1: Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI units are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.4.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers smoothwall perforated and nonperforated polyethylene (PE) pipe for use in drainage and waste disposal absorption fields. It covers requirements and test methods for workmanship, flattening, dimensions, tolerances, stiffness, perforations, environmental stress cracking, bonding, and impact resistance. Materials for pipe shall be PE compounds which may consist of lubricants, stabilizers, nonpoly(ethylene) resin modifiers, and pigments. Marking, labeling, installation, and quality assurance shall conform to the requirements of this specification.1.1 This specification covers requirements and test methods for workmanship, flattening, dimensions, tolerances, stiffness, perforations, environmental stress cracking, bonding, and impact resistance for smoothwall perforated and nonperforated polyethylene (PE) pipe, including coextruded and closed profile pipe. Methods of marking are also included.1.2 This specification includes two stiffness classes, referred to as, “Standard” and “Heavy Duty.”1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.4 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this specification.1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers post-applied coatings, pavings, and linings for corrugated steel pipe and corrugated steel structural plate pipe, pipe-arches, and arches coated, paved, or lined with specified materials over either metallic coatings or metallic coatings with polymer coatings. Asphalt, polymerized asphalt, polymer, mastic, and emulsion coatings and asphalt and concrete pavements and linings are included. Two-step classification procedure is used to describe post-applied coatings, pavings, and linings. The first classification is based on the type of coating, paving, or lining material to be used. The second is a coating, paving, and lining type giving the physical location of the coating or lining on the pipe.1.1 This specification covers post-applied coatings, pavings, and linings for corrugated steel pipe and corrugated steel structural plate pipe, pipe-arches, and arches coated, paved, or lined with specified materials over either metallic coatings or metallic coatings with polymer coatings. This specification includes asphalt, polymerized asphalt, polymer, mastic, and emulsion coatings and asphalt and concrete pavements and linings applied to the pipe in the producing plant, as well as, asphalt and mastic coatings applied in the field. Field-applied concrete pavements and linings are covered by Specification A979/A979M. The pipe to which the coatings are applied is described in Specifications A760/A760M, A761/A761M, and A762/A762M.1.2 There is no cleaning operation currently included in pipe coating practice. However, experience has shown that a clean substrate provides good adherence for both cold- and hot-applied post coatings. The performance of post coating or lining, or both, will depend on the surface cleanliness over which it is applied.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in brackets are for information only.1.4 The following safety hazards caveat pertains only to the test methods portions, Sections 11 and 12, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This practice covers the procedures for subsurface installation of corrugated polyethylene pipe, in accordance with the flexible conduit principles, intended for agricultural drainage or water table control. It is not however recommended for sanitary and storm sewer applications. General requirements for installation include: maximum and minimum burial depth; trench width; design of blinding, bedding, or envelope materials that are to be placed as the pipe is installed to ensure uniform continuous support; and granular or synthetic filters that are used to restrict the movement of particles into the pipe so as to maintain its hydraulic capacity. The pipe shall be aligned as smooth as possible with a curve radius larger than five times the pipe diameter while the backfill material shall be placed preferably on an angle to prevent pipe displacement or deflection. Stony trenches shall be avoided and any over-excavation or rock excavation shall be treated with proper bedding material. Factors that affect the proper handling of the pipe such as temperature; stretch caused by tension and bending forces; synthetic envelopes and filters that are subject to abrasion and tearing; and protection from fire hazards, livestock, heavy wheel traffic, and rodents or other animals shall also be considered during installation.1.1 This practice is recommended for and limited to gravity flow subsurface drainage systems or water table control, but not recommended for sanitary or storm sewer applications. Procedures are outlined to minimize pipe deflection or structural damage during and after the installation process. These installation procedures are in accordance with “flexible conduit” principles.1.2 This practice applies to all agricultural subsurface drainage or water table control installations using Specification F667, F2648, or other plastic pipe.NOTE 1: Specific references to the appendix in the body of this practice are for informational purposes.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only, may not be equivalents and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 This guide provides information and guidelines for the selection and installation of drainage systems media that are in conjunction with waterproofing systems. This guide is intended to be used in conjunction with Guides C898/C898M, C981, C1471/C1471M, D5898/D5898M, and D6622/D6622M and to provide guidelines for the total waterproofing and drainage system.1.1 This guide makes recommendations for the selection and application of prefabricated drainage media used in conjunction with waterproofing systems on horizontal and vertical surfaces. Drainage media considered include rigid and semi-rigid insulation boards and rigid materials including plastics. This guide considers drainage media as it relates to the performance of the waterproofing system, so its primary focus is draining water away from the membrane. This guide does not cover in detail other aspects or functions of drainage system performance such as efficiency of soil dewatering. The scope of this guide does not cover other drainage media including gravel and filter fabric systems that can be constructed. The scope of this guide does not cover drainage materials or drainage system designs used for vegetative roof systems. Vegetative roof systems require specialized designs.1.2 The committee with jurisdiction over this standard is not aware of any other comparable standards published by other organizations.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.4 This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers requirements and test methods for fabricated poly(vinyl chloride) (PVC) plastic schedule 40 drainage and DWV fittings. These fabricated fittings are manufactured from pipe, or from a combination of pipe and injection molded parts. Resistance to bending test, leak test, and solvent weld bond area test shall be performed to meet the requirements prescribed. The spigot diameter, spigot length, wall thickness, socket diameter, and socket length shall be tested to meet the requirements prescribed.1.1 This specification covers requirements and test methods for fabricated poly(vinyl chloride) (PVC) plastic schedule 40 drainage and DWV fittings to be used with piping manufactured in accordance with Specifications D2665 or F891. These fabricated fittings are manufactured from pipe, or from a combination of pipe and injection molded parts.1.2 The requirements of this specification are to provide fabricated PVC fittings suitable for drainage and venting of sanitary waste systems, storm water systems, and certain other liquid wastes. Fittings shall have solvent cement joints, gasket joints or a combination thereof.1.3 The text of this specification references notes, footnotes, and appendixes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.1.5 The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

3.1 Asphalt coating is used to provide additional protection for corrugated steel products (product) in corrosive or abrasive environments, or both.1.1 This practice covers the post coating of corrugated steel pipe and corrugated structural steel plate with asphalt materials. This practice is intended for shop-applied coating only.1.2 The values stated in either inch-pound units or SI units shall be regarded separately as standard. The values stated in each system are not exact equivalents; therefore, use each system independently of the other, without combining values in any way. The SI units are shown in brackets in the text for clarity, but they are the applicable values when the application is to be performed using SI units.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This test method is performance oriented for determining if, and to what degree, different liquids create biological activity on geotextile filters thereby reducing their flow capability. The use of the method is primarily oriented toward landfill leachates but can be performed with any liquid coming from a particular site or synthesized from a predetermined mixture of biological microorganisms.5.2 The test can be used to compare the flow capability of different types of geotextiles, drainage geocomposite, or soil/geotextile combinations.5.3 This test will usually take considerable time, for example, up to 1000 h, for the biological activity to initiate, grow, and reach an equilibrium condition. The curves resulting from the test are intended to indicate the in-situ behavior of a geotextile or soil/geotextile filter.5.4 The test specimen can be incubated under unsaturated drained conditions between readings, or kept saturated at all times. The first case allows for air penetration into the flow column and thus aerobic conditions. The second case can result in the absence of air; thus it may simulate anaerobic conditions.5.5 The flow rate can be determined using either a constant head test procedure or on the basis of a falling head test procedure. In either case, the flow column containing the geotextile or soil/geotextile is the same; only the head control devices change.NOTE 1: It has been found that once biological clogging initiates, constant head tests often pass inadequate quantities of liquid to accurately measure. It thus becomes necessary to use falling head tests, which can be measured based on time of movement of a relatively small quantity of liquid between two designated points on a clear plastic standpipe.5.6 If the establishment of an unacceptably high degree of clogging is seen in the flow rate curves, the device allows for back flushing with water or with water containing a biocide.5.7 The resulting flow rate curves are intended for use in the design of full-scale geotextile, drainage geocomposite, or soil/geotextile filtration systems and possible remediation schemes in the case of landfill leachate collection and removal systems.1.1 This test method is used to determine the potential for, and relative degree of, biological growth which can accumulate on geotextile, drainage geocomposites, or geotextile/soil filters.1.2 This test method uses the measurement of flow rates over an extended period of time to determine the amount of clogging.1.3 This test method can be adapted for unsaturated as well as saturated conditions.1.4 This test method can use constant head or falling head measurement techniques.1.5 This test method can also be used to give an indication as to the possibility of back flushing, biocide treatment, or both, for remediation purposes if biological clogging does occur.1.6 The values in SI units are to be regarded as the standard. The values provided in inch-pound units are for information only.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers the quality and grading of expanded shale, clay and slate (ESCS) for use as a mineral component of growing media and drainage layer for extensive and intensive vegetative (green) roof systems. ESCS is a lightweight, highly porous and low-density ceramic material produced by expanding and vitrifying select shale, clay or slate in a rotary kiln. The requirements are intended to cover only materials having normal or average gradation characteristics. This specification also describes the materials and manufacture, as well as physical and chemical properties.1.1 This specification covers the quality and grading of the following materials for use as a mineral component of growing media and drainage layer for extensive and intensive vegetative (green) roof systems. The requirements are intended to cover only materials having normal or average gradation characteristics. Procedures covered in this specification are not intended for evaluating the performance nutrients associated with vegetative (green) roof growing media. Where other materials are to be used, appropriate limits suitable to their use must be specified.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 This standard offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers circular-knit geotextiles for use on the outside of perforated pipes and Class B geocomposites in subsurface drainage applications. Material covered by this specification comprises Type A and Type B fabric geotextiles, which have been used extensively as filtration geotextiles in combination with subsurface drainage pipes. The geotextile shall be manufactured from polymeric materials by a circular-knit process, which will ensure a consistent, continuous fabric without seams. Tests for water permittivity, apparent opening size, and puncture strength shall be performed and shall conform to the requirements specified. Per service requirement, additional tests for chemical resistance and durability may be performed as well.1.1 This specification covers circular-knit geotextiles for use on the outside of perforated pipes and Class B geocomposites per Specification D7001 in drainage applications.1.2 The tests used to characterize the geotextile are intended to ensure good workmanship and quality, and are not necessarily adequate for design purposes in view of the importance of environmental factors and specific performance objectives. Tests have been selected with essentially neutral aqueous systems in mind. Other tests may be necessary to establish chemical resistance and durability under the conditions of a particular application.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This guide is for use by individuals and entities involved with the design and specification of EIFS details for a specific building.4.2 This guide can be applied to both EIFS-clad barrier wall assembly and EIFS-clad wall with drainage.4.3 This guide can be applied to new and existing EIFS buildings, prefabricated versus on-site installed EIFS, and residential and commercial EIFS buildings.4.4 This guide is not meant to replace the types of information normally present in text format in a project’s specifications.4.5 This guide is not applicable to EIFS materials used in non EIFS applications, such as a topcoat for other base materials like traditional Portland cement plaster (stucco) and concrete.1.1 This guide describes the types of project-specific construction conditions that need to be communicated by means of drawings (“details”) for the purpose of constructing Exterior Insulation and Finish System (EIFS)-clad barrier and drainage wall assemblies. EIFS manufacturers provide basic details for the installation of their materials and interface with adjacent materials. These details are generic and, in many cases, do not apply to specific project conditions.1.2 This guide addresses only the EIFS itself and the interface between the EIFS and the materials immediately adjacent to the EIFS; it does not address all parts of the wall assembly.1.3 Not all possible construction detail conditions are addressed by this guide. Identify and provide details for all construction conditions that exist on a specific building.1.4 This guide is intended to supplement but not supersede information from the EIFS manufacturer about how their specific product should be detailed, nor to supersede technical product acceptance reports or the code requirements of regulatory authorities.1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This specification covers requirements for non-pressure polyolefin pipe and fittings for drainage, waste, and vent applications.NOTE 1: This specification does not include requirements for pipe and fittings intended to be used to vent combustion gases.1.2 Pipe is produced in Schedule 40 and 80 IPS sizes, in metric sizes, and in DR IPS sizes for two polyolefins; polyethylene (PE) and polypropylene (PP).1.3 The interchangeability of pipe and fittings made by different manufacturers is not addressed in this specification.1.4 Pipe and fittings are joined by the heat fusion method (Practice D2657 for PP butt and saddle fusion, Practice F2620 for PE butt, saddle and socket fusion and Practice F1290 for polyolefin electrofusion) or by using mechanical or gasketed joints recommended by the pipe and fitting manufacturers.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.6 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.1.7 The following safety hazards caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
43 条记录,每页 15 条,当前第 3 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页