微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). The heaters shall be subject to glazing water shock test, glazing impact test, rain test, solubility test, and drop test.1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer’s instructions and are to be used in evaluating the room heater.1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR Part 3280.1.5 The terms “product” or “room heater,” as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏
ASTM F2022-01(2019) Standard Test Method for Performance of Booster Heaters Active 发布日期 :  1970-01-01 实施日期 : 

5.1 The energy input rate test is used to confirm that the booster heater is operating properly prior to further testing.5.2 Booster heater flow capacity is an indicator of the booster heater's ability to supply hot water for sanitation. The booster heater's flow capacity can be used by the operator to determine the appropriate size booster heater for their operation. Booster heater energy rate is an indicator of the booster heater's energy consumption during continuous water flow. The energy rate can be used by food service operators to estimate the energy consumption of the booster heater. Booster heater energy efficiency is a precise indicator of a booster heater's energy performance during the continuous flow test. This information enables the food service operator to consider energy performance when selecting a booster heater.5.3 Booster heater flow capacity at 50 % of the maximum capacity is an indicator of the booster heater's ability to provide hot water for sanitation at this reduce flow rate condition. Booster heater energy efficiency at a flow rate of 50 % of maximum capacity is an indicator of a booster heater's energy performance at this flow rate. The booster heater outlet temperature during the capacity test at a flow rate of 50 % of maximum capacity is an indicator of the booster heater's temperature response at this reduced flow rate.5.4 Preheat energy and time can be useful to food service operators to manage power demands and to know how quickly the booster heater can be ready for operation.5.5 Idle energy rate and pilot energy rate can be used to estimate energy consumption during standby periods.1.1 This test method evaluates the energy efficiency, energy consumption and water heating performance of booster heaters. The food service operator can use this evaluation to select a booster heater and understand its energy consumption.1.2 This test method is applicable to electric, gas, and steam powered booster heaters.1.3 The booster heater can be evaluated with respect to the following (where applicable):1.3.1 Energy input rate (9.2).1.3.2 Pilot energy rate (9.3).1.3.3 Flow capacity rate, energy rate, and energy efficiency with 110°F (43.3°C) and 140°F (60.0°C) supply to the booster heater inlet (9.4).1.3.4 Thermostat calibration (9.5).1.3.5 Energy rate and energy efficiency at 50% of flow capacity rate with 110°F (43.3°C) and 140°F (60.0°C) supply to the booster heater inlet (9.6).1.3.6 Preheat energy and time (9.7). The preheat test is not applicable to booster heaters built without water storage and will not have auxiliary water storage connected to the booster heater to complete the water heating system.1.3.7 Idle (standby) energy rate (9.8).1.4 The values stated in inch-pound units are to be regarded as standard. The SI units in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 The energy input rate test is used to confirm that the patio heater is operating properly prior to further testing.5.2 Preheat energy and time can be useful to food service operators to manage energy demands and to know how quickly the patio heater can be ready for operation.5.3 The temperature distribution of a patio heater can be used by operators and designers to determine the most effective layout for a patio heating system.5.4 The effective heated area can be used by operators to choose a patio heater that meets their heating needs.1.1 This test method covers the heating performance and energy consumption of commercial radiant patio heaters. The food service operator can use this evaluation to select a commercial patio heater and understand its energy performance and effective heated area.1.2 This test method is applicable to commercial gas and electric radiant patio heaters.1.3 The patio heater can be evaluated with respect to the following:1.3.1 Energy input rate (10.2),1.3.2 Preheat energy consumption and time (10.3),1.3.3 Temperature distribution (10.4), and1.3.4 Effective heated area (10.4).1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM F1369-93a Standard Specification for Heaters, Convection, Steam and Hot Water (Withdrawn 2002) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 345元 / 折扣价: 294

在线阅读 收 藏
ASTM E2817-11(2018) Standard Test Method for Test Fueling Masonry Heaters Active 发布日期 :  1970-01-01 实施日期 : 

5.1 This test method is used for determining emission factors and emission rates for cordwood or other densified, binder free biomass fuel burning masonry heaters.5.1.1 The emission factor is useful for determining emission performance during product development.5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from masonry heaters, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from masonry heaters based on results from this method.5.2 The reporting units are grams of particulate per kilogram of dry fuel (emissions factor), grams of particulate per hour of heating cycle (heating cycle emissions rate, based on the builder or manufacturer’s specified firing interval), and grams of particulate per hour of test run (combustion period emissions rate, based on the tested combustion period).5.3 Warning—Use of masonry heater emissions rate reporting numbers (grams per hour) for comparative purposes with other solid fuel burning appliances will require careful study of each of the appliance’s comparative operating characteristics in the given application. Intermittently fired appliances such as masonry heaters and continuously fired appliances such as wood and pellet stoves are not accurately compared by their respective emissions rates.1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from solid fuel biomass (cordwood or other densified, binder free biomass fuels) fires in masonry heaters. It may also be used to test other similar appliances (see 3.2.20).1.2 This test method is applicable to the operation and fueling of masonry heaters during particulate emissions measurement test periods. The prescribed methods and procedures of these protocols are performed on masonry heaters installed and operated in accordance with the builder or manufacturer’s specifications.1.3 In conjunction with Test Method E2515, this test method provides a protocol for laboratory emissions testing of masonry heaters that is intended to simulate actual use in residential homes and other consumer applications. Since such actual use involves almost solely cordwood fueling, Annex A1, Cordwood Fuel, provides as close a simulation as is currently possible of consumer use, and is recommended for predicting actual consumer emissions performance. For regulatory and other potential uses in comparing relative emissions of various masonry heater products and designs, Annex A2, Cribwood Fueling, and Annex A3, Cribwood Fuel, Top-Down Burn, provide optional additional fueling protocols that substitute dimensional lumber cribs for the cordwood fuel. Data that establish the relationships between the emissions results generated by Annex A2 and Annex A3 and the emissions results generated by Annex A1 are not currently available.1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 843元 / 折扣价: 717 加购物车

在线阅读 收 藏

12.1 The use of these acceptance tests will insure that organizations buying portable heaters will be assured the heaters meet certain performance requirements.AbstractThis specification is used to standardize the portable water heaters used on personnel decontamination lines to insure the heaters provide sufficient heated water for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The performance requirements for portable water heaters are presented in details. The rotometer test method, and ASTM test method shall be performed to meet the requirements prescribed. The water heater unit's water flow shall be measured, and recorded. The water heater unit's cold water inlet and warm water output temperature shall be measured and recorded. The water heater unit's water supply and outlet pressures shall be measured and recorded.1.1 This specification is used to standardize the portable water heaters used on personnel decontamination lines to insure the heaters provide sufficient heated water for as long as they are needed during the emergency.NOTE 1: These heaters are not intended to be used for the decontamination for any other surface or material. Also, these heaters are intended to be portable and easy to use by first responders during a chemical, biological, radiological, nuclear, and explosive (CBRNE) event.1.2 This specification contains a specification section and a test methods section so users need to refer to the section applicable to their needs when using this standard specification.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.NOTE 2: The U.S. first responder personnel using the equipment manufactured under this standard are not likely to be familiar with SI units so English units need to be included as part of the system documentation and shown on control panels for any equipment sold to U.S. organizations.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

11.1 The use of these acceptance tests will insure that organizations buying portable heaters will be assured the heaters meet certain performance requirements.AbstractThis specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit’s ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit’s air flow and input and output temperatures shall be performed.1.1 This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency.NOTE 1: These heaters are not intended to be used for the decontamination for any other surface or material. Also, these heaters are intended to be portable and easy to use by first responders during a chemical, biological, radiological, nuclear, and explosive (CBRNE) event.1.2 This specification contains a specification section and a test methods section so users need to refer to the section applicable to their needs when using this standard specification.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.NOTE 2: The U.S. first responder personnel using the equipment manufactured under this standard are not likely to be familiar with SI units so English units need to be included as part of the system documentation and shown on control panels for any equipment sold to U.S. organizations.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
ASTM F1369-93a Standard Specification for Heaters, Convection, Steam and Hot Water (Withdrawn 2002) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

1.1 This specification covers steam and hot water convection heaters with cabinets for use in heating spaces on commercial and naval ships. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 The following precautionary caveat pertains only to the tests portion, Section 12, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 The results of this test method may be used to determine nitrogen oxides and carbon monoxide emission concentrations from natural gas combustion at stationary sources.5.2 This test method may also be used to monitor emissions during short-term emission tests or periodically in order to optimize process operation for nitrogen oxides and carbon monoxide control.1.1 This test method covers the determination of nitrogen oxides (NO and NO2), carbon monoxide (CO), and oxygen (O2) concentrations in controlled and uncontrolled emissions from natural gas-fired reciprocating engines, combustion turbines, boilers, and process heaters using portable analyzers with electrochemical sensors. Due to the inherent cross sensitivities of the electrochemical cells, this test method should not be applied to other pollutants or emission sources without a complete investigation of possible analytical interferences and a comparative evaluation with EPA test methods.1.1.1 The procedures and specifications of this test method were originally developed during laboratory and field tests funded by the Gas Research Institute (GRI).2 Comparative emission tests were conducted only on natural gas-fired combustion sources. Subsequently, the U.S. Environmental Protection Agency (EPA) sponsored Environmental Technology Verification (ETV) program conducted further evaluations of electrochemical cell analyzers, which included laboratory tests and field tests on natural gas and diesel-fueled generators. The EPA has reviewed the ETV test results, published additional information, and provided technical input that has been considered in the update of this test method.31.2 This test method contains notes that are explanatory and are not part of the mandatory requirements of the standard.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏
43 条记录,每页 15 条,当前第 2 / 3 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页