5.1 Values obtained by flexural tests can provide information with regard to the bond strength of the particular varnish, in combination with a particular wire, when measured under conditions described in this test method.1.1 This test method covers determination of the bond strength of an electrical insulating varnish when applied to a helical coil. The helical coil can be made from bare aluminum or copper wire or from film or fiber-insulated magnet wire. Helical coils made from bare aluminum or bare copper wire will yield values of bond strength for the varnish when applied to bare metal conductors. The use of film or fiber-insulated magnet wire will show values for that particular combination of insulation and varnish.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 7.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This practice shows the status of coal mine reclamation as outlined by each phase of reclamation that can result in bond release, according to SMCRA and 30 CFR Part 700, et seq (See OSM, Directive Reg-8). This practice is significant to the coal mining community because it provides uniformity of geospatial data pertaining to the reclamation and bond status throughout the United States.Within its area of exclusive jurisdiction, each RA is the authoritative data source (ADS) for coal mining spatial data that it creates and uses to regulate coal mining.This geospatial data standard will help ensure uniformity of data contributed by each RA and assist organizations in efforts to create, utilize, and share geospatial data relative to SMCRA and it will lead to better communications between state, tribal, and federal regulatory offices, the public and industry.Surface coal mining geospatial data, specifically to the status of the reclamation, shall be obtained from state, tribal, or federal regulatory authorities for each SCMO. The coal mining community encompasses all entities directly and indirectly affected by coal mining activities, including industry, environmental groups, the general public, and the government at all levels within the United States. Use of this standard will help create consistent maps and increase understanding of SCMO sites throughout the United States. This standard promotes the creation of well organized and easily accessible surface coal mining data, and it will facilitate better communication between state and federal offices, the public, industry, and environmental groups.In addition to defining the status of individual areas covered by a reclamation bond, use of this standard will identify the changes of the reclamation and bond status to individual mined areas as they change over time.The land reclamation and bond status datasets may appear to be incomplete for some RAs. In some instances the data may not have been compiled.This standard conforms to the definition of a Data Content Standard as promulgated by the U.S. Federal Geographic Data Committee (FGDC). Terminology and definitions for identifying geographical features and describing the data model has been adopted from the FGDC Spatial Data Transfer Standard (ANSI INCITS 320-1998 (R2003)) and the FGDC Framework Data Content Standard (FGDC Project 1574-D) and other geographic area boundaries.Although this standard is written specifically for the coal mining industry, its general purpose and content are applicable to other mining operations.1.1 This practice covers the minimum elements for the accurate location and description of geospatial data for defining the land reclamation and performance bond status of a permitted coal mine.1.1.1 Hereafter, reference to bond status means performance bond status.1.1.2 This practice addresses coal mining geospatial boundary data relative to the Surface Mining Control and Reclamation Act of 1977 (SMCRA), including interim and permanent program lands. This geospatial data shall be obtained from each state, tribal or federal (or combinations thereof) coal mining regulatory authority (RA) authorized under SMCRA to regulate surface coal mining operations (SCMO). Each RA shall be the authoritative data source (ADS) for coal mining geospatial data.1.1.3 As used in this practice, the land reclamation status of the surface areas of a permitted coal mining operation represents the area where coal removal and reclamation and related supporting activities has occurred, is occurring, or is planned and authorized by the RA within a defined SCMO.1.1.4 Not all RAs use the same SMCRA bond release phase definitions. For example, SMCRA uses three phases whereas some RAs use four phases.1.1.5 Participation in the compilation of spatial data is not uniform across RAs, which may affect completeness, both in terms of spatial data and associated attributes. For some RAs, this standard may not be applicable because features described herein do not occur within their area of responsibility.1.1.6 This standard is one of several in development related to SMCRA approved coal mining operations. Also under development is a terminology standard. Initial development of these standards is being done on an individual basis (See Practice D7384), however they may be consolidated to reduce repetition of information between them.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulator limitations prior to use.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.4 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 Seven-wire steel strand is used in pre-tensioned and post-tensioned concrete construction.4.2 0.600 in. [15.24 mm] diameter, Grade 270 seven-wire steel strand is used to make prestressed ground anchors which are often bonded to cement grout.4.3 Manufacturing processes, subsequent handling, and storage conditions may influence the strand bond.4.4 The primary use of this test method is to establish the relative bond strength of 0.600 in. [15.24 mm] seven-wire steel strand.4.5 The relative bond strength is determined by recording the pullout force at a certain displacement of the strand.AbstractThis test method deals with the standard procedures for establishing the relative bond strength of Grade 270 prestressing steel strands of specified diameter in cement grout as used in prestressed ground anchors for evaluating the effects of manufacturing practices on bond strength. The bond strength values obtained shall not be used to design the bond strength of ground anchors that depend on field conditions. This test method is not intended to be used as a bond test for pretensioned concrete applications. The test specimen shall be cut from standard production coils and shall not be wiped or cleaned. Pull test shall be made in accordance with the method.1.1 This test method describes procedures to establish the relative bond strength of 0.600 in. [15.24 mm] diameter, Grade 270 [1860] seven-wire steel strand in cement grout as used in prestressed ground anchors for the purpose of evaluating the effects of manufacturing practices on bond strength.1.2 The bond strength values obtained are not intended to be used to design the bond length of ground anchors that depend on field conditions.1.3 This test method is not intended to be used as a bond test for prestressed concrete applications.1.4 The values stated in either inch-pound or SI units are to be regarded as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

3.1 The different combinations of SMD types, attachment medias, circuit substrates, plating options, and process variation can account for significant variation in test outcome.3.2 The SMD shear strength test is useful to manufacturers and users for determining the bond strength of the component to the membrane switch circuit.1.1 This test method covers the determination of the shear integrity of materials and procedures used to attach surface mount devices (SMD) to a membrane switch circuit.1.2 This test method is typically used to indicate the sufficient cure of conductive adhesive or underfill, or both. In general, this test method should be used prior to encapsulant. This test may also be used to demonstrate the Shear Force with encapsulation.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 The behavior of the bond between concrete and FRP reinforcing bars is an important performance aspect that has been used in material specifications and design standards. This test method serves as a means for uniformly preparing specimens and testing FRP bar-to-concrete bond, and for providing a standard method to calculate, evaluate and report bond strength.5.2 This test method for measuring bond strength by pullout testing is intended for use in laboratory tests in which the principal variable is the size or type of FRP bars.NOTE 1: This test method should not be used to establish design bond values and development lengths for FRP bars embedded in concrete, as it does not represent the state of bond stress observed in concrete flexural members reinforced with FRP bars. See Test Method A944 for a beam-end test configuration, used for determining bond stress in steel bars.5.3 This test method is intended to determine the bond behavior for material specifications, research and development. The bond behavior will be specimen-configuration dependent, which may affect both analysis and design. The primary test result is the bond strength of the specimen to normal weight concrete.5.4 This test method may also be used to determine the conformance of a product or a treatment to a requirement relating to its effect on the bond developed between FRP bar and concrete. The result obtained from this test method should be used only for comparative purposes to compare parameters or variables of bond strength. The method may be used as part of a protocol to establish long-term environmental effects on bond to concrete, including environmental reduction factors for FRP bars embedded in concrete.1.1 This test method covers the determination of the bond strength of fiber-reinforced polymer (FRP) composite bars used as reinforcing bars or pre-stressing tendons in concrete.1.2 Two procedures for casting test specimens are provided. The first procedure aligns the bar with the concrete casting direction. The second procedure aligns the bar’s transverse to the concrete casting direction.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 This practice may be used to determine the storage life of any adhesive where this information is required.4.2 This practice is intended to determine whether the storage life conforms to the minimum specified storage life required of an adhesive by viscosity tests (Procedure A) or by bond strength tests (Procedure B), or by both. It does so by providing results before and after a set of standard conditions that simulate storage life. The determination of what the requirements for percentage of the original property retained or the minimum value for a property is found in the relevant material specification, or as agreed between manufacturer and user.1.1 This practice describes a laboratory method by which the storage life of an adhesive may be measured using viscosity, adhesive strength, or a combination thereof.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 To determine acceptable working life of an adhesive, two procedures are used. This practice is intended to apply to:4.1.1 Self-contained liquid or paste adhesives,4.1.2 Adhesives requiring addition of a catalyst, hardener, filler, thinner, and so forth, or combinations of two or more of these materials just prior to use, and4.1.3 Powdered or flaked adhesives which are dissolved in water or other solvent and are used as liquid or paste adhesives.1.1 This practice covers two procedures applicable to all adhesives having a relatively short working life. It is intended to determine whether the working life conforms to the minimum specified working life of an adhesive required by consistency tests or by bond strength tests, or by both.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

4.1 These test methods are intended to provide information from which applicable design data and specifications are derived for a given anchorage device and for qualifying anchors or anchorage devices.4.2 These test methods shall be followed to ensure reproducibility of the test data.1.1 These test methods cover instructions for making a variety of tests for the strength of the adhesive bond developed between a steel anchor and the surface of a hole in concrete or masonry (including masonry units and mortar joints) and for assessing the effects on such bond of a variety of factors including elevated temperature, fire, moisture, and freezing and thawing action. The specifier or manufacturer shall select those tests that are appropriate for the given anchoring system and intended application.1.2 The adhesive-bonded anchor system refers to a smooth or deformed steel bar or threaded rod, set in a predrilled hole containing chemical bonding compounds. Loads are transferred mainly by the bond of the adhesive both to the anchor and the surrounding elements along the sides of the hole. For anchoring systems made of significantly different materials, these test methods shall be taken as a guideline.1.3 These test methods apply to all adhesives used to bond steel anchors or steel reinforcement bars (rebar) to concrete or masonry. These test methods apply to anchorages used in uncracked concrete or masonry. They do not apply to the use of the anchor in the concrete tension zone. The usual forces applied during the tests are in tension, shear, and under a combination of both tension and shear.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM C952-12 Standard Test Method for Bond Strength of Mortar to Masonry Units (Withdrawn 2018) Withdrawn, Replaced 发布日期 :  1970-01-01 实施日期 : 

3.1 These procedures are useful for research into bond strength of masonry. They are not intended to predict the bond strength of commercial masonry construction. The bond strength in commercially built structures is determined by many factors beyond the characteristics of mortar, masonry units, and the procedures of this test method.Note 1—The crossed-brick couplets method measures a direct tensile strength of the bond between the mortar and masonry unit. It does not determine the flexural strength of the unit mortar assembly. Other test methods may be more appropriate for determining the flexural bond strength between mortar and masonry units. These include Test Methods C1072 and Test Methods E518.1.1 This test method provides two procedures for measuring bond strength of mortar to masonry units: a crossed brick couplet tensile test for evaluating mortar-brick bond strength and a stacked-bond, flexural test for evaluating mortar-concrete block bond strength.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 Values obtained by flexural test provides information with regard to the bond strength of the particular varnish in combination with a particular type of magnet wire, when measured under conditions described in this test method.1.1 This test method covers the determination of the bond strength of an electrical insulating varnish when applied to a twisted coil of film-insulated magnet wire. The use of a particular type of film-insulated wire will show the values for that combination of film coating and varnish.1.2 The values stated in inch-pound units are the standard. The values given in parentheses are for information only.NOTE 1: Although this standard and Method C of IEC 61033 differ in approach or detail, data obtained using either are technically equivalent.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Section 7.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This test method is intended for use in comparing the bond strengths (under the given conditions) of masonry mortars.5.2 This test method could be used, for example, to check one aspect of the quality of mortar products after production, or to indicate the bond potential of a mortar product without requiring the product to be tested in combination with many different units.5.3 This test method uses controlled conditions of fabrication and curing that are not intended to represent field conditions.5.4 This test method uses standard concrete masonry units. Mortars are batched by weight equivalents of volume proportions and are mixed to a prescribed flow. Prisms are constructed using a jig and are bag-cured.5.5 Flexural bond strength determined by this test method shall not be interpreted as the flexural bond strength of a wall (because standard units are not used for wall construction), nor shall it be interpreted as an indication of extent of bond for purposes of water permeability evaluation.1.1 These test methods evaluate the flexural bond strength, normal to the bed joints, of masonry built of manufactured masonry units. Sampling and testing procedures are referenced, and terms are defined. Three different specimen fabrication methods are specified, each for a different purpose:1.1.1 The first method is the “Test Method for Laboratory-Prepared Specimens.” Its purpose is to compare the bond strengths (under the given conditions) of masonry mortars. It could be used, for example, to check the quality of mortar products after production, or to indicate the bond strength (under the given conditions) of a mortar product without requiring the product to be tested in combination with many different units. It is not intended to represent field conditions. It uses standard concrete masonry units. Mortars are batched by weight equivalents of volume proportions and are mixed to a prescribed flow. Prisms are constructed using a jig and are bag-cured.1.1.2 The second method is the “Test Method for Field-Prepared Specimens.” Its purpose is to evaluate the bond strength (under the given conditions) of a particular unit-mortar combination, either for preconstruction evaluation of materials or for quality control purposes during construction. Mortars are batched conventionally, and the flow is not prescribed. Prisms are constructed conventionally (no jig) and are bag-cured.1.1.3 The third method is the “Test Method for Prisms Removed from Existing Masonry.” Its purpose is to evaluate the bond strength of unit-mortar combinations of prisms cut from existing walls.1.1.4 The three methods are not consistent, nor are they intended to be. They are intended to be used for three different purposes. To make this clear, the three methods are presented separately.1.1.5 Appendix X1 suggests two possible criteria for assessing the bond strength values obtained using these test methods. These possible evaluation criteria are given for illustration only and are not mandatory.1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

5.1 This test method determines the tensile strength of concrete near to the prepared surface, which can be used as an indicator of the adequacy of surface preparation before applying a repair or an overlay material.5.2 When the test is performed on the surface of a repair or an overlay material, it determines the bond strength to the substrate or the tensile strength of either the overlay or substrate, whichever is weaker.5.3 The method may also be used to evaluate the adhesive strength of bonding agents.5.4 When the test is performed on the surface of a material applied to the substrate, the measured strength is controlled by the failure mechanism requiring the least stress. Thus it is not possible to know beforehand which strength will be measured by the test. For this reason, the failure mode has to be reported for each individual test result, and tests results are averaged only if the same failure mode occurs.AbstractThis specification covers standard test method for tensile strength of concrete surfaces and the bond strength or tensile strength of concrete repair and overlay materials by direct tension (pull-off method). This test method is suitable for both field and laboratory use to determine one or more of the following: the near-surface tensile strength of the substrate as an indicator of the adequacy of surface preparation before application of a repair or overlay material; the bond strength of a repair or an overlay material to the substrate; and the tensile strength of a repair or overlay material, or an adhesive used in repairs, after the material has been applied to a surface. The following apparatus shall be utilized: core drill; core barrel; steel disk; tensile loading device; and a coupling device. This test shall be performed on the surface of a prepared concrete base before application of a concrete repair overlay material, or on the surface of a concrete repair overlay material after the material has been applied to the prepared concrete surface. The test specimen shall be formed by drilling a shallow core into and perpendicular to the surface of the substrate, and leaving the intact core attached to the concrete. A steel disk shall be bonded to the top surface of the test specimen. A tensile load shall be applied to the steel disk until failure occurs. The failure load and the failure mode shall be recorded and the nominal tensile stress at failure shall be calculated.1.1 This test method is suitable for both field and laboratory use to determine one or more of the following:1.1.1 The near-surface tensile strength of the substrate as an indicator of the adequacy of surface preparation before application of a repair or overlay material.1.1.2 The bond strength of a repair or an overlay material to the substrate.1.1.3 The tensile strength of a repair or overlay material, or an adhesive used in repairs, after the material has been applied to a surface.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏