微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This test method covers the determination of ethylene diamine tetraacetate (EDTA) in soaps and synthetic detergents. Throughout this test method EDTA represents the hydrated disodium salt containing 2 moles of H 21.1 This test method covers the determination of ethylene diamine tetraacetate (EDTA) in soaps and synthetic detergents. Throughout this test method EDTA represents the hydrated disodium salt containing 2 moles of H2O. In the chemical literature this is frequently abbreviated to Na2H2Y4 · 2H2O.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Fluorspar is used as a flux in the steelmaking and glass industries, and in the manufacture of HF.5.2 This test method is intended to be used for compliance with compositional specifications for calcium fluoride content. It is assumed that all who use these procedures will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Appropriate quality control practices must be followed such as those described in Guide E882.1.1 This test method covers the determination of calcium fluoride in acid-grade fluorspar and other types of fluorspar that can be rendered soluble by the procedure described in the test method.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This test method has been evaluated in accordance with Practice E1601 and Guide E1763. Unless otherwise noted in the precision and bias section, the lower limit in the scope of each method specifies the lowest analyte content that may be analyzed with acceptable error (defined as a nominal 5 % risk of obtaining a 50 % or larger relative difference in results on the same test sample in two laboratories).1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method may be used to confirm the stated content of a liquid iron drier soluble in isopropyl alcohol and manufactured for use in the coatings industry. The content determines activity level.1.1 This test method covers the titrimetric determination of iron in liquid iron driers soluble in isopropyl alcohol and utilizes the disodium salt of ethylenediaminetetraacetic acid dihydrate (EDTA).1.2 This test method is limited to the determination of the iron content of a liquid drier that does not contain other drier elements. This method is not applicable to drier blends.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 This test method for the analysis of iron ore concentrates and agglomerates is primarily intended as a referee method to test for compliance with compositional specifications. It is assumed that all who use this test method will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Appropriate quality control practices shall be followed, such as those described in Guide E882.1.1 This test method2 covers the determination of aluminum in iron ores, concentrates, and agglomerates in the compositional range from 0.25 % to 5 % aluminum.NOTE 1: As used in this test method (except as related to the term relative standard deviation), “percent” or “%” refers to mass fraction (mass/mass) of the form g/100 g.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method for the chemical analysis of metals and alloys is primarily intended to test such materials for compliance with compositional specifications. It is assumed that all who use this test method will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.1.1 This test method covers the chemical analysis of magnesium ferrosilicon having chemical compositions within the following limits:Element Composition Range, % Aluminum 2.0 maxCalcium 0.25 to 3.00Carbon 0.50 maxCerium 1.0 maxChromium 0.50 maxMagnesium 2.00 to 12.00Manganese 1.0 maxSilicon 40.00 to 55.00Sulfur 0.025 maxTitanium 0.2 max1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For general precautions to be observed in this test method, refer to Practices E50.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method may be used to confirm the stated calcium or zinc content of pure liquid calcium or zinc driers soluble in toluene-alcohol and manufactured for use by the coatings industry.1.1 This test method covers a titrimetric determination of calcium in liquid calcium driers and zinc in liquid zinc driers that can be dissolved in a toluene-alcohol mixture and utilizes the disodium salt of ethylenediaminetetraacetic acid dihydrate (EDTA).1.2 This test method is not applicable to drier blends.1.3 All cations that can be titrated with EDTA in alkaline media interfere and must not be present in the sample.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏
ASTM D3113-92(1998) Standard Test Methods for Sodium Salts of EDTA in Water (Withdrawn 2005) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏
ASTM D2375-05(2011) Standard Test Method for Manganese in Paint Driers by EDTA Method (Withdrawn 2016) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏
ASTM D2374-05(2011) Standard Test Method for Lead in Paint Driers by EDTA Method (Withdrawn 2016) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
28 条记录,每页 15 条,当前第 1 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页