微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This specification addresses less lethal chemical irritant sprays used by law enforcement, corrections, and other public safety officers.1.2 This specification is limited to duty belt-mounted canisters.1.3 This specification is limited to sprays intended for use on humans.1.4 This specification defines requirements for products containing liquid aerosol Oleoresin Capsicum (OC) spray (that is, pepper spray), Orthochlorobenzalmalononitrile (CS) spray (that is, 2–chlorobenzylidenemalononitrile; CAS #: 2698-41-1), or OC-CS combination spray. The formulation may be delivered as a stream, gel, foam, cone, or vapor.1.5 This specification does not address incendiary devices or “hot gas.”1.6 Products covered by this specification may be flammable or nonflammable.1.7 Products covered by this specification are hazardous substances as defined by 16 CFR 1500.3.1.8 It is intended that the following related practice be used in conjunction with this specification: Practice E3215.1.9 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.9.1 For some quantities in Sections 9, 10, and 11, only SI units are used to be consistent with industry practice.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 918元 / 折扣价: 781 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This practice establishes the certification requirements for less lethal aerosol devices used by law enforcement, corrections officers, and other public safety officers.1.1.1 This practice is intended to be used by certification bodies and by purchasers and suppliers in the procurement of less lethal aerosol devices that meet Specification E3187/E3187M.1.1.2 The performance, testing, labeling, documentation, and reporting requirements for certification are specified in Specification E3187/E3187M.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 Every person who is identified as a PS-RP shall have met the requirements of this guide.4.2 This guide is to be used by individuals and agencies having jurisdiction who wish to identify the minimum training standards for PS-RP.4.3 This guide is only the first level of training for PS-RP personnel, and as such, only establishes the minimum knowledge, skills, and abilities required for a person to perform as a PS-RP.4.4 Nothing in this guide precludes a user of this guide from adding additional requirements for its own members. The US-specific examples are intended to establish a common frame of reference.4.5 This guide by itself is not a training document. It is only an outline of the topics required for training or evaluating a PS-RP, but it can be used to develop a training document or program.4.6 It is up to the training authority to determine the depth or detail of training to meet its needs. Terminologies and requirements for secondary or associated training should be task/specialization-specific—not all operators require all types and levels of training. This guide supports alternatives and subsets of knowledge requirements appropriate to the type of operation, when part of a documented training program according to Specification F3330.4.7 This guide does not stand alone and must be used with the referenced documents to provide the specific information needed by the user.4.8 This guide can be used to evaluate a book or other document to determine if its content meets the necessary topics for training a PS-RP. Likewise, the guide can be used to evaluate an existing training program to see if it meets the requirements of this guide.4.9 The knowledge, skill, and ability requirements presented in the following sections are not presented in any particular order and do not represent a training sequence.1.1 This guide covers the minimum training requirements for public safety remote pilots (PS-RPs) as it relates to their general, field, and search specific knowledge and skills.1.2 This guide does not provide the minimum training requirements for sUAS operations in partially or fully collapsed structures, in or on water, in confined spaces, or underground (such as caves, mines, and tunnels.)1.2.1 Basic remote piloting skills and knowledge are found in Guide F3266.1.3 Personnel trained to this guide are not qualified to operate in leadership positions outside of UAS teams.1.4 Further training may be required before a PS-RP can participate on a particular kind of UAS team, depending on local needs, regulations, or policies of the authority holding jurisdiction (AHJ).1.5 This guide is created without regard to the type of unmanned aircraft system or personal protective equipment that is used by a PS-RP individual. It is expected that all UAS are compliant with Specification F3298 or Specification F2910.1.6 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

4.1 Each Facility Rating Scale (see Figs. 1-7) in this classification provides a means to estimate the level of serviceability of a building or facility for one topic of serviceability and to compare that level against the level of any other building or facility.4.2 This classification can be used for comparing how well different buildings or facilities meet a particular requirement for serviceability. It is applicable despite differences such as location, structure, mechanical systems, age, and building shape.4.3 This classification can be used to estimate the amount of variance of serviceability from target or from requirement for a single office facility or within a group of office facilities.4.4 This classification can be used to estimate the following:4.4.1 Serviceability of an existing facility for uses other than its present use.4.4.2 Serviceability (potential) of a facility that has been planned but not yet built.4.4.3 Serviceability (potential) of a facility for which remodeling has been planned.4.5 Use of this classification does not result in building evaluation or diagnosis. Building evaluation or diagnosis generally requires a special expertise in building engineering or technology and the use of instruments, tools, or measurements.4.6 This classification applies only to facilities that are building constructions, or parts thereof. (While this classification may be useful in rating the serviceability of facilities that are not building constructions, such facilities are outside the scope of this classification.)4.7 This classification is not intended for, and is not suitable for, use for regulatory purposes, nor for fire hazard assessment nor for fire risk assessment.1.1 This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for image to the public and occupants.1.2 Within that aspect of serviceability, each pair of scales, shown in Figs. 1-7, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-7) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-7) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.FIG. 1 Scale A.11.1 for Exterior AppearanceFIG. 1 Scale A.11.1 for Exterior Appearance (continued)FIG. 2 Scale A.11.2 for Public Lobby of BuildingFIG. 2 Scale A.11.2 for Public Lobby of Building (continued)FIG. 3 Scale A.11.3 for Public Spaces Within the BuildingFIG. 3 Scale A.11.3 for Public Spaces Within the Building (continued)FIG. 4 Scale A.11.4 for Appearance and Spaciousness of Office SpacesFIG. 5 Scale A.11.5 for Finishes and Materials in Office SpacesFIG. 6 Scale A.11.6 for Identity Outside the BuildingFIG. 6 Scale A.11.6 for Identity Outside the Building (continued)FIG. 7 Scale A.11.7 for Neighborhood and SiteFIG. 7 Scale A.11.7 for Neighborhood and Site (continued)1.3 The entries in the Facility Rating Scale (see Figs. 1-7) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complimentary to and compatible with Practice E1334. Each requires the other.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

1.1 This specification establishes parameters for the design and manufacture of outdoor fitness equipment as defined in 3.1.30.1.2 It is intended that these fitness products will be used in an unsupervised outdoor setting or environment and will be permanently anchored.1.2.1 It is the intent of this specification to only specify requirements for outdoor fitness equipment and its installation and not the design of the facility or grounds on which the products are to be installed.1.3 The specifications set forth in this standard are intended to minimize the likelihood of serious injuries.1.3.1 The specifications set forth in this standard are for outdoor fitness equipment intended for use in an unsupervised setting by individuals age 13 and older.1.4 The values stated in SI (metric) units are to be regarded as standard. The values in parentheses are for information only.1.5 General Measures, Tolerances, and Conversions: 1.5.1 The general tolerances for this specification (unless otherwise specified) are as follows:Dimension ToleranceX mm (X in.) ± 13.0 mm (0.5 in.)X.X mm (X.X in.) ±1.3 mm (0.05 in.)X.XX mm (X.XX in.) ±.0.130 mm (0.005 in.)1.5.2 These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.1.6 This standard is to be used in conjunction with Test Methods F2571 and Specification F2276. If a design or installation concern is not addressed in this specification then the applicable requirements of Specification F2276 shall be used.1.6.1 This standard takes precedence over Specification F2276 and Test Methods F2571 in areas that are addressed in this document.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 843元 / 折扣价: 717 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification prescribes requirements for demonstrating that a building's location provides a minimal level of access to public transit that allows occupants to travel to places of employment and to run typical errands. It is intended to facilitate the decision-making process for selection of a building site that provides opportunities for occupants to use public transit. It specifies a single indicator regarding the environmental performance related to a building's location, and for evaluating whether a building is located in such a way as to minimize the impacts associated with occupants' travel.1.1 This specification provides requirements for demonstrating that a building’s location provides a minimal level of access to public transit such that building occupants can rely on public transit to travel to places of employment and to run typical errands.1.2 This specification addresses a single indicator regarding the environmental performance related to a building’s location. It provides one option for evaluating whether a building is located in such a way as to minimize the impacts associated with occupants’ travel.NOTE 1: The indicator in and of itself is insufficient to imply any level of “sustainability” for the building or the neighborhood. Similarly, a building’s failure to meet this specification does not necessarily signify a lack of sustainability. Other indicators may be more appropriate for that building or region; those indicators are outside the scope of this specification.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
30 条记录,每页 15 条,当前第 1 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页