This specification covers pressure-sensitive tapes of film, paper, and cloth types, with applications in packaging, box closure, and sealing. Covered in this specification are five types of tape: waterproof, weather-resistant, polyester-backed tape (Type I), water-resistant polyester-backed tape (Type II), water-resistant polypropylene-backed tape (Type III), water-resistant woven-cloth-backed tape (Type IV), and weather-resistant paper-backed tape. The tape shall be manufactured with film, paper, or cloth backing, coated with a smooth and uniformly distributed layer of pressure-sensitive water-insoluble adhesive. The tape shall be in wound into rolls on cores of paper fiber or plastic and shall be free from defects, with the edges clean, straight, and unbroken. Tests for adhesion, break strength, tear resistance, thickness, water-penetration rate, water solubility, water-vapor transmission rate, and weathering shall be performed and shall conform to the requirements specified.1.1 This specification covers film, paper, and cloth pressure-sensitive tapes used for box closure and sealing.1.2 The values stated in either inch-pound or SI units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently, without combining values in any way.1.3 The following safety hazards caveat pertains only to the test methods portion, Section 14, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 This recommended practice is intended to provide information on the storage, mixing, handling, and application of polysulfide based sealants. Tooling and equipment requirements for the satisfactory application of the sealants to joints in tactical shelters are also provided.1.1 This practice covers the procedures for sealing rigid wall tactical shelters. It outlines the techniques for the storage, mixing, handling, and application of polysulfide based sealants.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This provisional test method covers the determination of maximum specific gravity of loose bituminous mixtures, as defined in Terminology E 1547, by the vacuum sealing method.1.2 This method can be used with 100 and 150 mm diameter compacted bituminous laboratory and field specimens.1.3 The bulk specific gravity of the compacted bituminous mixtures may be used in calculating the unit weight of the mixture.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.Note 1—Provisional standards require only subcommittee consensus and are published for a limited time of two years. The provisional process was used because of the immediate need for this method to be used in testing pavement mixtures with open graded design, mixtures that readily absorb water and mixtures that allow water to rapidly penetrate and drain out.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

1.1 This provisional test method covers the determination of maximum specific gravity of and density of uncompacted bituminous paving mixtures at 25°C (77°F).1.2 The values stated in SI units are to be regarded as the standard. The other units given may be approximate and are given to help the user interpret units on available standard equipment used with this provisional test method.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.Note 1—Provisional standards require only subcommittee consensus and are published for a limited time of two years. The provisional process was used because agencies and private organizations have an immediate need for a method that will save time and accurately reduce water absorption by absorptive mixes, eliminating the need for post vacuum "dry back" correction and stripping. This method provides a quick way to test loose bitminous mixtures for maximum specific gravity.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 The inspection, testing, and repair of sewer pipe joints is a practice that can assist in maintaining and optimizing sewer performance. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. The method selected should utilize environmentally safe grout and minimize the disruption of traffic.4.2 This practice serves as a means to inspect, test, and seal sewer pipe joints, having selected the appropriate chemical grouts, using the packer method. Television inspection and joint testing are used to identify sewer line conditions, defective joints, and document the repairs undertaken. Instruction on joint sealing, if necessary, is then detailed, using pressure injection into the soils encompassing the pipe joint with a chemical grout (chemical sealing material).4.3 This practice should not be used for longitudinally cracked pipe, severely corroded pipe, structurally unsound pipe, flattened, or out-of-roundpipe. In areas with high groundwater pressure, greater than 10 psi (68.9 ksi) at the test point, consult equipment manufacturers.1.1 This practice describes the procedures for testing and sealing individual sewer pipe joints with appropriate chemical grouts using the packer method. Sewer systems shall include sanitary, storm, and combined and their appurtenances. Chemical grouting is a soil sealing process, which seals the voids within the soil surrounding the exterior of the pipe at the point of leakage. Chemical grouting is not considered a structural repair.1.2 This practice applies to sewers 6 in. to 42 in. (18 cm to 107 cm) in diameter. Larger diameter pipe may be grouted with specialized packers or man entry methods. Host pipe interior surfaces must be adequate to create an effective seal for the packer elements.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 Worker safety training should include reviewing the hazards associated with hoses, pumps, tanks, couplers, compressors, bottles, motors, and all other related application apparatus. Additional safety considerations including safely handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 Seams in some sheet resilient flooring are sealed to prevent openings from forming between cut edges and prevent penetrations of dirt, liquids, etc., into the seams.1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet resilient flooring sealed with liquid seam sealers.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method quantifies the water absorption characteristics of cellular elastomeric gaskets and sealing materials. It is a test that enables the specifier to exercise engineering judgment in the selection of materials.1.1 This test method covers cellular elastomeric compounds that are manufactured in preformed shapes such as gaskets, to be used as compression seals for glazing purposes and as sealing materials in other applications within the building construction sector.1.2 The values stated in SI units are to be regarded as the standard. The values given in U.S. customary units in parentheses are provided for information purposes only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM F30-96(2017) Standard Specification for Iron-Nickel Sealing Alloys Active 发布日期 :  1970-01-01 实施日期 : 

This specification covers the characteristics and requirements for iron-nickel alloys intended primarily for sealing to glass in electronic applications. The alloys shall conform to chemical composition, surface finish, temper, grain size, and thermal expansion requirements as stated herein.1.1 This specification covers iron-nickel alloys that are intended primarily for sealing to glass in electronic applications.NOTE 1: Some of these alloys may be used for sealing to ceramics, but this specification in its present form is not intended to cover material for metal-to-ceramic seals.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The hazard statement pertains only to the test method sections, Sections 10 and 12.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 This practice is a screening tool and should be used in conjunction with other more accurate real-time load-measuring techniques.5.2 This practice covers the use of PIF, which is available in several load ranges. This practice also covers the use of a manual or automatic scanning device to read indicated load.5.3 Limitations include those applications in which the PIF may be kinked, twisted, or buckled. PIF does not withstand elevated temperature, low temperature, or fluid aging and does not take into account any relaxation of bolts, gasket materials, or flange twisting, as it provides only the maximum attained pressure.1.1 This practice covers a standard means for measuring initial static sealing pressure in transportation applications.1.2 It uses a pressure-indicating film (PIF) that will record the maximum load imprint of the seal-to-flange interfaces. The imprints will vary in intensity based on load across and along the interface.1.3 These imprints can be used to determine if initial load on the gasket is adequate to attain a seal. These imprints may also indicate correct bolt torque sequence. These imprints may also be used to determine if the mating surface waviness or local flatness meets gasket requirements. Roughness is rarely found by PIFs because peak-to-peak wavelengths are too short. PIF is very good at finding waviness (peak to peak > 2.5 mm) and local flatness dips. PIFs provide an approximation of maximum pressures, and do not take into account relaxation of the joint after the torque sequence. Other methods involving dynamic measurement should be used if flange loading after relaxation is desired.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

Static seal failures are predominately due to incompatibility with media, degradation by temperature extremes, and extrusion stress. This test method may be used for relative performance evaluation screening, and is normally the second stage of the screening process after immersion testing in accordance with Test Method E 1068.This test method shows relative performance of materials under the combined effects of temperature, pressure, and extrusion stress. It does not necessarily correlate with actual service conditions. This test method is not intended to include the effect of test media.A variety of test parameter combinations are provided so that evaluations can be made for a specific application.This test method uses standard O-rings as test specimens.1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures.1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068.1.3 The test fluid is distilled water.1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.