5.1 Building products made with tapes are often used for applications for which Test Method E84 is used for compliance with building, life safety code or mechanical code requirements. This practice describes, in detail, specimen mounting procedures for tapes.5.2 Codes are often silent with regard to testing tapes for the assessment of flame spread and smoke development as surface burning characteristics. This practice describes specimen preparation and mounting procedures for such materials and products.5.3 The material shall be representative of the materials used in actual field installations.5.4 The limitations for this procedure are those associated with Test Method E84.1.1 This practice covers a procedure for specimen preparation and mounting when testing tapes to assess flame spread and smoke development as surface burning characteristics using Test Method E84. Tapes are to be tested in full coverage as applied to fiber cement board as described in Test Method E84.1.2 This practice applies to any tape intended for various uses within buildings.1.3 Testing is conducted in accordance with Test Method E84.1.4 This practice does not provide pass/fail criteria that can be used as a regulatory tool.1.5 This practice is not for system evaluation. It is for the comparison of the materials only.1.6 Use the values stated in inch-pound units as the standard, in referee decisions. The values in the SI system of units are given in parentheses, for information only; see IEEE/ASTM SI-10 for further details.1.7 This fire standard cannot be used to provide quantitative measures.1.8 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.1.9 This standard gives instructions on specimen preparation and mounting, but the fire-test-response method is given in Test Method E84. See also Section 9.1.10 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes shall not be considered requirements of the standard.1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.12 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 加购物车
5.1 Site-fabricated stretch systems used as interior finish are evaluated with Test Method E84 to comply with building, fire, or life safety code requirements. This practice describes specimen preparation and mounting procedures for such materials and systems.5.2 The limitations for this procedure are those associated with Test Method E84.5.3 Additional Limitations—This practice does not apply to test systems that cannot be used to produce self-supporting specimens. If the test specimen is not self-supporting, further guidance can be found in Annex A4 of Test Method E84.5.4 This practice shall not apply to vinyl stretch ceiling materials, which are covered by Practice E2599.1.1 This practice describes procedures for specimen preparation and mounting when testing a site-fabricated stretch system to assess flame spread and smoke developed as surface-burning characteristics using Test Method E84.1.2 Testing is conducted with Test Method E84.1.3 This practice does not provide pass/fail criteria that can be used as a regulatory tool.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. See IEEE/ASTM SI-10 for further details.1.5 This fire standard cannot be used to provide quantitative measures.1.6 Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests. Fire testing involves hazardous materials, operations, and equipment. This standard gives instructions on specimen preparation and mounting, but the fire-test-response method is given in Test Method E84. See also Section 10.1.7 This practice shall not apply to vinyl stretch ceiling materials, which are covered by Practice E2599.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes shall not be considered requirements of the standard.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 加购物车