1.1 This specification covers asphalt roofing in sheet form, 36 in. (914 mm) in width, or other widths agreed upon between the purchaser and the supplier, composed of asphalt-saturated organic felt with approximately half the width of the weather side coated with asphalt and surfaced with mineral granules, for use as a cap sheet in the construction of built-up roofs.1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.>
1.1 This specification covers asphalt roofing in sheet form, composed of organic roofing felt, saturated with asphalt and coated on both sides with an asphaltic compound which may or may not contain mineral stabilizer, and surfaced with powdered talc, mica, or other fine mineral matter to prevent sticking.1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.>
1.1 This specification covers asphalt roofing in sheet form, in widths as agreed upon by the purchaser and the seller, composed of asphalt-saturated organic felt coated on both sides with asphalt and surfaced on the weather side with mineral granules, except for any selvage.1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.1 This test method, known as the guarded hot box method, covers the measurement of the steady-state thermal transfer properties of panels. In distinction to Test Method C177, which is primarily applicable to homogeneous samples, the guarded hot box method provides for the evaluation of thermal performance of building assemblies. This test method is suitable for building construction assemblies, building panels, and other applications of nono-homogeneous specimens at similar temperature ranges. It may also be used for homogeneous specimens. 1.2 This test method may be applied to any building construction for which it is possible to build a reasonably representative specimen of size appropriate for the apparatus. Note 1-A calibrated hot box, Test Method C976, may also be used for the described measurements and may prove more satisfactory for testing assemblies under dynamic conditions (nonsteady-state) and to evaluate the effects of water migration and air infiltration. The choice between the calibrated or the guarded hot box should be made only after careful consideration of the contemplated use. 1.3 In applying this test method, the general principles outlined must be followed; however, the details of the apparatus and procedures may be varied as needed. 1.3.1 The intent of this test method is to give the essential principles and the general arrangement of the apparatus. Any test using this apparatus must follow those principles. The details of the apparatus and the suggested procedures that follow are given not as mandatory requirements but as examples of this test method and precautions that have been found useful to satisfy the essential principles. 1.3.2 Persons applying this test method shall be trained in the methods of temperature measurement, shall possess a knowledge of the theory of heat flow, and shall understand the general requirements of testing practice. 1.3.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 2-While various units may be found for thermal properties, the International System of units is used exclusively in this test method. For conversion factors to inch-pound and kilogram-calorie systems, see Table 1.