微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

5.1 Hydroxyl is an important functional group and knowledge of its content is required in many intermediate and end use applications. This test method is for the determination of primary and secondary hydroxyl groups and can be used for the assay of compounds containing them.5.2 This test method has the following advantages over other hydroxyl number methods: It is rapid (10 min), pyridine-free, ambient temperature, small sample size, applicable to extremely low hydroxyl numbers (<1), and is amenable to automation.1.1 This test method covers the determination of hydroxyl groups attached to primary and secondary carbon atoms in aliphatic and cyclic compounds and phenols from 0.5 to 367 hydroxyl number. It is not suitable for determination of hydroxyl groups attached to tertiary carbon atoms. This test method is applicable to polyacetals, temperature sensitive materials, high solids polymer polyols, and rigid polyols. Other available test methods listed in Note 1 are not suitable for many of the sample types listed above.1.1.1 This test method is currently recommended for neutral refined products. Successful application has been made, however, to some in-process samples that contain an excess of acidic species. Proper validation must be performed, of course, to show that the acidic species either does not interfere, or that the acidic species interference has been obviated.NOTE 1: Other methods for determination of hydroxyl groups are given in Test Methods D817, D871, D4252, D4273, D4274, E222, E326, and E335.1.2 The Limit of Detection (LOD) is 0.18 units and the Limit of Quantitation (LOQ) is 0.59 units. Unit = hydroxyl number (OH#).NOTE 2: LOD and LOQ were calculated using Standard deviations from 14.1.2.1.1.3 Review the current appropriate Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 The following applies for the purposes of determining the conformance of the test results using this test method to applicable specifications. Results shall be rounded off in accordance with the rounding-off method of Practice E29.1.6 This standard does not purport to address all of the safety concerns, if any, associated, with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards see Section 9.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 An estimate of TA purity can be determined by titrating with KOH. As an index of TA purity, the acid number can be used as a guide in the quality control of TA production.1.1 This test method covers the determination of acid number in terephthalic acid (TA) by automatic potentiometric titration. As the index of TA purity, acid number is usually within 674 to 676 mg KOH/g.1.2 In determining the conformance of the test results using this method, results shall be rounded off in accordance with the rounding-off method of Practice E29.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 The most common anionic surfactants presented in this test method are used widely in synthetic detergents and other household cleaners. Current analysis of the active matter in these anionic surfactants involves the two-phase aqueous/chloroform titration with a mixed indicator, organic dyes such as disulphine blue/dimidium bromide (see Test Method D3049), and methylene blue (see Test Method D1681). This test method eliminates the use of hazardous chloroform, the use of which is restricted for environmental and toxicological reasons.5.2 This test method also describes the titration of various ratio blends of sodium alkylbenzene sulfonate and sodium xylene sulfonate. Active matter content in these blends is attributable directly to sodium alkylbenzene sulfonate. Therefore, the presence of various amounts of sodium xylene sulfonate in these blends does not interfere with the determination of percent actives.1.1 This test method is based on a potentiometric titration of common anionic surfactants and blends of anionic surfactant with a hydrotrope. This test method solely is intended for the analysis of active matter in the following surfactants: alcohol ether sulfate, alpha olefin sulfonate, alkylbenzene sulfonic acid, alcohol sulfate, sodium alkylbenzene sulfonate/sodium xylene sulfonate blend (5:1), sodium alkylbenzene sulfonate/sodium xylene sulfonate blend (16:1), and sodium alkylbenzene sulfonate/sodium xylene sulfonate blend (22:1). It has not been tested for surfactant formulations.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

Anionic surfactants, such as those listed in 1.1, commonly are used in detergent formulations. Their acceptability for use depends on their purity. Sulfate content, as measured by this test method, can be used to estimate the purity of an anionic surfactant under test.1.1 This test method describes a potentiometric titration procedure for determining the inorganic sulfate content of surfactants. It is intended for the analysis of -olefin sulfonates, alkane sulfonates, alcohol sulfates, alcohol ether sulfates, alkylbenzenesulfonates, and the like.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

5.1 This test method is intended to be used as a referee method for compliance with compositional specifications for manganese content. It is assumed that all who use these procedures will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Appropriate quality control practices must be followed such as those described in Guide E882.1.1 This test method covers the determination of manganese in manganese ore in the range from 15 % to 60 %.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 This test method provides a simpler means for the determination of the hydroxyl content of cellulose esters than the preparation and measurement of the carbanilate derivative described in Test Methods D817 and D871.4.2 The hydroxyl content is an important indicator of solubility and reactivity.1.1 This test method covers a procedure for determining the percent hydroxyl on cellulose esters by potentiometric titration. The typical range of percent hydroxyl measured is 0.7 to 10.0 %.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 A knowledge of water extractable inorganic halides in oil is important when deciding whether or not the oils need desalting. Excessive halide, especially in crude oil, frequently results in higher corrosion rates in refining units.1.1 This test method covers the determination of salt in crude oils. For the purpose of this test method, salt is expressed as % (m/m) NaCl (sodium chloride) and covers the range from 0.0005 % to 0.15 % (m/m).1.2 The limit of detection is 0.0002 % (m/m) for salt (as NaCl).1.3 The test method is applicable to nearly all of the heavier petroleum products, such as crude oils, residues, and fuel oils. It may also be applied to used turbine oil and marine diesel fuel to estimate seawater contamination. Water extractable salts, originating from additives present in oils, are codetermined.1.4 The values stated in SI units are to be regarded as the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 702元 / 折扣价: 597 加购物车

在线阅读 收 藏
22 条记录,每页 15 条,当前第 2 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页