AS 2054-1977 Spirit levels for use in precision engineering 被代替 发布日期 :  1977-09-01 实施日期 : 

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

4.1 Trace amounts of water may be detrimental to the use of chlorine in some applications. The amount of water in the chlorine must be known to prevent problems during its use.1.1 This test method is designed for the on-line determination of the content of water in liquid chlorine in the concentration range of 0.5 to 15 mg/kg (ppm).1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.1.3 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7 and Note 3.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

CSA Preface This is the first edition of CAN/CSA-C61000-2-12, Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems, whi

定价: 1001元 / 折扣价: 851

在线阅读 收 藏

CSA Preface This is the second edition of CAN/CSA-C61000-2-2, Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems, which i

定价: 1001元 / 折扣价: 851

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

In geotechnical, hydrologic, and waste-management investigations, it is frequently desirable, or required, to obtain information concerning the presence of ground water or other liquids and the depths to the ground-water table or other liquid surface. Such investigations typically include drilling of exploratory boreholes, performing aquifer tests, and possibly completion as a monitoring or observation well. The opportunity exists to record the level of liquid in such boreholes or wells, as the boreholes are being advanced and after their completion.Conceptually, a stabilized borehole liquid level reflects the pressure of ground water or other liquid in the earth material exposed along the sides of the borehole or well. Under suitable conditions, the borehole liquid level and the ground-water, or other liquid, level will be the same, and the former can be used to determine the latter. However, when earth materials are not exposed to a borehole, such as material which is sealed off with casing or drilling mud, the borehole water levels may not accurately reflect the ground-water level. Consequently, the user is cautioned that the liquid level in a borehole does not necessarily bear a relationship to the ground-water level at the site.The user is cautioned that there are many factors which can influence borehole liquid levels and the interpretation of borehole liquid-level measurements. These factors are not described or discussed in this test method. The interpretation and application of borehole liquid-level information should be done by a trained specialist.Installation of piezometers should be considered where complex ground-water conditions prevail or where changes in intergranular stress, other than those associated with fluctuation in water level, have occurred or are anticipated.1.1 This test method describes the procedures for measuring the level of liquid in a borehole or well and determining the stabilized level of liquid in a borehole.1.2 The test method applies to boreholes (cased or uncased) and monitoring wells (observation wells) that are vertical or sufficiently vertical so a flexible measuring device can be lowered into the hole.1.3 Borehole liquid-level measurements obtained using this test method will not necessarily correspond to the level of the liquid in the vicinity of the borehole unless sufficient time has been allowed for the level to reach equilibrium position.1.4 This test method generally is not applicable for the determination of pore-pressure changes due to changes in stress conditions of the earth material.1.5 This test method is not applicable for the concurrent determination of multiple liquid levels in a borehole.1.6 The values stated in inch-pound units are to be regarded as the standard.1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.