3.1 The significance of the LCA method is that it is a comprehensive technique for taking into account all relevant monetary values over the project design life and provides a measure of the total cost of the material, system, or structure.3.2 The LCA method can be effectively applied in both the preconstruction and bid stages of projects. After bids are taken, real costs can be used instead of estimates.1.1 This practice covers procedures for least cost (life cycle) analysis (LCA) of materials, systems, or structures proposed for use in the construction of concrete culvert, storm sewer, and sanitary sewer systems.NOTE 1: As intended in this practice, examples of analyses include, but are not limited to the following: (1) materials-pipe linings and coatings, concrete wall thicknesses, cements, additives, etc.; (2) systems-circular pipe, box sections, multiple lines, force mains, etc.; and (3) structures-wet and dry wells, pump and lift stations, etc.1.2 The LCA method includes costs associated with planning, engineering, construction (bid price), maintenance, rehabilitation, replacement, and cost deductions for any residual value at the end of the proposed project design life.1.3 For each material, system, or structure, the LCA method determines in present value constant dollars, the total of all initial and future costs over the project design life, and deducts any residual value.1.4 Major factors in the LCA method include project design life, service life, and relevant interest and inflation rates.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 590元 加购物车
This specification covers ductile iron gravity sewer pipe centrifugally cast with push-on joints. This also covers trench load design procedures for both cement-lined pipe and flexible-lined pipe. Maximum depths of cover tables are included for both types of linings. Each pipe shall be subjected to a hydrostatic test and maybe performed either before or after the outside coating and inside coating have been applied, but shall be performed before the application of cement-mortar lining or of a special lining. The standard acceptance tests and additional control tests shall also be performed.1.1 This specification covers 4 to 64 in. ductile iron gravity sewer pipe, centrifugally cast, with push-on joints. This specification may be used for pipe with other types of joints, as may be agreed upon at the time of purchase.1.2 This specification covers trench load design procedures for both cement-lined pipe and flexible-lined pipe. Maximum depth of cover tables are included for both types of linings.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 843元 加购物车
3.1 This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner’s representative, or authorized inspectors for installation method specification and for contractors to refer to during installations of chemical grout for manhole sealing.1.1 This practice covers proposed selection of materials, installation techniques, and inspection required for sealing manholes using chemical grout. Manholes or sections of manholes with active leaks shall be repaired. Manholes to be grouted are of brick, block, cast-in-place concrete, precast concrete, or fiberglass construction. Manholes or sections of manholes with active leaks will be designated by the engineer, owner’s representative, or authorized inspector, for manhole grouting.1.2 The contractor shall be responsible for furnishing all labor, supervision, materials, equipment, and inspection follow-up required for the completion of chemical grouting of manhole defects in accordance with the contract documents.1.3 Materials, additives, mixture ratios, and procedures utilized for the grouting process shall be in accordance with manufacturer’s recommendations and shall be appropriate for the application.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 加购物车
4.1 Hydraulic cleaning methods include equipment that uses water and water velocity to clean the invert and walls of the vitrified clay sewer pipe.4.2 The practice of high-velocity sewer cleaning is best described as a hydraulic cleaning method that uses water pressure to remove obstructions and deposits in sewers or storm drains.4.3 There are different configurations of high-velocity sewer cleaning machines. These units have the capability of generating variable water pressures up to 3500 psi (24 MPa) and variable flow rates of 50-125 gal per min (gpm) (180-473 L per min).4.4 The water tank capacity on these units varies from 1000-1500 gal (3785-5678 L).4.5 The hose lengths vary between 500 and 1000 ft (152 and 305 m) in length with a diameter of 3/4- 11/4 in. NPT.4.6 There are number of different nozzles and tools that may be used during the cleaning process.4.7 Some high-velocity sewer cleaners have a vacuum conveyance system that use large fans or positive displacement vacuum pumps for material removal capabilities. With this type of system, material can be vacuumed from the manhole into a debris tank as it is brought back with the jet or tool and taken to a disposal area. These systems can be either trailer or truck mounted and are generally known as combination machines.4.8 The Occupational Safety and Health Administration (OSHA) has set guidelines for the safe removal of hazardous and nonhazardous substances as stated in OSHA Section 5 of Public Law 91-596; OSHA 29 USC 654; 29 CFR 1910.120; as well as DOT CFR Parts 106-7, 171-180, and 390-397.1.1 This practice covers the personnel requirements, operator training, operating procedures, and recommended equipment performance/design for the proper operation of pressure water-jet cleaning and cutting equipment as normally used by municipalities and contractors tasked with operations, maintenance, cleaning, and pre-rehabilitation cleaning work of vitrified clay mainline sewer pipe.1.2 The term “high-pressure water jetting” covers all water jetting, including the use of jets and hydromechanical tooling at pressures above 2000 psig (0.69 MPa).1.3 This practice covers the “high-pressure water jetting” of vitrified clay pipe and should not be applied to other pipe and pipe lining materials without evaluating the recommended cleaning procedure from the manufacturer to avoid damage.1.4 Units—The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 加购物车
This specification covers requirements and test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of poly (vinyl chloride) (PVC) sewer and drain pipe and fittings. The pipe shall be made from virgin cell 12164 with a certain minimum tensile strength, 12454 or 12454 poly(vinyl chloride) compounds. The fittings shall be made from virgin poly(vinyl chloride) compounds of cell classification PVC 12454, PVC 12454, or PVC 13343. Compounds that have different cell classification because one or more properties are superior to those of the specified compounds are also acceptable. In order to determine the overall performance of the pipes and fittings, the following tests shall be done: flattening test, joint tightness test, and perforation test. The pipe and fittings shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects. The pipe shall be as uniform as commercially practical in color, opacity, density, and other physical properties.1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of poly(vinyl chloride) (PVC) sewer and drain pipe and fittings. Perforated pipe is also covered; the joint tightness test is not applicable for perforated pipe. A form of marking to indicate compliance with this specification is also included.1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.4 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.