微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This standard defines the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the numerical model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the peak spatial average SAR in a cubical volume and to validate the correct implementation of the FDTD simulation software. This document does not recommend specific SAR limits since these are found elsewhere, e.g., in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) or in IEEE C95.1.

定价: 97元 / 折扣价: 83

在线阅读 收 藏

This document specifies protocols and test procedures for the reproducible and repeatable measurement of the conservative exposure peak spatial average SAR (psSAR) induced inside a simplified model of the head and the body by radio-frequency (RF) transmitting devices, with a defined measurement uncertainty. These protocols and procedures apply to a significant majority of the population, including children, during the use of hand-held and body-worn wireless communication devices. These devices… read more include single or multiple transmitters or antennas, and are operated with their radiating structure(s) at distances up to 200 mm from a human head or body. This document is employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, operating in conjunction with other RF-transmitting, non-transmitting devices or accessories (e.g. belt-clips), or embedded in garments. The applicable frequency range is from 4 MHz to 10 GHz. Devices operating in the applicable frequency range can be tested using the phantoms and other requirements defined in this document. The device categories covered include, but are not limited to, mobile telephones, cordless microphones, and radio transmitters in personal, desktop and laptop computers, for multi-band operations using single or multiple antennas, including push-to-talk devices. This document can also be applied for wireless power transfer devices operating above 4 MHz. This document does not apply to implanted medical devices. read less

定价: 190元 / 折扣价: 162

在线阅读 收 藏

This part of IEC/IEEE 62704 establishes the concepts, techniques, validation procedures, uncertainties and limitations of the finite difference time domain technique (FDTD) when used for determining the peak spatial-average and whole-body average specific absorption rate (SAR) in a standardized human anatomical model exposed to the electromagnetic field emitted by vehicle mounted antennas in the frequency range from 30 MHz to 1 GHz, which covers typical high power mobile radio products and… read more applications. This document specifies and provides the test vehicle, human body models and the general benchmark data for those models. It defines antenna locations, operating configurations, exposure conditions, and positions that are typical of persons exposed to the fields generated by vehicle mounted antennas. The extended frequency range up to 6 GHz will be considered in future revisions of this document. This document does not recommend specific peak spatial-average and whole-body average SAR limits since these are found in other documents, e.g. IEEE C95.1-2005, ICNIRP (1998). read less

定价: 159元 / 折扣价: 136

在线阅读 收 藏

The scope of this project is to describe the concepts, techniques, models, validation procedures, uncertainties and limitations of the finite-difference time-domain technique (FDTD) when used for determining the spatial-peak specific absorption rate (SAR) in standardized human anatomical models.These models are exposed to personal wireless devices, e.g. mobile phones. It recommends and provides guidance on modeling of personal wireless devices and provides benchmark data for simulation of such models. It defines model contents and provides guidance on meshing and test positions at the anatomical models. This document does not recommend specific SAR values since these are found in other documents, e.g., IEEE C95.1 and IEEE C95.1a.

定价: 58元 / 折扣价: 50

在线阅读 收 藏

This part of IEC/IEEE 62209 specifies measurement protocols and test procedures for the reproducible measurement of peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of a human head or body by radio-frequency (RF) transmitting devices, with a specified measurement uncertainty. Requirements are provided for psSAR assessment using vector measurement-based systems. A vector measurement-based system may have different technical solutions such as scanning system… read more or an array system. Such systems determine the psSAR by three-dimensional (3D) field reconstruction within the volume of interest in accordance with the requirements herein for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for the psSAR assessments covering a significant majority of people including children during use of wireless communication devices operated in close proximity to the head or body. This document is applicable to wireless communication devices intended to be used at a position near the human head or body at distances up to and including 200 mm. This document can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 300 MHz to 6 GHz. The system validation procedures provided within this document cover frequencies from 300 MHz to 6 GHz. The wireless communication device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop and laptop devices, multi-band, multi-antenna, and push-to-talk devices. read less

定价: 173元 / 折扣价: 148

在线阅读 收 藏
186 条记录,每页 15 条,当前第 13 / 13 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页