This standard provides recommendations to protect personnel in military environments against established adverse health effects associated with exposure to electric, magnetic, and electromagnetic fields, induced and contact current, and contact and arcing voltages over the frequency range of 0 Hz to 300 GHz. The recommendations, expressed as dosimetric reference limits (DRLs) and exposure reference levels (ERLs), incorporate safety factors that address uncertainties such as uncertainties in the… read more experimental data, measurement uncertainties, and differences in threshold variability between individuals, so as to establish an appropriate margin of safety. The DRLs are expressed in terms of in situ electric field strength, specific absorption rate (SAR), and incident power density. The ERLs are expressed in terms of environmental exposure fields and power densities. In the case of contact current, however, only ERLs are provided. The DRLs and ERLs are intended to protect against established adverse human health effects associated with electrostimulation of tissue and partial and whole-body heating, but may not protect against electromagnetic interference (EMI) with implanted medical devices. This standard does not apply to exposure of informed volunteers in medical or scientific research studies subject to approval by institutional review boards for the use of human subjects, nor does it include exposure assessment techniques, risk management/safety program procedures, warning sign design, procedures for medical treatment of suspected overexposures, nor assessment of hazards associated with exposure of ordnance, fuel, or electro-explosive devices. read less

定价: 132元 / 折扣价: 113

在线阅读 收 藏

This International Standard specifies computational procedures using Finite-Difference Time-Domain (FDTD) and Finite Element Methods (FEM) to assess the peak and spatial-averaged power density relevant to the human exposure of the human head or body from devices operating between 6 GHz and 300 GHz. It applies to devices with radiating structures at distances up to and including 200 mm. This includes but is not limited to mobile phones, tablets, and wearables. This standard provides a… read more conservative estimate of the power density of the exposure of the head or body for a significant majority of persons during normal use of these devices. read less

定价: 0元 / 折扣价: 0

在线阅读 收 藏

The objective of this document is to specify methods to assess human exposure to electromagnetic fields generated by stationary wireless power transfer (WPT) in terms of specific absorption rate (SAR), internal electric fields or current density, and contact currents. The frequency range covered by this document is from 3 kHz to 30 MHz. This document focuses on exposures from inductive WPT systems and specifies: -general compliance assessment procedures; -measurement methods; -computational… read more assessment methods; -assessment combining measurement and computational methods. This document does not consider the immunity of cardiac implantable electrical devices to radiated disturbances from WPT systems. read less

定价: 201元 / 折扣价: 171

在线阅读 收 藏

This document specifies computational procedures for conservative and reproducible computations of power density (PD) incident to a human head or body due to radiofrequency (RF) electromagnetic field (EMF) transmitting devices. The computational procedures described are finite-difference time-domain (FDTD) and finite element methods (FEM), which are computational techniques that can be used to determine electromagnetic quantities by solving Maxwell's equations within a specified computational… read more uncertainty. The procedures specified here apply to exposure evaluations for a significant majority of the population during the use of hand-held and body-worn RF transmitting devices. The methods apply to devices that can feature single or multiple transmitters or antennas, and that can be operated with their radiating part or parts at distances up to 200 mm from a human head or body. This document can be employed to determine conformity with any applicable maximum PD requirements of different types of RF transmitting devices used in close proximity to the head and body, including those combined with other RF transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz. The RF transmitting device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices. The procedures of this document do not apply to PD evaluation of electromagnetic fields emitted or altered by devices or objects intended to be implanted in the body. read less

定价: 160元 / 折扣价: 136

在线阅读 收 藏

This standard specifies the assessment methods to evaluate compliance of stationary and dynamic wireless power transfer systems with electromagnetic human exposure guidelines (external electric and magnetic fields, internal specific absorption rate (SAR), induced electric fields or current density including contact currents). The frequency range of this document is from 1 kHz to 30 MHz.

定价: 160元 / 折扣价: 136

在线阅读 收 藏

This document specifies protocols and test procedures for repeatable and reproducible measurements of power density (PD) that provide conservative estimates of exposure incident to a human head or body due to radio-frequency (RF) electromagnetic field (EMF) transmitting communication devices, with a specified measurement uncertainty. These protocols and procedures apply for exposure evaluations of a significant majority of the population during the use of hand-held and body-worn RF transmitting communication devices. The methods apply for devices that can feature single or multiple transmitters or antennas, and can be operated with their radiating structure(s) at distances up to 200 mm from a human head or body. The methods of this document can be used to determine conformity with applicable maximum PD requirements of different types of RF transmitting communication devices being used in close proximity to the head and body, including if combined with other RF transmitting or nontransmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz. The RF transmitting communication device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices.

定价: 193元 / 折扣价: 165

在线阅读 收 藏

This document specifies protocols and test procedures for the reproducible and repeatable measurement of the conservative exposure peak spatial average SAR (psSAR) induced inside a simplified model of the head and the body by radio-frequency (RF) transmitting devices, with a defined measurement uncertainty. These protocols and procedures apply to a significant majority of the population, including children, during the use of hand-held and body-worn wireless communication devices. These devices… read more include single or multiple transmitters or antennas, and are operated with their radiating structure(s) at distances up to 200 mm from a human head or body. This document is employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, operating in conjunction with other RF-transmitting, non-transmitting devices or accessories (e.g. belt-clips), or embedded in garments. The applicable frequency range is from 4 MHz to 10 GHz. Devices operating in the applicable frequency range can be tested using the phantoms and other requirements defined in this document. The device categories covered include, but are not limited to, mobile telephones, cordless microphones, and radio transmitters in personal, desktop and laptop computers, for multi-band operations using single or multiple antennas, including push-to-talk devices. This document can also be applied for wireless power transfer devices operating above 4 MHz. This document does not apply to implanted medical devices. read less

定价: 190元 / 折扣价: 162

在线阅读 收 藏

This part of IEC/IEEE 62704 establishes the concepts, techniques, validation procedures, uncertainties and limitations of the finite difference time domain technique (FDTD) when used for determining the peak spatial-average and whole-body average specific absorption rate (SAR) in a standardized human anatomical model exposed to the electromagnetic field emitted by vehicle mounted antennas in the frequency range from 30 MHz to 1 GHz, which covers typical high power mobile radio products and… read more applications. This document specifies and provides the test vehicle, human body models and the general benchmark data for those models. It defines antenna locations, operating configurations, exposure conditions, and positions that are typical of persons exposed to the fields generated by vehicle mounted antennas. The extended frequency range up to 6 GHz will be considered in future revisions of this document. This document does not recommend specific peak spatial-average and whole-body average SAR limits since these are found in other documents, e.g. IEEE C95.1-2005, ICNIRP (1998). read less

定价: 159元 / 折扣价: 136

在线阅读 收 藏

This part of IEC/IEEE 62209 specifies measurement protocols and test procedures for the reproducible measurement of peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of a human head or body by radio-frequency (RF) transmitting devices, with a specified measurement uncertainty. Requirements are provided for psSAR assessment using vector measurement-based systems. A vector measurement-based system may have different technical solutions such as scanning system… read more or an array system. Such systems determine the psSAR by three-dimensional (3D) field reconstruction within the volume of interest in accordance with the requirements herein for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for the psSAR assessments covering a significant majority of people including children during use of wireless communication devices operated in close proximity to the head or body. This document is applicable to wireless communication devices intended to be used at a position near the human head or body at distances up to and including 200 mm. This document can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 300 MHz to 6 GHz. The system validation procedures provided within this document cover frequencies from 300 MHz to 6 GHz. The wireless communication device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop and laptop devices, multi-band, multi-antenna, and push-to-talk devices. read less

定价: 173元 / 折扣价: 148

在线阅读 收 藏
264 条记录,每页 15 条,当前第 18 / 18 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页