This specification covers concrete drain tile, to be used for surface and subsurface drainage. Manufactured drain tile shall be of the following classes: standard-quality concrete drain tile, extra-quality concrete drain tile, heavy-duty extra-quality concrete drain tile, and special-quality concrete drain tile. The concrete shall consist of mineral aggregates, water, and cementitious materials that include Portland cement, fly ash, ground granulated blast furnace slag, aggregates, admixtures and blends, and synthetic fibers. Concrete drain tile shall meet the physical requirement of the specification according to class, depending on soil acidity and sulfate content. Test specimens shall meet the external load crushing strength test requirement of the specification.1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.1.2 This specification is the metric counterpart of Specification C412.NOTE 1: This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏
AS 1112.3-2000 ISO metric hexagon nuts Product grade C 现行 发布日期 :  2000-06-23 实施日期 : 

定价: 345元 / 折扣价: 294 加购物车

在线阅读 收 藏
AS 1420-2001 ISO metric hexagon socket head cap screws 现行 发布日期 :  2001-12-07 实施日期 : 

定价: 481元 / 折扣价: 409 加购物车

在线阅读 收 藏

定价: 605元 / 折扣价: 515 加购物车

在线阅读 收 藏

16.1 For purposes of determining compliance with the specified limits for requirements of the properties listed in Table 8, an observed value or calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29.AbstractThis specification covers seamless copper alloy water tubes for general plumbing and similar applications in fluid conveyance. These water tubes made from UNS C10200, C12000, and C12200 copper alloys are commonly used with solder, flared, or compression-type fittings. The materials should be cold-drawn to size and the tubes finished by cold working and annealing to produce the required temper and surface finish. When tubes are furnished in coils, annealing is done after coiling, while those furnished in straight lengths should be in the drawn temper. The numerical values in this specification are not presented in inch-pound units, but rather, in metric or SI units only.1.1 This specification covers seamless copper water tube suitable for general plumbing, similar applications for the conveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper water tube suitable for any particular application is determined by the internal or external fluid pressure, by the installation and service conditions, and by local requirements. Means of joining or bending are also factors that affect the selection of the type of tube to be used.2NOTE 1: Annealed tube is suitable for use with flared or compression fittings, and with solder-type fittings, provided rounding and sizing of the tube ends is performed where needed.NOTE 2: Drawn temper tube is suitable for use with solder-type fittings. Types A and B tube, in the drawn temper, are suitable for use with certain types and sizes of compression fittings.1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:CopperUNS No. Previously UsedDesignation Description     C10200 OF Oxygen free without  residual deoxidantsC12000 DLP Phosphorus deoxidized, low residual phosphorusC12200 DHP Phosphorus deoxidized, high residual phosphorus1.3 The assembly of copper plumbing or fire sprinkler systems by soldering is described in Practice B828.1.4 Solders for joining copper potable water or fire sprinkler systems are covered by Specification B32. The requirements for acceptable fluxes for these systems are covered by Specification B813.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.NOTE 3: This specification is the SI companion to Specification B88.1.6 The following safety hazards caveat pertains only to the test methods portion, Section 15, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

定价: 590 加购物车

在线阅读 收 藏

定价: 646 加购物车

在线阅读 收 藏

11.1 For purposes of determining compliance with the specified limits for requirements of the properties listed in this specification, an observed value or calculated value shall be rounded in accordance with Practice E29.AbstractThis specification covers the requirements for commercial wrought nonferrous nuts in nominal thread diameters M6 to M36 inclusive in a number of alloys in common use and intended for general service applications. Materials shall be tested and shall conform to the chemical composition, hardness, proof stress, proof load, and tensile stress requirements.1.1 This specification covers the requirements for commercial wrought nonferrous nuts in nominal thread diameters M6 to M36 inclusive in a number of alloys in common use and intended for general service applications.1.2 Applicable bolts, cap screws, and studs for use with nuts covered by this specification are covered by Specification F468M.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.NOTE 1: This specification is the metric companion of Specification F467.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 702 加购物车

在线阅读 收 藏

定价: 590 加购物车

在线阅读 收 藏

This specification covers the materials, dimensions, and assembly of steel and aluminum rat guards intended to prevent rats from boarding ships by way of mooring lines. Rat guards shall be classified into three types, namely: Type I, Type II, and Type III. Type I rat guards shall be made of the prescribed aluminum-alloy sheet metal; Type II rat guards shall be made of the prescribed galvanized sheet steel; and Type III rat guards shall be made of either of these specified materials. Types I and II rat guards shall be provided with the following: hinge bolt, guide and tie rope, and grommet. Type III rat guards shall consist of two half disks and two half tapered sleeves and the hinge bolt provided with each rat guard shall consist of a commercial hexagon head bolt, nut, and washer, all made of corrosion resistant steel. The dimensional requirements such as thickness of disk, sleeve, and guide for galvanized steel or aluminum sleeve of Type III rat guard are specified. Type I and Type II rat guard configurations and Type III rat guard assembly are detailed and illustrated.1.1 This specification covers the materials, dimensions, and assembly of steel and aluminum rat guards.1.2 Rat guards are intended to prevent rats from boarding ships by way of mooring lines.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏
AS 1684-1975 SAA light timber framing code Metric Units 现行 发布日期 :  实施日期 : 

定价: 1177元 / 折扣价: 1001 加购物车

在线阅读 收 藏

定价: 777 加购物车

在线阅读 收 藏

This guide covers standard specification for stainless steel, textured sheets, especially for use in electronic packaging applications. The textured side or sides of the sheet shall be produced in such a manner that guarantees repeatability of the pattern over time. The texture of any sheet shall conform to the textured reference identification criteria: pattern orientation; pattern appearance; height of pattern; size of pattern; type of pattern; pattern repetition configuration; and pattern effect on far side of sheet. The heat chemical composition shall be reported and shall conform to the specified requirements. The material shall undergo all the tests and inspections such as appearance testing, tensile strength testing, and corrosion testing in indoor and outdoor environment.1.1 This specification covers stainless steel, textured sheets, especially for use in electronic packaging applications, for example, cabinet, rack, enclosure, and shelf constructions for telecommunication, computer, and data-processing equipment.1.2 This specification applies to all finished flat-rolled stainless products specified by standards organizations such as International Standards Organization (ISO), American Society for Testing and Materials (ASTM), European Committee for Standardization (CEN), German Institute for Standardization (DIN), and others participating in a global standards harmonization effort.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

定价: 590 加购物车

在线阅读 收 藏

This specification prescribes the recommended standard metric sizes of solid round electrical conductors. The standard diameters of metric sizes of wires are preferred numbers calculated in accordance with the conventional mathematical principles. The standard metric size of stranded conductors and equivalent cross-sectional areas shall be designated.1.1 This specification covers and prescribes the recommended standard metric sizes of solid round electrical conductors.1.2 This specification prescribes the recommended standard metric size designations of stranded electrical conductors (see Explanatory Note 1).NOTE 1: Physical properties, construction requirements, and manufacturing tolerances for specific products should be included in individual product specifications developed in accordance with appropriate sizes in this specification.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3.1 Exceptions — For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. Rounded values appear in Table 1.(A) The inch diameters, square inch areas, and circular mil areas are rounded values calculated from the metric diameters.

定价: 515 加购物车

在线阅读 收 藏