微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

4.1 The presence of 4-CBA and p-TOL in PTA used for the production of polyester is undesirable because they can slow down the polymerization process and 4-CBA imparts coloration to the polymer due to thermal instability.4.2 Determining the amount of 4-CBA and p-TOL remaining from the manufacture of PTA is often required. This test method is suitable for setting specifications and for use as an internal quality control tool where these products are produced or are used.1.1 This test method covers the determination of the 4-Carboxybenzaldehyde (4-CBA) and p-Toluic acid (p-TOL) in purified terephthalic acid (PTA) by reverse phase high performance liquid chromatography (HPLC). This method is applicable for 4-CBA from 2 to 500 mg/kg and for p-TOL from 10 to 500 mg/kg, respectively.1.2 In determining the conformance of the test results using this method to applicable specification, results shall be rounded off in accordance with the rounding-off method of Practice E29.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

定价: 541元 / 折扣价: 482 加购物车

在线阅读 收 藏
DIN ISO 7801 Metallic Materials - Wire - Reverse bend test (ISO 7801:1984) 现行 发布日期 :  2001-10-01 实施日期 : 

定价: 394

在线阅读 收 藏

定价: 394

在线阅读 收 藏

5.1 In the design and operation of reverse osmosis installations, it is important to predict the SiO2 scaling properties of the concentrate stream. Because of the increase in the concentration of SiO2 and the change in pH, the scaling property of the concentrate stream will be quite different from that of the feed solution. This practice permits the calculation of the scaling potential for the concentrate stream from the feedwater analysis and the reverse osmosis operating parameters.5.2 Scaling by SiO2 will adversely affect the reverse osmosis performance. This practice gives various procedures for the prevention of scaling.5.3 The presence of certain metals, for example, Al+3, may significantly alter the solubility of SiO2 via formation of insoluble metal silicates. This practice does not address this phenomena.1.1 This practice covers the calculation and adjustment of silica (SiO2) for the concentrate stream of a reverse osmosis system. The calculations are used to determine the need for scale control in the operation and design of reverse osmosis installations. This practice is applicable for all types of reverse osmosis devices (tubular, spiral wound, and hollow fiber).1.2 This practice is applicable to both brackish waters and seawaters.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0

在线阅读 收 藏
DIN 51211 Testing of Metallic Materials; Reverse Bend Test of Wires 废止 发布日期 :  2001-09-01 实施日期 : 

定价: 191

在线阅读 收 藏
DIN 1474 Grooved Pins, Half Length Reverse-grooved 废止 发布日期 :  2001-11-01 实施日期 : 

定价: 191

52 条记录,每页 15 条,当前第 3 / 4 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页