This standard includes procedures for evaluating the compliance of wireless power transfer (WPT) equipment with applicable electromagnetic compatibility (EMC) requirements. Test procedures for radiated field strength and conducted disturbance measurements are included, with reference to established standards, where applicable. WPT RF exposure compliance procedures are not included. This document covers measurement methodologies but is not intended to specify regulatory limits. This standard… read more does not consider test methods for the transmitter or receiver portion of any radio apparatus subcomponents that might be included in the equipment under test (EUT), other than those operating at the WPT frequency (or frequencies). These non-WPT radio subcomponents, which can be related or not to the WPT function of the EUT, are covered by other standards (e.g., ANSI C63.10 [B1] and ANSI C63.26 [B2]). read less

定价: 183元 / 折扣价: 156

在线阅读 收 藏

This standard establishes minimum acceptance performance requirements for portable radiation protection instruments used for detection and measurement of ionizing radiation fields or levels of radioactive surface contamination that are near background. For purposes of this standard, portable radiation protection instruments are those battery-powered instruments that are carried to a specific facility or location for use. Specifically, this standard is intended to apply to those instruments… read more utilized to make in-situ measurements for confirmation of residual radioactivity levels that are below criteria established to permit the unrestricted release of a surface area or component from further regulatory controls. This standard is intended to define performance requirements and acceptance testing that supplements those established in ANSI N42.17A-1989 [B7] and ANSI N42.17C-1989 [B8], and to define calibration requirements that supplement those established in ANSI N323A-1998 [B6].1 This standard is applicable to the measurement of gamma, beta, and alpha radiation emissions only. This standard addresses the instrument response requirements for the same range of surface activity covered by the above ANSI standards, but extends the applicable range of dose-rate response below those standards. This is illustrated in Table 1. Throughout this standard, three verbs have been used to indicate the degree of rigor intended for each specific test or performance criterion. The word "shall" is used to denote a requirement; the word "should" to denote a recommendation; and the word "may" to denote a permissible practice. read less

定价: 87元 / 折扣价: 74

在线阅读 收 藏

The scope of this standard is to establish minimum performance criteria and test requirements for four categories of alarming electronic radiation measurement instruments used to manage exposure by alerting the emergency responders when they are exposed to photon radiation. The instruments provide rapid and clear indication of the level of radiation exposure and/or exposure rate and readily recognizable alarms. The alarms are both audible and visual, and distinguishable between exposure rate… read more and exposure. Vibratory alarms are optional. Emergency responders include fire and rescue services, law enforcement, and medical services. Other possible users include Critical Infrastructure Key Resources (CIKR) such as heavy equipment, transportation, and utilities personnel. read less

定价: 99元 / 折扣价: 85

在线阅读 收 藏

This standard provides the schedules of preferred ratings and construction specifications for high-voltage disconnect, interrupter, fault initiating, and grounding switches rated above 1000 volts. Switch operator control voltage ranges (formerly C37.33), bus supports and accessories are also covered by this standard. Switches included in C37.20.2, C37.20.3, C37.20.4, C37.71, C37.72 and C37.73 are not covered by this standard.

定价: 74元 / 折扣价: 63

在线阅读 收 藏

This standard establishes specifications for high voltage (above 1000 volts) distribution class current limiting type fuses and associated accessories. All of these devices are intended for use on alternating current systems. These specifications apply to the following specific types of equipment: a) Distribution class current limiting type fuses and fuse units. b) Distribution class current-limiting fuse disconnecting switches. c) Items (a) thru (b) used in fuse enclosure packages (FEP) (see… read more types listed in Clause 1.1 below) d) Fuse supports, fuse units, refill units and fuse mountings of the type used exclusively with distribution class current limiting type fuses, and fuse disconnecting switches. e) Removable switch blades of the type used exclusively with distribution class current limiting type fuses, and fuse disconnecting switches. read less

定价: 74元 / 折扣价: 63

在线阅读 收 藏

This standard establishes minimum acceptable performance criteria for health physics instrumentation for use in ionizing radiation fields under extreme environmental conditions. Included are testing methods to establish the acceptability of each type of instrumentation. This standard does not specify which instruments or systems are required, nor does it consider the number of specific applications of such instruments. This standard supplements the basic performance requirements for health physics instrumentation as specified in ANSI N42.17A [2]. Specifications in this standard are expected to be called for by the user as required and should not be considered as general specifications.

定价: 150元 / 折扣价: 128

在线阅读 收 藏

This standard specifies the basic performance requirements for backpack-based radiation-detection systems (BRDs) used in homeland security applications. BRDs consist of a body worn detection assembly that may be carried in a backpack, vest, or shoulder bag, and a wired or wireless user interface/display. BRDs shall detect gamma radiation and may include neutron detection and/or the identification of gamma-ray emitting radionuclides.

定价: 84元 / 折扣价: 72

在线阅读 收 藏

You get the complete 2007 NESC in a new point-and-click HTML format as well as the official 2007 NESC in the Classic Adobe PDF format. With internet access, you get exclusive hyperlinks to essential resources including the IEEE Electrical Safety Resource Center, the NESC¿¿ Zone, and so much more. New search, linking, and navigational features are available to assist you! No more thumbing through hundreds of pages for cross-referenced material. Just click! Rules are linked together enabling you… read more to move forward and back as you like. Jump to any table in feet or meters with ease. View color-coded changes from the 2002 NESC, copy and paste an important passage, print pages on your inkjet or laser printer. Not satisfied with the size or color of the text Change it. VuSpec is customizable. Starts immediately, no installation or login required. Also includes the NESC Glossary, just key in a term and see its definition. read less

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This standard establishes the minimum performance criteria for health physics instrumentation for use in ionizing radiation fields. Testing methods are included to establish the acceptability of each type of instrumentation. This standard does not specify which instruments or systems are required, nor does it consider the number of specific applications of such instruments.

定价: 81元 / 折扣价: 69

在线阅读 收 藏

The scope of this standard is to establish minimum performance criteria and test requirements for nonalarming radiation detectors used to manage the exposure of emergency responders to photon radiation. The detectors shall provide rapid and clear indication of the level of radiation exposure. Emergency responders include fire services, law enforcement, and medical services. Other possible users include critical infrastructure key resources (CIKR) such as heavy equipment, transportation, and… read more utilities personnel and members of the public who may be involved in emergency situations. read less

定价: 81元 / 折扣价: 69