This specification covers polyetheretherketone (PEEK) polymer in virgin forms as pellets, powder, and so forth. It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices such as surgical implants or components of surgical or dental devices. The PEEK polymer in the scope of this specification is a pure semicrystalline homopolymer consisting of phenylene rings connected by ether (E) and carbonyl (or ketone, K) groups along the polymer chain. Its polymeric structure is defined by the repeating unit EEK. As with any material, some characteristics may be altered by the processing techniques (molding, extrusion, machining, assembly, sterilization, and so forth) required for the production of a specific part or device. Therefore, properties of fabricated forms of these polymers shall be evaluated using appropriate test methods such as US Pharmacopeia test (infrared spectroscopy, viscosity measurements, and total heavy metal content (as lead)), and differential scanning calorimetry. Fabricated forms, material or forms containing colorants, fillers, processing aids, or other additives, as well as polymer blends which contain PEEK, or reclaimed materials, are not covered by this specification. The properties which shall be evaluated are the following: density, tensile strength, elongation, flexural strength, flexural modulus, and impact strength. The biocompatibility of PEEK polymers is also detailed.1.1 This specification covers polyetheretherketone (PEEK) polymer in virgin forms (for example, pellets, granules, powder, filaments used in additive manufacturing) and fabricated forms. It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices such as surgical implants or components of surgical or dental devices.1.2 The properties included in this specification are those applicable for PEEK polymers only. Indicated properties are for fabricated forms. Materials or forms containing colorants, fillers, processing aids, or other additives, as well as polymer blends which contain PEEK, or reclaimed materials, are not covered by this specification.1.3 This specification is designed to recommend physical, chemical, and biological test methods to establish a reasonable level of confidence concerning the performance of virgin PEEK polymers for use in medical implant devices.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 When evaluating material in accordance with this specification, hazardous materials, operations, and equipment may be involved. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

4.1 This specification provides minimum requirements for surgical gowns used for protection of healthcare workers where the potential for exposure to blood, body fluids, and other potentially infectious materials exists. The specification requires barrier testing based on the system of classifying gowns established in ANSI/AAMI PB70 and sets general safety requirements for surgical gowns based on biocompatibility, sterility assurance, and flame spread. Performance requirements are established for important physical properties, including tensile strength, tear strength, and seam strength. Methods to be used for optional reporting of performance of linting resistance, evaporative resistance, water vapor transmission rate, and abrasion resistance are provided.4.2 This specification does not address protective clothing used for nonsurgical applications, such as isolation gowns or decontamination gowns; protective clothing for the hands, such as surgical gloves, patient examination gloves, or other medical gloves; protective clothing for the head, such as goggles or face shields, surgical caps or hoods, surgical masks, or respirators; protective clothing for the feet, such as operating room shoes, shoe covers, or surgical boots; or other types of protective clothing and equipment worn by healthcare providers.4.3 Surgical gowns are either multiple-use or single-use products as designated by the manufacturer. This specification is intended to provide the basis for manufacturer claims for surgical gown performance and efficacy. For multiple-use gowns, this specification takes into account the anticipated care and maintenance of these products by examining test requirements for surgical gown materials both before and after the maximum expected number of cycles for laundering and sterilization.4.4 Additional information on the processing of multiple-use surgical gowns is provided in ANSI/AAMI ST65.4.5 While surgical gowns are classified for barrier performance as specified in ANSI/AAMI PB70, this specification establishes other design criteria, minimum physical performance criteria, labeling, and documentation requirements for surgical gowns and their materials.4.5.1 In addition to the barrier performance of the surgical gown material and seams, surgical gown material and seams are also required to meet minimum requirements for tensile strength, tear strength, and seam strength that have been established on the basis of an analysis of workplace requirements. Surgical gowns with different barrier level claims shall meet the same minimum strength requirements regardless of their barrier level.4.5.2 Additional properties for surgical gown material such as lint generation, evaporative resistance or water vapor transmission rate, and durability are optional for testing for the purpose of documenting performance. No minimum criteria are established for these properties, but purchasers may use this information to compare products.4.5.3 Surgical gowns differ from isolation gowns based on their intended use and anticipated location of liquid contact. Specific requirements for isolation gowns beyond the barrier performance of isolation gown materials and seams are provided in Specification F3352/F3352M.4.6 Additional information for the testing, selection, and use of surgical gowns is provided in AAMI TIR11.AbstractThis specification establishes the requirements for the performance, documentation, and labeling of surgical gowns used in the healthcare facilities. It does not however cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products. Barrier testing shall be conducted to determine the impact penetration, hydrostatic resistance, and viral penetration resistance performance of the critical zone(s) of the surgical gown. The physical properties of the critical zone(s) of the surgical gown shall also be tested and shall conform to the following requirements: tensile strength, tear resistance, seam strength, lint generation, evaporative resistance, and water vapor transmission rate. General safety requirements shall be set based on biocompatibility, sterility assurance, flame spread, and natural rubber latex specifications.1.1 This specification establishes requirements for the performance, documentation, and labeling of surgical gowns used in healthcare facilities. Four levels of barrier properties for surgical gowns are specified in ANSI/AAMI PB70 and are included in this specification for reference purposes.NOTE 1: Some properties require minimum performance and others are for documentation only.NOTE 2: ANSI/AAMI PB70 evaluates the barrier properties of surgical gown fabrics using water only in Levels 1, 2, and 3. Since surgical gowns are exposed to blood and other fluids with different surface tensions, the performance of additional testing to identify the barrier levels to simulated biological fluids is required for a Level 4 gown.1.2 This specification does not cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products.1.3 This specification is not intended to serve as a detailed manufacturing or purchase specification, but can be referenced in purchase specifications as the basis for selecting test requirements.1.4 The values stated in SI units or in other units shall be regarded separately as standard. The values stated in each system must be used independently of the other, without combining values in any way.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646 加购物车

在线阅读 收 藏

This specification covers virgin polyetherketoneketone (PEKK) polymer resin as supplied by a vendor (for example, in pellets, powder, and fabricated forms). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices such as surgical implants or components of surgical or dental devices. As with any material, some characteristics may be altered by the processing techniques (for example, molding, extrusion, machining, assembly, and sterilization) required for the production of a specific part or device. Therefore, properties of fabricated forms of these polymers should be evaluated using test methods which are appropriate to ensure safety and efficacy as agreed upon by the vendor, purchaser, and regulating bodies. This specification is designed to recommend physical, chemical, and biological test methods to establish a reasonable level of confidence concerning the performance of virgin PEKK polymers for use in medical implant devices. It lists the properties that should be considered in selecting material(s) in accordance with the specific end-use requirements. This specification also addresses classification, properties, sampling, and biocompatibility.1.1 This specification covers virgin polyetherketoneketone (PEKK) polymer resin as supplied by a vendor (for example, in pellets, powder, and fabricated forms). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices such as surgical implants or components of surgical or dental devices.1.2 As with any material, some characteristics may be altered by the processing techniques (for example, molding, extrusion, machining, assembly, and sterilization) required for the production of a specific part or device. Therefore, properties of fabricated forms of these polymers should be evaluated using test methods which are appropriate to ensure safety and efficacy as agreed upon by the vendor, purchaser, and regulating bodies. With reduced crystallinity, certain polymers have been shown to be more susceptible to environmental stress cracking. Depending upon the implant application, the end user should characterize the material for environmental stress cracking resistance.1.3 The properties included in this specification are those applicable for PEKK polymers only. Indicated properties are for fabricated forms. Fabricated forms and materials containing colorants, fillers, processing aids, or other additives, as well as polymer blends which contain PEKK, or reclaimed materials are not covered by this specification.1.4 This specification is designed to recommend physical, chemical, and biological test methods to establish a reasonable level of confidence concerning the performance of virgin PEKK polymers for use in medical implant devices. The properties listed should be considered in selecting material(s) in accordance with the specific end-use requirements.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 When evaluating material in accordance with this specification, hazardous materials, operations, and equipment may be involved. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

This specification covers the raw material and final product requirements, and the associated test methods for the selection of porous high density and ultra high molecular weight polyethylenes intended for use in surgical implants. The porous polyethylene may be used as a free standing product or as a coating on a substrate in nonloaded applications. Physical properties such as pore size and volume, as well as tensile, compressive, flexural, and shear properties shall be determined, but will be specified in the particular device to which its end use shall be applied.1.1 This specification covers the properties and test methods for porous high-density-polyethylene (HDPE) and porous ultra-high-molecular-weight-polyethylene (UHMWPE) intended for use in surgical implants. The porous polyethylene may be used as a free-standing product or as a coating on a substrate in non-loaded applications.1.2 Materials covered by this standard can have a broad range of mechanical and morphological properties depending on the starting material and fabrication processes. Therefore no attempt has been made to standardize the properties, and the requirements for a specific application are not within the scope of this standard.1.3 Evaluation of the tissue response to a porous polyethylene must be completed. Guidance in establishing biocompatibility may be found in the list of references.1.4 Clinical experience and animal studies have shown that tissue will grow into the open pores of porous polyethylene. The tissue ingrowth into the pores may facilitate the establishment of implant fixation.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515 加购物车

在线阅读 收 藏

5.1 The procedure in this test method should be used to evaluate the activity of the test formulation in reducing the bacterial population of the hands immediately after a single use and to determine persistent activity (inhibition of growth) after 6 h. Optionally, measurements of persistent activity after a 3 h period and measurements of cumulative activity may be made after repetitive uses over a five day period.1.1 This test method is designed to measure the reduction of microbial flora on the skin. It is intended for determining both immediate and persistent (continuing antimicrobial effect) microbial reductions, after single or repetitive treatments, or both. It may also be used to measure cumulative antimicrobial activity after repetitive treatments.1.2 A knowledge of microbiological techniques is required for these procedures.1.3 Performance of this procedure requires the knowledge of regulations pertaining to the protection of human subjects (21 CFR, Parts 50 and 56)1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4.1 In this test method, SI units are used for all applications, except for distance, in which case inches are used and SI units follow in parentheses.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

This specification covers chemical and crystallographic requirements for hydroxylapatite intended for surgical implants. Elemental analysis for calcium and phosphorus will be consistent with the expected stoichiometry of hydroxylapatite. The calcium and phosphorus contents shall be determined using a suitable method such as ion chromatography. A quantitative X-ray diffraction analysis shall indicate a minimum hydroxylapatite content of 95 %. The concentration of trace elements such as arsenic, cadmium, mercury, and lead shall be determined for hydroxylapatite derived from natural resources. The analysis of other trace elements may be required, based on the conditions, apparatus, or environments specific to the manufacturing techniques and raw materials. Either inductively coupled plasma/mass spectroscopy (ICP/MS), atomic absorption (AAS), or the methods mentioned shall be used.1.1 This specification covers chemical and crystallographic requirements for hydroxylapatite intended for surgical implants. For a material to be called medical-grade hydroxylapatite, it must conform to this specification. (See Appendix X1.)1.2 The biological response to hydroxylapatite in soft tissue and bone has been characterized by a history of clinical use (1-3)2 and by laboratory studies (4-6).1.3 This specification includes powder, particulate, and forms intended for use as surgical implants, components of surgical implants, or as raw materials for manufacturing processes such as thermal spray coating, electrophoretic deposition, physical vapor deposition, and so forth.1.4 This specification specifically excludes hydroxylapatite coatings, amorphous calcium phosphate, ceramic-glasses, tribasic calcium phosphate, whitlockite, and alpha- and beta-tricalcium phosphate (see Specification F1088).1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515 加购物车

在线阅读 收 藏

1.1 This terminology defines basic terms and considerations for the components of scissors with either inserted or non-inserted blades (see Fig. 1). Instruments in this terminology are limited to those fabricated having scissor blades made from stainless steel and used for surgical procedures.FIG. 1 Components of a Scissors (Inserted and Non-Inserted)1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515 加购物车

在线阅读 收 藏

This specification covers the requirements for three compositions of wrought seamless stainless steel tubing for the manufacture of surgical implants. Materials shall be tested and shall conform to chemical composition, metallurgical requirements, and mechanical properties. Materials and manufacture are also detailed.1.1 This specification covers the requirements for five compositions of wrought seamless stainless steel tubing for the manufacture of surgical implants. Material shall conform to the applicable requirements of Specification F138, F1314, F1586, F2229, or F2581. This specification addresses those product variables that differentiate wrought seamless tubing from the bar and wire product forms covered in these specifications.1.2 This specification applies to cold finished, straight length tubing from 3 to 34 mm [0.125 to 1.315 in.] nominal outside diameter (OD) and 0.5 mm [0.020 in.] and greater nominal wall thickness.1.3 The specifications in 2.1 are referred to as the ASTM material standard(s) in this specification.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other and values from the two systems shall not be combined.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏