微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

3.1 Poor adhesion of ink or coating to the base substrate can impact the readability of printed materials, affect the functionality of coated materials, or create a source of contamination. This practice provides a means for evaluating the adhesion of ink or coating to a flexible packaging material.3.2 For purposes of resolving inter-laboratory disagreements, test methods developed from this practice may be improved by defining and controlling the pressure and method of tape application, (for example, using weighted roller), and the speed and angle of tape removal.3.3 This practice does not address acceptability criteria. These need to be jointly determined by the user and producer of the product.1.1 This practice describes a means of evaluating ink or coating adhesion to flexible packaging materials. This practice is intended for use on flexible packaging materials whose surfaces are not damaged by the application and removal of tape.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers white or yellow preformed retroreflective pavement marking tape, that when applied to a road surface, will provide a service life normally greater than one year depending on the average daily traffic count (ADT). The preformed retroreflective pavement tape is suitable for longitudinal markings and transverse markings including word/symbol markings. It is designed to be a pavement marking with extended service life. Preformed retroreflective pavement marking tape shall be identified as: reflectivity Level I; Class 1, 2 or 3; skid resistance Level A, or B and reflectivity Level II; Class 1, 2 or 3; skid resistance Level A, or B. Color, dimensions, retroreflection, adhesion, skid resistance, durability, and wear resistance tests shall be performed to conform to the specified requirements.1.1 This specification covers white or yellow preformed retroreflective pavement marking tape that, when applied to a road surface, will provide a service life normally greater than one year depending on wear and durability factors.1.2 The preformed retroreflective pavement tape is suitable for longitudinal markings and transverse markings including word/symbol markings. It is designed to be a pavement marking with extended service life.1.3 The values stated in inch-pound units are to be regarded as the standard except where noted in the document. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers zinc-coated flat steel tape in coils for use as interlocking armor and flat armor for electric cables. The zinc-coated tape is produced with three classes of zinc coating weight. The zinc-coated tape shall be furnished in coils of one continuous length, with not more than an average of one weld/50 lb [23 kg]. The tensile strength shall be determined on longitudinal specimens consisting of the full width of the tape when practical, or a straight specimen cut or sheared from the center of the tape. The elongation shall be determined as the permanent increase in length, after failure of a marked section of the tape specimen originally 10 in. in length. The tape shall be capable of being bent flat on itself, either lengthwise or crosswise, without indication of failure. During the visual inspection, 1 sample coil shall random be selected from every 10 coils in the first 100 coils of the lot and 1 sample coil shall random be selected for every additional 35 coils, but not less than 3 coils from the entire lot. The weight of coating shall be determined by the hydrochloric acid-antimony chloride method. The zinc coating shall remain adherent without flaking or spalling when the tape is subjected to a 180° bend over a mandrel of required diameter.1.1 This specification covers requirements for zinc-coated flat steel tape in coils for use as interlocking armor and flat armor for electrical cables. The zinc-coated tape is produced with three classes of zinc coating weight.1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
ASTM D4514-12 Standard Specification for Friction Tape (Withdrawn 2020) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

This specification covers friction tapes that are commonly used for protecting, and binding in place, insulation applied to joints of electrical wires and cables, and for other mechanical purposes. The tape shall consist of a woven fabric sheeting impregnated with a frictioning compound (an adhesive insulating compound), cut into rolls of narrow width and wound on a core. Friction tapes shall meet the prescribed requirements such as adhesion, aged adhesion, breaking strength, breakdown voltage, parallelism, and tackiness. The specified dimensional requirements includes nominal width, thickness, and length. The aging and storage requirements as well as the test methods to determine conformance to the prescribed requirements are given.1.1 This specification covers friction tapes that are commonly used for protecting, and binding in place, insulation applied to joints of electrical wires and cables, and for other mechanical purposes.1.2 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are for information only.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
AS 1069-1971 Dimensions for punched paper tape for data interchange 被代替 发布日期 :  1970-01-01 实施日期 : 

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

5.1 When a box becomes wet, the performance of the box and its closure are reduced. It is desirable to have box closure methods that retain an ability to keep the box closed when wet. Sealing or reinforcing methods sometimes are useful to improve performance of wet boxes and closures. Water resistance is sometimes a regulatory or contractual requirement.5.2 A test result indicating that a box closure tape or adhesive is soluble or dispersible in water is an indication that its function will be significantly impaired when wet. A test result that does not indicate solubility or dispersibility does not necessarily ensure that the bonding ability will be satisfactory when wet or that the performance of the box closure will be satisfactory when wet. Package performance testing described in the water resistance section of Practice D1974 is useful to further investigate the effects of water on package and closure functions.1.1 This test method covers a procedure to determine the water resistance of an adhesive or tape as measured by the amount of tape or adhesive dissolved or dispersed in water.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

定价: 85元 / 折扣价: 73

在线阅读 收 藏

This specification establishes the manufacture of and requirements for two types and two grades of electrical insulating tape consisting of a polytetrafluoroethylene (PTFE) film coated on one side with a pressure-sensitive adhesive. Type I is standard backing, while Type II is bondable backing tape. Grades are designate based on backing thickness. Besides standard lengths, widths, and thicknesses, tapes shall also conform to other requirements such as breaking strength, elongation, adhesion to steel and backing, dielectric breakdown, and high-humidity insulation resistance.1.1 This specification covers electrical insulating tape consisting of a polytetrafluoroethylene (PTFE) film coated on one side with a pressure-sensitive adhesive.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.NOTE 1: This standard is similar to IEC 60454-3-14.1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Tape sealants are tacky, deformable solids, which are used under compression between two or more surfaces of similar or dissimilar substrates in a variety of sealing applications. These tapes are normally supplied in a roll form with a release paper interlever and are hand pressed against a fixed substrate. This procedure is designed to give an indication of the flow characteristics of a tape sealant under controlled temperature and aging conditions with a specified load.1.1 This test method describes a laboratory procedure for determining the flow characteristics of preformed tape sealants after a specified time, temperature, and load.1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are provided for information purposes only.1.3 The committee with jurisdiction of this specification is not aware of any similar specification within ISO or any other organization.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 Diametral compression strength is an important measure of the mechanical properties of casting materials. This test method simulates the loading pattern seen in lower extremity casting applications during ambulation. This test method cannot be used to determine cast life or measure bending or other modes of cast failure.5.2 This test method measures but does not prescribe values.1.1 This test method covers the functional diametral compression strength of cylindrical test specimens formed from synthetic fiberglass polyurethane casting materials. The test specimens employed in this test method are similar in geometry and construction to casts used in orthopaedic applications. This test method is not intended to determine the strength of the base materials used for fabrication of the test specimen.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 6.7.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
ASTM E3233-20 Standard Practice for Forensic Tape Analysis Training Program Active 发布日期 :  1970-01-01 实施日期 : 

3.1 The procedures outlined herein are grounded in the generally accepted body of knowledge and experience in the field of forensic tape examination and comparison.3.2 With successful completion of this tape analysis training program, the trainee gains the theoretical knowledge and practical skills necessary to perform, document, and evaluate forensic tape examinations and comparisons.3.3 This training practice covers a variety of instrumental methods which can be used in the analysis of tape. Not all laboratories will have access to all of the instrumentation. It is expected that a tape analysis training program will include all the techniques that are found within a laboratory’s procedures for the forensic examination of tape.3.3.1 Instrumental methods that provide organic and inorganic analysis capabilities are utilized in the laboratory training program. Examples include Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, pyrolysis gas chromatography (PGC), scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM/EDS), X-ray fluorescence (XRF), or X-ray diffraction (XRD).1.1 This standard is intended as a practice for use by laboratory personnel responsible for training examiners to perform forensic examinations and comparisons on pressure sensitive tapes and adhesives. It contains a list of training objectives with recommended methods of instruction, reading assignments and structured exercises to provide practical experience for the trainee.1.1.1 The trainees and training program shall meet or exceed the minimum training requirements set forth in Practice E2917.1.1.2 Additional training could be required for a particular method or instrument referred to herein. The application of analytical techniques to tape analysis assumes the trainee is already competent in the use of each particular analytical technique or instrumental method.1.1.3 Other sources of information on forensic tape examination not specifically mentioned in this document can be considered and added.1.1.4 Additional tape analysis training beyond that which is listed here should be made available to the trainee. Such training could include off-site courses, internships, and specialized training by experienced examiners.1.1.5 Continuing education and training is recommended. Additional training provides a forensic tape examiner with the opportunity to remain current in the field.1.1.6 Tape samples are evaluated for physical matches of the cut or torn end pieces. This practice does not provide training requirements for physical match comparisons. Additional training is required to conduct this type of analysis.1.2 This practice is in a modular format for easy adaptation to an individual laboratory’s training program. Recommendations as to lessons, practical exercises, progress monitoring, and trainee evaluations are included. Reading assignments are listed in each subsequent section of this practice; full citations are available in the References section.1.3 A tape analysis training program provides a theoretical foundation and basic practical skills necessary to prepare a trainee to become a qualified forensic tape examiner. At the end of the tape analysis training program, the trainee is capable of forming opinions based upon sound scientific knowledge, appropriate examinations, and practical experience. The trainee also is able to independently work cases, write reports, testify in court, and peer review cases. Upon completion of the program by a trainee or at some regular interval (for example, once per accreditation cycle), the training program should be evaluated for its efficacy and relevance according to the guidance set forth in Practice E2917.1.4 This practice does not address human factors (for example, cognitive bias). It is the responsibility of the user of this practice to address human factors during the initial or general training of a forensic scientist.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers one type of pressure-sensitive tape for closing and sealing slip cover type containers such as fiber tubes and metal cans. The polyester film backed pressure-sensitive tape is intended for closure and sealing of containers with slip cover closure, such as fiber spirally wound tubes and metal cans where strength, water-resistance, water-vapor resistance and resistance to rain and other deteriorating elements are required. The tape shall comply with the physical property requirements specified. The following test methods shall be performed to conform to the specified requirements: adhesion; shear adhesion; tensile; thickness; unwind; water penetration rate; water vapor transmission rate; and accelerated aging.1.1 This specification covers one type of pressure-sensitive tape for closing and sealing slip cover type containers such as fiber tubes and metal cans.1.2 The values stated in either inch-pound or SI units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently, without combining values in any way.1.3 The following safety hazards caveat pertains only to the test methods portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
ASTM C972-24 Standard Test Method for Compression-Recovery of Tape Sealant Active 发布日期 :  1970-01-01 实施日期 : 

4.1 Tape sealants are tacky, deformable solids used between two or more surfaces of similar or dissimilar materials in a variety of sealing applications. This procedure presents an indication of the compression recovery characteristics of preformed tapes.1.1 This test method covers a laboratory procedure for determining compression-recovery characteristics of tape sealant.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.NOTE 1: There are no ISO standards similar or equivalent to this ASTM standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
AS 1195-1973 Polytetrafluoroethylene (PTFE) skived tape 被代替 发布日期 :  1970-01-01 实施日期 : 

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏
83 条记录,每页 15 条,当前第 4 / 6 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页