微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

Information technology - Open Systems Interconnection - Connection-oriented presentation protocol: Protocol specification AMENDMENT 2: Nested connections functional unit

定价: 182元 / 折扣价: 155

在线阅读 收 藏

AbstractThese test methods cover the measurement of fabric mass per unit area (weight) and is applicable to most fabrics. There are four approved options in the measurement of fabric mass per unit area: Option A, Option B, Option C, and Option D. Option A may be used for acceptance testing of commercial shipments since it has been used extensively in the trade. The second option is Option B which is applicable to a full-width sample cut from a full piece, roll, bolt, or cut. Unless otherwise specified, these results will include selvages and will be on the basis of conditioned fabric. Option C on the other hand is applicable when a small swatch of fabric is sent to the laboratory to be used as the test specimen. The results are considered to be applicable to the sample only and not necessarily to the lot from which the sample was taken. Measurements by this method do not include selvages and should be reported as such, unless a selvage allowance is specified. The last option is Option D which is intended for use with narrow fabrics as so designated by the trade.1.1 These test methods cover the measurement of fabric mass per unit area (traditionally referred to as “fabric weight”) and are applicable to most fabrics.1.2 There are four approved options:1.2.1 Option A—Full Piece, Roll, Bolt or Cut (Section 7).1.2.2 Option B—Full Width Sample (Section 8).1.2.3 Option C—Small Swatch of Fabric (Section 9).1.2.4 Option D—Narrow Fabrics (Section 10).1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM E2188-19 Standard Test Method for Insulating Glass Unit Performance Active 发布日期 :  1970-01-01 实施日期 : 

4.1 This test method is intended to provide a means for testing the performance of the sealing system and construction of insulating glass units.4.1.1 Insulating glass units tested in accordance with this method may be suitable for structurally glazed applications. However, factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications.4.1.2 Insulating glass units tested in accordance with this method are not intended for continuous exposure to high relative humidity conditions or long-term immersion in water.1.1 This test method covers procedures for testing the performance of preassembled permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open.1.2 This test method is applicable only to insulating glass units that are constructed with glass.1.3 This test method is applicable to both double-glazed and triple-glazed insulating glass units. For triple-glazed insulating glass units where both of the outer lites are glass and the inner lite is either glass or a suspended film.1.4 The unit construction used in this test method contains dimensions that are an essential component of the test. Different types of glass, different glass thicknesses, and different cavity sizes may affect the test results.1.5 This test method is not applicable to insulating glass units containing a spandrel glass coating due to testing limitations.1.6 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This specification covers preassembled permanently sealed insulating glass units with one or two cavities and preassembled insulating glass (IG) units with capillary tubes intentionally left open or closed.1.2 This specification is applicable only to insulating glass units that are constructed with glass or suspended film.1.3 This specification is applicable to both double-glazed and triple-glazed insulating glass units; for triple-glazed insulating glass units where both of the outer lites are glass and middle lite is either glass or a suspended film.1.4 The qualification of test specimens is based on frost/dew point and on the absence of fog after the specified test durations.1.5 The qualification of argon gas-filled test specimens is based on maintaining the specified argon gas amounts before and after testing to Test Method E2188.1.6 Qualification under this specification is intended to provide a basis for evaluating the durability of insulating glass units.1.7 This specification is not applicable to insulating glass units containing a spandrel glass coating due to test method limitations.1.8 This specification does not cover other physical requirements such as appearance, thermophysical properties, heat and light transmission, and glass displacement.NOTE 1: Insulating glass units qualified according to this specification are not necessarily suitable for structurally glazed applications. Factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications. For more information on the requirements for structural sealant glazing applications, refer to Specification C1369, Guide C1249, and Test Method C1265.1.9 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
79 条记录,每页 15 条,当前第 6 / 6 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页