3.1 The selection criteria is to be applied for uses of (1) new cable and (2) replacement cable.3.2 For the selection of new cable or the selection of replacement cable, this practice defines the choice criteria for conductor selection for cables in AWG (ASTM) or metric (IEC) sizes.1.1 This practice is intended as a guide to shipbuilders, shipowners, and design agents for use in the selection of conductor size for single conductor or multiple conductor cable sizes either in American Wire Gauge (AWG) or metric designations for commercial ship design and construction.1.2 The comparison chart of electrical conductor sizes shown in Table 1 presents a combined listing of stranded uncoated (plain) copper conductors in accordance with AWG Class B stranding (Specification B8) inch-pound units or international standard sizes of Class 2 IEC (Specification IEC 60228) metric units.1.3 As a precautionary caveat, some conductor sizes listed in Table 1 may exceed minimal size requirements of the U.S. Coast Guard, the American Bureau of Shipping, and IEEE STD 45 for specific applications.1.4 The values stated for ampacity and dc resistance are presented as maximum values and are provided for information only.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 515元 加购物车
1.1 These test methods cover the chemical analysis of gypsum and gypsum panel products, including gypsum ready-mixed plaster, gypsum wood-fibered plaster, and gypsum concrete.1.2 These test methods appear in the following order: Sections Preparation of Sample 4 Complete Procedure 5 – 16 Alternative Procedure for Analysis of Free Water in 17 Gypsum Using a Moisture Balance Alternative Procedure for Analysis of Combined Water in 18 Gypsum Using a Moisture Balance Alternative Procedure for Analysis of Organic Material 19 and Carbon Dioxide in Gypsum by High Temperature Weight Loss Alternative Procedure for Analysis for Calcium Sulfate by 20 Ammonium Acetate Method Alternative Procedure for Analysis for Sodium Chloride by 21 the Coulometric Method Determination of Sand in Set Plaster 22 Wood-fiber Content in Wood-fiber Gypsum Plaster 23 Optional Procedure for Analysis for Sodium by the Atomic 24 Absorption Method Optional Procedure for Analysis for Sodium by Flame 25 Photometry Determination of Orthorhombic Cyclooctasulfur (S8) in 26 Ggypsum Panel Products—General Provisions Determination of Orthorhombic Cyclooctasulfur (S8) in 27 Gypsum Panel Products by Gas Chromatograph Equipped with a Mass Spectrometer (GS/MS) Determination of Orthorhombic Cyclooctasulfur (S8) in 28 Gypsum Panel Products by Gas Chromatograph Equipped with an Electron Capture Detector (GC/ECD) Determination of Orthorhombic Cyclooctasulfur (S8) in 29 Gypsum Panel Products by High-performance Liquid Chromatograph Equipped with and Ultraviolet Detector (HPLC/UV) 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in these test methods.1.4 These text of this test method references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 646元 加购物车
1.1 This specification covers requirements for metric series, tapered roller bearings with a single row of rollers.1.2 Intended Use—The bearings covered in this specification are intended to be used in general industrial and vehicle applications where the operating temperature does not exceed 120 °C (250 °F).1.3 This specification contains many of the requirements of DS3225, which was originally developed by the Department of Defense and maintained by the Defense Supply Center in Richmond. The following government activity codes may be found in the Department of Defense, Standardization Directory SD-1.2Preparing Activity Custodians Review ActivitiesDLA-GS4 Army-AT Army-AV Navy-MC Navy –MC, SH Air Force-99 Air Force-84 Other-NS1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
定价: 590元 加购物车