This specification covers requirements and test methods for annular, corrugated profile wall polyethylene pipe and fittings with an interior liner. The pipe and blow-molded fittings shall be made of virgin PE plastic compound having a cell classification 435400C or 435400 and its carbon black content shall not exceed 4 %. Compounds used in the manufacture of rotationally molded fittings and couplings shall be virgin PE having a cell classification of 213320C or 213320E and its carbon black content shall not exceed 4%. On the other hand, compounds used in the manufacture of injection molded fittings and couplings shall be made of virgin PE plastic compound having a cell classification 414420C or 414420E and its carbon black content shall not exceed 4 %. Different tests and measurements shall be performed in order to determine the following properties of pipes: inside diameter, length, minimum inner-liner thickness, perforations, stiffness, flattening, and impact resistance. The pipe and fittings shall be homogeneous throughout and be as uniform as commercially practical in color, opacity, and density. The pipe walls shall be free of cracks, holes, blisters, voids, foreign inclusions, or other defects that are visible to the naked eye and that may affect the wall integrity. The ends shall be cut cleanly and squarely. Holes intentionally placed in perforated pipe are acceptable.1.1 This specification covers requirements and test methods for annular, corrugated profile wall polyethylene pipe and fittings with an interior liner. The nominal inside diameters covered are 300 mm to 1500 mm [12 in. to 60 in.].1.2 The requirements of this specification are intended to provide pipe and fittings for underground use for non-pressure gravity-flow storm sewer and subsurface drainage systems.NOTE 1: Pipe and fittings produced in accordance with this specification shall be installed in compliance with Practice D2321.1.3 This specification covers pipe and fittings with an interior liner using a corrugated exterior profile (Fig. 1).FIG. 1 Typical Annular Corrugated Pipe Profile1.4 The products manufactured under this standard use either virgin or recycled (post-industrial or post-consumer) materials in accordance with the requirements specified for each.1.5 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.6 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

4.1 Using the procedures and apparatus in Sections 8 and 9 and the manufacturer's instructions, pressure-tight joints as strong as the pipe itself can be made between manufacturer-recommended combinations of pipe and fittings. See Specification F1055 for performance requirements of polyethylene electrofusion fittings.1.1 This practice describes procedures for making joints suitable for pressure service with polyethylene (PE) pipe and fittings by means of electrofusion joining techniques in, but not limited to, a field environment. Other suitable electrofusion joining procedures are available from various sources including fitting manufacturers. This standard does not purport to address all possible electrofusion joining procedures, or to preclude the use of qualified procedures developed by other parties that have been proven to produce reliable electrofusion joints. (Note 1)NOTE 1: Reference to the manufacturer in this practice refers to the electrofusion fitting manufacturer.1.2 The parameters and procedure are applicable only to joining polyethylene pipe and fittings (Note 2) which are intended for PE fuel gas pipe per Specification D2513 and PE potable water, sewer and industrial pipe manufactured per Specification F714, Specification D3035, Specification F2619, and AWWA C901 and C906.NOTE 2: Commercially available materials classified with a thermoplastic pipe material designation code beginning with PE 14, PE 23, PE 24, PE 27, PE 33, PE 34, PE 36, and PE 46, and PE 47 in accordance with Specification D3350 and Terminology F412 are generally acceptable for electrofusion joining using this practice. Consult with the pipe or fitting manufacturer for specific compatibility information.1.3 Parts that are within the dimensional tolerances given in present ASTM specifications are required to produce sound joints between polyethylene pipe and fittings when using the joining techniques described in this practice.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The text of this practice references notes, footnotes, and appendices which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the practice.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers the general requirements and corresponding test methods for non-pressure (gravity flow) polyethylene (PE) pipes and fittings having interior liner with annular corrugated exterior wall profile, and whose inside diameters are 2 to 60 in. [50 to 1500 mm]. These pipes and fittings are suitable for underground use in subsurface and land drainage systems, which do not operate under surcharge pressure heads. Material requirements are specified for pipe and blow molded fittings, rotationally molded fittings and couplings, injection molded fittings and couplings, and rework materials. The resulting products shall be tested as appropriate, and shall conform to specified requirements for workmanship, dimension (inside diameter, length, minimum inner liner thickness, and perforations), stiffness, flattening resistance, impact resistance, and slow crack growth resistance of PE plastics without pigment.1.1 This specification covers requirements and test methods for annular corrugated profile wall polyethylene pipe and fittings with an interior liner. The inside diameters covered are 50 mm to 1500 mm [2 in. to 60 in.].1.2 The requirements of this specification are intended to provide non-pressure (gravity flow) pipe and fittings for underground use for subsurface and land drainage systems, which do not operate under surcharge pressure heads.NOTE 1: Pipe and fittings produced in accordance with this specification are be installed in compliance with Practice D2321 or Practice F449 based on diameter limitations within the respective standards.NOTE 2: Subsurface and land drainage systems pertain principally to non-municipal or private facilities for water table control, storm drainage and agricultural drainage applications. The products supplied under this specification are not intended for any sanitary sewer or municipal storm sewer applications.1.3 This specification covers pipe and fittings with an interior liner using an annular exterior corrugated profile (Fig. 1).1.4 This specification permits the use of recycled materials for pipe in accordance with the requirements in Section 5.1.5 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

Environmental performance test values for smooth-wall, coilable, medium density and high density polyethylene (MDPE and HDPE) conduit (duct) for preassembled wire and cable may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications. 1.1 These test methods cover procedures for determining the environmental performance properties of smooth-wall, coilable, medium-density and high-density polyethylene (MDPE and HDPE) conduit (duct) for preassembled wire and cable. 1.2 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

This specification covers requirements and test methods for annular, corrugated profile wall polyethylene pipe and fittings with an interior liner. The nominal inside diameters covered are 150 to 1500 mm [6 to 60 in.]. The requirements are intended to provide pipe and fittings suitable for underground use for non-pressure sanitary sewer systems. This specification also describes the materials and manufacture, general requirements (workmanship, dimensions and tolerance, pipe stiffness, pipe flattening, pipe impact strength, fittings and joining systems, slow crack growth resistance-pipe, structural design), test methods (referee testing, quality control testing), inspection, rejection and rehearing, certification, markings, packaging, and quality assurance.1.1 This specification covers requirements and test methods for annular, corrugated profile wall polyethylene pipe and fittings with an interior liner. The nominal inside diameters covered are 150 to 1500 mm [6 to 60 in.].1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use for non-pressure sanitary sewer systems. Pipe and fittings produced in accordance with this specification shall be installed in compliance with Practice D2321.1.3 This specification covers pipe and fittings with an interior liner using a corrugated exterior profile (Fig. 1).1.4 The products manufactured under this specification use either virgin or recycled (post-industrial or post-consumer) materials in accordance with the requirements specified for each.1.5 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.6 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

定价: 0元 / 折扣价: 0 加购物车

在线阅读 收 藏

4.1 This practice is to provide guidance for designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the rehabilitation of conduits. Modifications may be required depending on specific job conditions to establish a project specification. The manufacturer of the product should be consulted for design and installation information.1.1 This practice covers the requirements for the installation of deformed polyethylene (PE) liner for pipeline rehabilitation.1.2 This practice describes a method by which the PE liner may be installed with little or no excavation.1.3 This practice applies to the rehabilitation of 3 to 18 in. (76 to 457 mm) diameter pipe in terms of installation. The specifier determines what DR is used based on conditions of the specific application.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This specification covers polyethylene (PE 4710) electrofusion fittings for use with outside diameter-controlled crosslinked polyethylene (PEX) pipe, covered by Specifications F2788/F2788M, F2905/F2905M and F2968/F2968M. As stated in these PEX pipe standards, the PEX pipes joined to these PE 4710 electrofusion fittings have an HDB of 1250 psi or 1600 psi at 73 °F (23 °C) per Test Method D2837. Requirements for all metric-sized and inch-sized fittings for use with PEX pipe, made in accordance to these three pipe standards, are specified in Specification F2829/F2829M.1.2 The maximum allowable operating temperature of electrofusion fittings made in accordance with this standard is limited to the highest temperature at which the HDB of the PE 4710 has been determined. When joined to PEX pipe having a higher temperature HDB, the maximum use temperature for the PE/PEX joint is limited to the elevated temperature HDB rating of the PE material in the fittingNOTE 1: PEX and PE 4710 materials can have different elevated temperature ratings, and when joined together, the lower maximum elevated temperature rating will limit the maximum operating temperature. Per Table 1, the required PE 4710 material must have an HDB at 140 °F (60 °C), but may have an HDB at 180 °F (82 °C). PEX pipes generally have HDB ratings at 180 °F (82 °C) or 200 °F (93 °C) or both. When joined to PEX pipe, PE 4710 electrofusion fittings made in accordance with this standard may limit the maximum operating temperature to 140 °F (60 °C) where the PE 4710 material used does not have an optional higher temperature HDB rating.1.3 Requirements for materials, workmanship, and qualification testing performance are included. The PE electrofusion fitting manufacturer shall assure that fittings produced in accordance with this specification comply with all the requirements of this specification. If a PEX pipe manufacturer deems that their pipe is suitable for joining to polyethylene (PE) electrofusion fittings, the PEX pipe manufacturer shall qualify their PEX pipe by testing joints made with these PE electrofusion fittings, and assuring that the joints meet the performance requirements of this specification.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The following safety hazards caveat pertains only to the test method portion, Section 9, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

定价: 646元 / 折扣价: 550 加购物车

在线阅读 收 藏

1.1 This specification covers outside diameter controlled crosslinkable polyethylene (CX-PE) pipe produced in sizes DN 25 to 630 and NPS 1 to 24 in various dimension ratios. Included in this specification are requirements and test methods for the determination of the long-term hydrostatic strength, hydrostatic burst pressure, hydrostatic sustained pressure, UV weathering resistance, initial and ultimate degree of crosslinking, workmanship, and marking.1.2 This specification shall not be applied to crosslinked products, specifically PEX pipe or tubing.NOTE 1: CX-PE is a different designation separate from conventional PEX materials, specifically with regard to the crosslinking rate, installation, and commissioning processes.1.3 The pipe covered by this specification is intended for pressure and non-pressure applications. Fluids such as non-potable water, multi-phase mixed fluids, crude oils, gases, and chemical solutions containing some water are allowed to be transported in pipe made in accordance with this standard. Permissible operating temperatures for commissioned piping systems constructed from CX-PE pipe manufactured in accordance with this specification are ≤ 200 °F [93 °C].1.4 Pipe produced in accordance with this specification is intended to be crosslinked during or after installation. The procedures and practices to be used for the installation and crosslinking of the CX-PE pipe are outside the scope of this specification. Manufacturer’s recommendations for the commissioning of CX-PE pipe are used to ensure that the performance of the completed piping system meets design expectations.NOTE 2: The difference between pipes made in accordance with this specification and PEX pipes made in accordance with Specification F2905 is that the final crosslinking process is completed as part of installation and commissioning as opposed to crosslinking taking place in the manufacturing facility.1.5 This specification includes requirements to demonstrate a minimum level of performance in service.1.6 Joining of CX-PE pipes made in accordance with this specification is outside the scope of this specification. For guidance on the joining of CX-PE pipe consult Practice F3507 and manufacturer’s recommendations.1.7 This specification references notes, footnotes, and appendixes, which provide non-mandatory explanatory material. Excluding table footnotes which are mandatory, notes, footnotes and information in parentheses shall not be considered as requirements of this specification.1.8 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

This specification covers requirements for polyethylene (PE) pipe and fittings for normal residential and commercial roof drain systems. Material for pipe or fitting shall be made from PE virgin plastic as defined by hydrostatic design stresses and shall contain suitable stabilizers and antioxidants. Pipe and fitting requirements include pipe dimensions, fitting dimensions, chemical resistance, water absorption, system integrity, sealing rings, flattening, impact resistance, workmanship, finish, and appearance. Test methods include test conditions, chemical resistance, water absorption, hydrostatic pressure test, mechanical-joint pullout test, threads, flattening, and impact resistance. Quality and product marking shall also conform to the requirements of this specification.1.1 This specification covers requirements for polyethylene (PE) pipe and fittings for nonpressure roof drain systems.1.2 This specification covers pipe and fittings intended for normal residential and commercial uses and is not intended for use in unusual corrosive conditions.NOTE 1: Before installing pipe for waste disposal use, the approval of the cognizant building code authority shall be obtained as conditions not found in normal use or temperatures approaching 140 °F (60 °C) may be encountered.1.3 Pipe is produced in dimensions based on outside diameters of 32 mm (1.250 in.) and larger in accordance with Specification F714.1.4 The interchangeability of pipe and fittings made by different manufacturers is not addressed in this specification. Transition fittings for joining pipe and fittings of different manufacturers is provided for in this specification.1.5 Pipe and fittings are joined by the heat-fusion method, by the electrofusion method, or by using mechanical joints (excluding insert fittings) recommended by the manufacturer.1.6 In referee decisions, the SI units shall be used for metric-sized pipe and inch-pound units for pipe sized in the IPS system (ANSI B36.10). In all cases, the values given in parentheses are provided for information only.1.7 The following safety hazards caveat pertains only to the test method, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

1.1 This specification includes requirements, test methods, and materials for a polyethylene (PE) corrugated pipe with a smooth interior. The pipe consists of an outer corrugated wall connected to a smooth inner wall. Joints and fittings are included in this specification. 1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure applications such as sewers, conduit, and land drainage. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 The following safety hazards caveat pertains only to the test methods portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.