微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

This specification covers hubless cast iron soil pipe and fittings for use in gravity flow applications. These pipe and fittings are intended for non-pressure applications, as the selection of the proper size for sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage. The pipe and fittings shall be iron castings suitable for installation and service for sanitary, storm drain, waste, and vent piping applications. The pipe and fittings shall meet all applicable requirements and tests given in this specification. Tensile test and chemical test shall be made to conform to the requirements specified. The pipe and fittings shall be uniformly coated with a material suitable for the purpose that is adherent, not brittle, and without a tendency to scale.1.1 This specification covers hubless cast iron soil pipe and fittings for use in gravity flow applications. It establishes standards covering material, manufacture, mechanical and chemical properties, dimensions, coating, test methods, inspection, certification, and product marking for hubless cast iron soil pipe and fittings. These pipe and fittings are intended for non-pressure applications, as the selection of the proper size for sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage.1.2 The EDP/ASA numbers indicated in this section represent a Uniform Industry Code adopted by the American Supply Association (ASA). A group designation prefix, 022, is assigned to hubless products, followed by the four-digit identification assigned to individual items and a check digit. This system has been instituted to facilitate EDP control through distribution channels, and is to be used universally in ordering and specifying product items. Those items with no EDP numbers are either new, special, or transitory and will be assigned numbers on subsequent prints of this specification.1.3 This specification covers pipe and fittings of the following patterns and applies to any other patterns that conform with the dimensions found in Tables 1 and 2 and all other applicable requirements given in this specification.21.3.1 Lengths:  FiguresEDP/ASA Identification Numbersfor Hubless Pipe Fig. 110 ft (3.0 m) in sizes and 5 ft. (1.5 m)11/2 , 2, 3, 4, 5, 6, 8,10, 12, and 15 in. Fig. 1, Fig. 2Method of Specifying Fittings Fig. 31.3.2 Fittings: Quarter Bend Fig. 5Quarter Bend, Reducing Fig. 6Quarter Bend, with Side Opening Fig. 7Quarter Bend, with Heel Opening Fig. 8Quarter Bend, Tapped Fig. 9Quarter Bend, Double Fig. 10Quarter Bend, Long Fig. 11Short Sweep Fig. 12Long Sweep Fig. 13Long Sweep, Reducing Fig. 14Fifth Bend Fig. 15Sixth Bend Fig. 16Eighth Bend Fig. 17Eighth Bend, Long Fig. 18Sixteenth Bend Fig. 19Sanitary Tee Fig. 20Sanitary Tee with Side Opening Fig. 21Sanitary Tee with 2 in. Side Opening R or L/R and L Fig. 22Sanitary Tee, New Orleans Special with Side Opening Fig. 23Sanitary Tee with 45° Side Openings and New Orleans Fig. 24Sanitary Special Tee Tapped Fig. 25Sanitary Tapped Tee, Horizontal Twin Fig. 26Sanitary Tapped Tee, Double Vertical Fig. 27Y Branch Fig. 28Y Branch, Double Fig. 29Y Branch, Upright Fig. 30Upright Y Wide Center Florida Special Fig. 31Y Branch, Combination 1/8 Bend Fig. 32Y Branch, Combination 1/8 Bend Double Fig. 33Sanitary Cross Fig. 34Sanitary Cross with Side Opening Fig. 35Sanitary Cross, New Orleans, with Side Openings Fig. 36Sanitary Cross, New Orleans, with 45° Special and Regular Side Openings Fig. 37Sanitary Cross, Tapped Fig. 38Test Tee Fig. 39Tapped Extension Piece Fig. 40Increaser-Reducer Fig. 41Increaser-Reducer, Short Fig. 42Tapped Adapter Fig. 43Blind Plug Fig. 44Iron Body Cleanout, Tapped Fig. 45P Trap Fig. 46P Trap, Long Fig. 47P Trap, Deep Seal Fig. 48P Trap, with Primer Fig. 49P Trap, with Tapped Inlet Fig. 50Tapped Inlet, Double Fig. 51Modified Combination Wye and 1/8  Bend, Double Fig. 52Modified Combination Wye and 1/8  Bend, Double, Extended Fig. 53Two-Way Cleanout Fig. 54Twin Cleanout Fig. 55Closet Bend, Regular and Reducing Fig. 56Closet Flange Riser Fig. 57Tapping Bosses Fig. 58Double Sweep Sanitary Tee (Extended) Fig. 59Running Trap with Double Vents Fig. 60P Trap with Tapped or Hubless Side Inlet Fig. 61Vented Tub Wye Extended, Double Fig. 62Vented Tub Wye Extended Offset, Left or Right Fig. 63Vented Tub Wye Fig. 64Double Two-Way Cleanout Fig. 651.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.5 The committee with jurisdiction over this standard is aware of another comparable standard published by the Cast Iron Soil Pipe Institute, CISPI 301.NOTE 1: The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 983 加购物车

在线阅读 收 藏
307 条记录,每页 15 条,当前第 7 / 21 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页