微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 260元 / 折扣价: 221

在线阅读 收 藏

定价: 156元 / 折扣价: 133

在线阅读 收 藏

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

定价: 156元 / 折扣价: 133 加购物车

在线阅读 收 藏

5.1 The water-break test as described in this test method is rapid, nondestructive, and may be used for control and evaluation of processes for the removal of hydrophobic contaminants. A water-break “free” test is commonly used for in-process verification of the absence of surface contaminants on metal surfaces that may interfere with subsequent surface treatments such as priming, conversion coating, anodizing, plating, or adhesive bonding5.2 This test method is not quantitative and is typically restricted to applications where a go/no go evaluation of cleanliness will suffice.5.3 The test may also be used for the detection and control of hydrophobic contaminants in processing environments. For this application, a witness surface free of hydrophobic films is exposed to the environment and subsequently tested. The sensitivity of this test will vary with the level of airborne contaminant and the duration of exposure of the witness surface.5.4 For quantitative measurement of surface wetting, test methods that measure contact angle of a sessile drop of water or other test liquid may be used in some applications. Measurement methods based on contact angle are shown in Test Methods C813, D5946, and D7490; and Practice D7334.5.4.1 Devices for in situ measurement of contact angle are available. These devices are limited to a small measurement surface area and may not reflect the cleanliness condition of a larger surface. For larger surface areas, localized contact angle measurement, or other quantitative inspection, combined with water-break testing may be useful.5.5 For surfaces that cannot be immersed or doused with water, or where such immersion or dousing is impractical, such as previously coated large parts or assemblies, prior to the application of paints, primers or other organic coatings, Test Method F21 may be better suited for the evaluation of surface cleanliness than this test method.NOTE 2: This test method is not appropriate where line of sight evaluation is not feasible; or for assembled hardware where there is a risk for entrapment of water in faying surfaces or complex structures where it may not be effectively removed.1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing environments. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased.1.2 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM C1150-96 Standard Test Method for the Break-Off Number of Concrete (Withdrawn 2002) Withdrawn, No replacement 发布日期 :  1970-01-01 实施日期 : 

1.1 This test method covers determination of the break-off number of hardened concrete in test specimens or structures, by measuring the force required to cause failure of a pre-cast or drilled core specimen loaded as a cantilever. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏

4.1 Break depends on the fiber structure and on the relation between the grain and other strata of the leather. A fine break, or a grain pattern which shows many fine wrinkles when it is bent to form a concave surface, as it is in the vamp of a shoe, reflects favorably upon appearance and serviceability. A coarse break, on the other hand, where a few coarse wrinkles are formed on bending the grain to form a concave surface may indicate that the grain layer is separating from the corium or main stratum as in pipey leather. Shoes made from fine-break leather are more attractive and tend to wear longer than shoes made from coarse-break leather. (See MIL-STD 663 and the ALCA Journal).41.1 This test method covers the measurement of the break pattern of shoe upper leather using an arbitrary break scale. This test method does not apply to wet blue or wet white.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

1.1 This guide covers the preparation of a standard-size test sample and basic tests for physical property determinations of solid thermal break materials. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Note 1-There is no similar or equivalent ISO standard. 1.3 The following precautionary caveat pertains only to the test method portion, Sections 6 through 14, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

定价: 0元 / 折扣价: 0

在线阅读 收 藏
9 条记录,每页 15 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页