微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

5.1 Exposures to high concentrations of aerosolized fine and ultrafine non-fibrous metal particles, including manganese (Mn), chromium (Cr), and nickel (Ni) generated during processes that involve high energy such as welding or smelting, may elicit deleterious health effects. Animal and epidemiological studies have associated welding and related work processes with a wide range of adverse health effects, including upper respiratory effects (rhinitis and laryngitis), pulmonary effects (pneumonitis, chronic bronchitis, decreased pulmonary function), potential neurological disorders (manganese-induced Parkinsonism), and high lung cancer and pneumoconiosis death rates. Manganese has been associated with neurological diseases.5.2 Nanoparticles produced from metals, or their oxides and chalcogenides, have found many industrial uses. Examples of nanometals include silver (Ag), gold (Au), iron (Fe), copper (Cu), cadmium (Cd), zinc (Zn), platinum (Pt), and lead (Pd); examples of nanometal oxides include aluminium oxide (Al2O3), magnesium oxide (MgO), zirconium dioxide (ZrO2), cerium(IV) oxide (CeO2), titanium dioxide (TiO2), zinc oxide (ZnO), iron(III) oxide (Fe2O3), and tin(II) oxide (SnO); examples of nanometal sulfides include copper monosulfide (CuS), cadmium sulfide (CdS), zinc sulfide (ZnS), silver sulfide (AgS), tin sulfide (SnS), and many sulfides of Ni and cobalt (Co); examples of nanometal selenides include zinc selenide (ZnSe), cadmium selenide (CdSe), and mercury selenide (HgSe). Both the manufacture and use of these nanoparticles can result in particle inhalation, and consequent ill-effects. A stronger association has often been found between adverse health and cellular effects and inhalation of nanoparticles compared to larger particles of the same composition.5.3 Aerosol sampling methods generally specify the collection of workplace air samples using inhalable and related samplers. These exposure assessment methods, as well as the use of respirable and thoracic samplers (ISO 7708), are inadequate for measurements of nanoparticle exposure when paired with gravimetric analysis. Large particles (>1 μm) weigh substantially more than nanoparticles typical of fumes and, consequently, obscure the ability to detect nanoparticles through gravimetric filter sampling. Additionally, most size-selective samplers collect all particles in the fraction of aerosol that can penetrate into the respiratory tract. Particle deposition, which is governed by the principles of impaction, interception, and diffusion (ISO 13138), is typically overestimated by these samplers.5.4 There is a need to measure nanoparticle airborne concentrations apart from larger particles. An NRD sampler selectively collects nanoparticles in a manner similar to their typical deposition in the human respiratory tract. The constant motion of nanoparticles causes them to diffuse and potentially deposit in all regions of the respiratory tract, from the head airways to the deep alveolar region, as described by the ICRP (2). NRD samplers are designed to follow a nanoparticulate matter (NPM) deposition curve based on the ICRP model for deposition of particles smaller than 300 nm (the minimum in deposition for submicrometre particles) while removing the larger particles (1). Size-selective samplers (respirable, thoracic, and inhalable) mimic particle penetration rather than particle deposition. Many studies of welding fume have noted that size distribution of welding fume particles brackets the airways deposition minimum so that a substantial proportion of the fume is not deposited in the airways following inhalation (3-7). The use of an NRD sampler, however, approaches exposure assessment from a deposition estimation perspective (8) and provides a more relevant and physiological procedure for measuring actual hazards to workers (such as welders) posed by nanoparticle exposure. This knowledge is critical to the development of toxicological studies aimed at finding links between deposition of metal-containing nanoparticles and adverse health effects.5.5 Welding fumes are dominated by incidental nanoparticles (particles with any external dimension in the nanoscale), but also include larger particles generated by splatter. Current animal and epidemiological studies investigate exposure to welding fumes without differentiating between nanoparticles and larger particles. Welding fume nanoparticles have been found to induce more toxic effects at the cellular level and to generate more reactive oxygen species (ROS) activity when compared to larger particles.5.6 An NRD sampler was initially designed with nylon screens as the diffusion stage for the collection of nanoparticles (1), including welding fume (8, 9), although it was noted at the time that laboratory tests of this embodiment had not also included agglomerated particles, such as those which characterize welding fume. An additional collection mechanism, interception, was later found to play an important role as the sample collection of agglomerated nanoparticles progressed to higher loadings. Performance of the nylon screens for agglomerated particles was found to be affected by accumulated nanoparticle fraction loadings greater than 1 mg. The change in performance was accompanied by an increase in pressure drop across the screens to 14.3 kPa (57 in. of water) (5), which would cause many sampling pumps to fault. At the American Conference of Governmental Hygienists (ACGIH) Threshold Limit Value (TLV)5 for welding fume of 5 mg/m3, a one-hour sample at 2.5 L/min will collect 0.75 mg. Since the nanoparticle fraction of welding fume is typically less than half the total mass in air (3), the nylon screens are effective in sampling welding fume for one-hour or less as was borne out in field studies (9).5.7 A new diffusion stage substrate, polyurethane foam, has characteristics more closely resembling human airways (example, Ref (10)) and may be preferable for collecting agglomerated materials in higher loading scenarios (11). In addition, polyurethane foam does not contain titanium dioxide allowing this sampler to be used to assess nanoparticle titanium dioxide.5.8 The sampler with polyurethane foam has been shown to mimic the ICRP deposition curve closely when sampling spherical nanoparticles up to 100 nm diameter. Agglomerated particles collected in foam begin to show significant deviations from the simple curve as their size and shape factor increase (11). In Figure 3 of Ref (11), the curve modeling behavior of particles through foam is adjusted according to the dynamic shape factor of the aerosol and the sampler collection is shown to continue to match the modified curve at larger particle sizes. Since foam has proven to be a useful surrogate for lung deposition at larger particle sizes, it can be hypothesized that the adjusted foam model also will mimic the behavior of nanoparticle agglomerates in the lung. Enhanced deposition of larger agglomerates has been observed for agglomerated silica particles in human lung-casts (12) demonstrating that it may be necessary for an adjustment to the ICRP curve for agglomerates in this size range. However, until future research has identified a more precise adjustment to the ICRP deposition curve for agglomerated particles in the human airways the relationship of foam collection to human airways deposition remains a hypothesis.5.9 An accurate measurement of flow rate through an NRD sampler is required for experiments where sampling devices and filter materials are to be compared as to the size distribution aerosol they capture. Air flow rate affects the efficiency with which a sampler will capture a particular aerodynamic size of particles. Furthermore, air flow rate through a sampler may affect the distribution of aerosol particles captured on the filters and deposited on the sampler collection substrates and walls. To determine aerosol concentration from a mass of captured particles it is necessary to set and measure flow rates accurately.NOTE 2: Refer to Guide E1370 for guidance on the development of appropriate exposure assessment and measurement strategies.1.1 This practice describes specified apparatus and procedures for collection of non-fibrous airborne metal nanoparticles generated during work activities.1.2 Nanoparticle respiratory deposition (NRD) samplers are designed to follow a nanoparticulate matter (NPM) deposition curve based on the International Commission on Radiological Protection (ICRP) model for deposition of particles smaller than 300 nm (the minimum deposition for submicrometre particles) while removing the larger particles (1).21.3 This practice is applicable to personal and area sampling during work processes and situations where metal nanoparticles may be generated (for example, welding, smelting, shooting ranges).1.4 This practice is intended for use by professionals experienced in the use of devices for occupational air sampling (such as cyclone samplers).1.5 This practice is not applicable to the sampling of fibrous nanoparticles such as carbon nanotubes.1.6 Detailed operating instructions are not provided owing to differences among various makes and models of suitable devices and instruments. The user is expected to follow specific instructions provided by the manufacturers of particular items of equipment. This practice does not address comparative accuracy of different devices nor the precision between instruments of the same make and model.1.7 This practice contains notes that are explanatory and are not part of the mandatory requirements of the method.1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
ASTM D3353-18 Standard Test Methods for Fibrous-Insulated Magnet Wire Active 发布日期 :  1970-01-01 实施日期 : 

AbstractThese test methods cover the testing of fibrous-insulated electrical conductors, commonly referred to as magnet wire, which are used in electrical apparatus. The test methods are intended primarily for evaluation of the electrical insulating materials used. It is intended that these test methods be used, except where modified by individual specifications for particular applications. This elongation testing method covers the determination of the elongation of fibrous insulated magnet wire that results in a fracture of the conductor. The electrical resistance testing method covers the determination of the electrical resistance of fibrous insulated magnet wire conductors. The fibrous coverage testing method covers the determination of the quality of fibrous servings on round magnet wire or bare conductor. The measurement of dimensions test methods determine the dimensions of the bare or film insulated conductor and the fibrous-insulated magnet wire. The adhesion and flexibility test method covers the evaluation of the flexibility and adherence of varnished fibrous glass, and varnished or unvarnished fibrous polyester-glass insulating material on either bare conductor, or film-insulated magnet wire. The dielectric breakdown voltage test method covers the determination of the dielectric breakdown voltage in air of insulation on round, rectangular, and square wires at commercial power frequencies.1.1 These test methods cover the testing of fibrous-insulated electrical conductors, commonly referred to as magnet wire, which are used in electrical apparatus. The test methods are intended primarily for evaluation of the electrical insulating materials used. It is intended that these test methods be used, except where modified by individual specifications for particular applications.1.1.1 These test methods apply to those magnet wires that are fiber-covered and in which the substrate is bare conductor or is coated with an underlying insulating film as covered by Test Methods D1676. Fiber-covered wires are produced by serving helically or wrapping fibers or fibrous-tape insulation uniformly around the wire in single and multiple layers. The served or wrapped materials are bonded or not bonded to the underlying wire.1.2 The test methods appear in the following sections:Procedure SectionMeasurement of Dimensions 7Electrical Resistance of Conductors 5Elongation 4Adhesion and Flexibility 8Fibrous Coverage 6Dielectric Breakdown Voltage 91.3 This standard and IEC 60851 are similar if not equivalent in technical content.1.4 This standard and NEMA MW 1000 are similar if not equivalent in technical content.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See 8.4.1 and 9.4.1 for specific caution statements.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 Flexible fibrous glass insulation for metal buildings is evaluated in accordance with Test Method E84 to comply with building code requirements. This practice describes, in detail, specimen mounting procedures for Type I and Type II metal building insulation materials.5.2 The material to be tested shall be representative of the glass fiber blanket, facing and bonding adhesive used in actual field installations.5.3 The limitations for this procedure are those associated with Test Method E84.1.1 This practice describes a procedure for specimen preparation and mounting when testing Flexible Fibrous Glass Insulation for Metal Buildings to assess flame spread and smoke development as surface burning characteristics using Test Method E84.1.2 This practice applies to products described in Specification C991.1.3 This practice provides instructions for the testing of both un-faced insulation (Specification C991 Type I) and face insulation (Specification C991 Type II).1.4 This practice does not provide pass/fail criteria that can be used as a regulatory tool.1.5 Use the values stated in inch-pound units as the standard in referee decisions. The values in the SI system of units are given in parentheses, for information only; see IEEE/ASTM SI-10 for further details.1.6 This fire standard cannot be used to provide quantitative measures.1.7 Fire testing of products and materials is inherently hazardous and adequate safeguards for personnel and property shall be employed in conducting these tests. Fire testing involves hazardous materials, operations and equipment.1.8 This practice gives instructions on specimen preparation and mounting but the fire-test-response method shall be conducted in accordance with Test Method E84. See also Section 8 for information on operator safety.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

5.1 The water retention of the insulation can result in an increase in weight and a resultant potential degradation in the properties of the insulation.1.1 This test method covers a laboratory procedure for evaluating the water absorption potential of blanket insulation for aircraft, thereby providing a measure of potential weight increase due to water retention in an aircraft.1.2 The water repellency (or retention) characteristics of materials can be affected by conditions such as contamination or temperature of the water. Values obtained as a result of this test method does not adequately describe the water repellency characteristics of materials subject to these conditions.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
AS 2185-1978 Fibrous plaster products 被代替 发布日期 :  1970-01-01 实施日期 : 

定价: 260元 / 折扣价: 221 加购物车

在线阅读 收 藏

5.1 The tendency of the insulation toward wicking can result in an increase in weight and a resultant potential degradation in the properties of the insulation.1.1 This test method covers a laboratory procedure for evaluating the tendency of, aircraft type, fibrous glass blanket insulation to wick water.1.2 The wicking characteristics of materials can be affected by environmental conditions such as temperature and humidity. Values obtained as a result of this test method does not adequately describe the wicking characteristics of materials subject to conditions other than those indicated in the test method. (See Specification C800.)1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

This specification covers fibrous glass sound-absorbing board with a perforated fibrous glass cloth facing for sound reduction in ship spaces with high noise levels. It also measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of materials, products, or assemblies under actual fire conditions. The sound-absorbing board shall conform to the following performance requirements: density, surface flame spread and smoke generation properties, facing separation, and sound absorption coefficients.1.1 This specification covers fibrous glass sound-absorbing board with a perforated fibrous glass cloth facing for sound reduction in ship spaces with high noise levels. This specification is primarily for materials used on ships. Additional requirements, testing, and certification are required for use of this material aboard U.S. Coast Guard inspected vessels in the United States.1.2 Supplemental requirements and exceptions to the requirements discussed herein for ships of the U.S. Navy are included in Supplementary Requirements S1.1.3 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of materials, products, or assemblies under actual fire conditions.1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 Individual varnishes behave differently when applied to the same fibrous- or film-wrapped magnet wire when exposed to elevated temperatures. Likewise, a varnish does not always behave the same when applied to different types of fibrous or film-wrapped magnet wires and when exposed to elevated temperatures.FIG. 1 Jig for Forming Wire1.1 This test method covers the determination of thermal endurance of rectangular and square fibrous- or film-wrapped magnet wire coated with an insulating varnish.1.2 The values given in SI units are the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Section 5.NOTE 1: There is no similar or equivalent IEC Standard.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏

4.1 Inorganic fibrous thermal insulation can contain varying amounts of non-fibrous material. Non-fibrous material does not contribute to the insulating value of the insulation and therefore a procedure for determining that amount is desirable. Several specifications refer to shot content and percent (%) retained on various screen sizes determined by this test method.1.1 This test method covers a procedure for determining the non-fibrous content (shot) of man-made rock and slag mineral fiber insulation. The procedure covers a dry sieve analysis method to distinguish between fiberized and non-fiberized (shot) portions of a specimen of man-made rock and slag mineral fiber insulation specimen.1.2 This test method does not apply to rock or slag materials containing any components other than rock and slag mineral fiber, oil, and organic thermal setting binders. Products containing other types of fibers, inorganic binders, or refractory clays are excluded.NOTE 1: Industrial oils such as mineral or synthetic can be used to enhance the hydrophobic qualities and dust suppression.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 515元 / 折扣价: 438 加购物车

在线阅读 收 藏
9 条记录,每页 15 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页