微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

定价: 1132元 / 折扣价: 1008 加购物车

在线阅读 收 藏

定价: 2081元 / 折扣价: 1853 加购物车

在线阅读 收 藏

定价: 3038元 / 折扣价: 2704 加购物车

在线阅读 收 藏

定价: 3038元 / 折扣价: 2704 加购物车

在线阅读 收 藏

定价: 3204元 / 折扣价: 2852 加购物车

在线阅读 收 藏

5.1 This test method provides a means of measuring the sound isolation between the interior of a closed room and locations outside the room, and also the background noise levels at the locations outside the room. The results can be used to rate the degree of speech privacy, or to estimate the probability of speech being intelligible or audible at each receiving point.5.2 People speak at different levels and vary their voice level in reaction to room noise and other acoustical factors. Consequently it is not possible to say definitely whether a room is protected against eavesdropping. One can only assign a probability of being overheard. The owners or managers of the closed room under consideration must set criteria for this probability according to their specific goals and circumstances. The non-mandatory appendix gives an approach to setting criteria.1.1 This test method describes a test procedure for measuring the degree of speech privacy provided by a closed room, for conversations occurring within the room, and with potential eavesdroppers located outside the room.1.2 The degree of speech privacy measured by this method is that due to the sound insulation of the room structure—the walls, floor, ceiling and any other elements of the room boundaries—and to the background noise at listening positions outside the closed the room.1.3 Potential eavesdroppers are assumed to be unaided by electronic or electroacoustic equipment, and not touching the room boundaries. Determined efforts to eavesdrop are not addressed.1.4 The method may be applied to any enclosed room, whether specifically intended to be protected against eavesdropping or not.1.5 The method does not set criteria for adequate speech privacy. A non-mandatory appendix provides guidance on how the results of this test method may be used to estimate the probability of an eavesdropper being able to understand speech outside a closed room, and how to set criteria for such rooms.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

5.1 The speech privacy between locations in an open plan space is determined by the degree to which intruding speech sounds exceed the ambient sound pressure levels at the listener's ear; a classic signal-to-noise ratio situation.5.2 The sound pressure levels at the listener's ear from intruding speech depend upon:5.2.1 The individual vocal effort and orientation of the talker,5.2.2 The attenuation of speech signals due to distance or intervening barriers, and5.2.3 The reinforcement of speech signals due to reflections from surfaces such as the ceiling, furniture panels, light fixtures, walls, or windows.5.3 The ambient sound levels within a space often must be increased in order to mask intruding speech using an electronic sound masking system. However, in certain locations and in specific frequency ranges, the building mechanical, electrical and plumbing (MEP) equipment, and the heating, ventilating, or air conditioning equipment (HVAC) may increase ambient sound levels or add tonal noise components that may require mitigation before tuning the masking sound.5.4 The primary purpose of this test method is to assess the speech privacy for an average speech spectrum using the standard Articulation Index method. This requires measurement of the relevant acoustical characteristics discussed in 5.2 and 5.3 for a pair of locations and calculation of the Articulation Index using an average speech spectrum. The average speech spectrum is for male talkers speaking with normal voice effort. In specific cases such as designated quiet work zones for ‘focused work’ where administrative measures have been taken to reduce speech levels, a ‘casual’ voice spectrum should be used to calculate speech privacy, whereas in designated group work zones for ‘collaborative work’ where lively discussion is expected, a ‘raised’ voice spectrum should be used to calculate speech privacy.5.5 The Articulation Index ranges from a low value of 0.00, where speech is generally perceived to be unintelligible, to a high value of 1.00, where all individual spoken words can be understood. Caution should be exercised in interpreting the numerical AI results of this test method since the percentage of single words, phrases, and sentences understood will be different for the same AI value (5).5.6 This test method can be used to:5.6.1 Compare the relative speech privacy afforded between different locations within open plan spaces.5.6.2 Evaluate how changes in open plan components (barriers, furniture, ceilings, masking sound, or wall panels) affect speech privacy.5.6.3 Assess speech privacy objectively for correlation with subjective responses.5.7 This test method could be one element of a performance or acceptance test procedure. However, many additional items would need to be specified to allow the use of this test method for performance testing of an open plan environment, such as, the number of locations to be tested and method of selecting those locations, and the method of assessing the results. Specifying a numerical criterion in terms of the Articulation Index is also necessary for acceptance testing; however, the selection of such a criterion and permissible deviations should be undertaken with care in view of the present state-of-the-art as discussed in 5.5.1.1 This test method describes a means of objectively assessing speech privacy between locations in open plan spaces. This test method relies upon acoustical measurements, published information on speech levels, and standard methods for assessing speech communication. This test method does not measure the performance of individual open plan components which affect speech privacy; but rather, it assesses the privacy which results from a particular configuration of components (1, 2).21.2 This test method is intended to be a field test for the assessment of speech privacy in actual open plan spaces. However, this test method could be used in mock-up spaces and in environments arranged to simulate an open plan space.1.3 This test method is suitable for use in many open plan spaces including traditional open offices, focus areas, and collaboration spaces. In addition to office buildings, these types of spaces will also be found in healthcare buildings, institutional spaces, schools, etc. It is not directly applicable for measuring the speech privacy between open plan and enclosed spaces or between fully enclosed spaces.1.4 This test method relies upon the Articulation Index, which objectively predicts the intelligibility of speech. While both the Articulation Index and this test method can be expected to reliably predict speech privacy, neither predicts the specific effective speech privacy afforded to particular individual occupants.1.5 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590 加购物车

在线阅读 收 藏

定价: 0 加购物车

在线阅读 收 藏
27 条记录,每页 15 条,当前第 1 / 2 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页