微信公众号随时随地查标准

QQ交流1群(已满)

QQ群标准在线咨询2

QQ交流2群

购买标准后,可去我的标准下载或阅读

1. Scope and Object This clause of part 1 is applicable except as follows: 1.1 Scope Replacement: This standard applies to AUTOCLAVES and STERILIZERS, including those with an automatic loading and unloading system, which incorporate a CHAMBER

定价: 910元 / 折扣价: 774

在线阅读 收 藏

5.1 The Federal Occupational Safety and Health Administration, in 29 CFR 1910, designates that certain gases and vapors must not be present in workplace atmospheres at concentrations above specific values.5.2 This practice will provide a means for the determination of airborne concentrations of certain gases and vapors given in 29 CFR 1910.5.3 A partial list of chemicals for which this practice is applicable is presented in Annex A1.5.4 This practice also provides for the sampling of gaseous atmospheres to be used for process control or other purposes (2, 24-23).5.5 Advantages of the Detector Tube Method: 5.5.1 As the detector tube method requires no chemical analyzers, external reagents, etc., advance preparations are not needed; detector tubes are always ready for use.5.5.2 The detector tube method is well-suited for use at the work site because it is small, lightweight, and needs only a small sample volume to determine the concentration of gas or vapor in a sample.5.5.3 The operating procedures are simple.5.5.4 The results of measurements are available in just minutes, so fast action can be taken when needed.5.5.5 Where no electrical power source is required, detector tubes can be used even when flammable gases are present.5.5.6 Different types of detector tubes are available for different gases and measuring ranges, from 0.01 ppm to more than 10 %, depending on analyte and tube design, making the system flexible tor different sampling situations.1.1 This practice covers the detection and measurement of concentrations of toxic gases or vapors using detector tubes (1, 2).2 A list of some of the gases and vapors that can be detected by this practice and their measurement ranges are provided in Annex A1. This list is given as a guide and should be considered neither absolute nor complete.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏

5.1 The U.S. Occupational Safety and Health Administration (OSHA) in 29 CFR 1910.1000, Subpart Z, designates that certain gases and vapors present in work place atmospheres must be controlled so that their concentrations do not exceed specified limits. Other countries have similar regulations.5.2 This practice will provide a means for the measurement of airborne concentrations of certain gases and vapors listed in 29 CFR 1910.1000 and in other countries’ regulations.5.3 A partial list of chemicals for which this practice is applicable is presented in Appendix X1 with current National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) values (2) and typical measurement ranges for the selected chemicals as obtained from various manufacturer’s specifications. This list is for guidance purposes only; the user of this practice is responsible for determining the applicability of commercially available tubes to specific exposure limits.5.4 This practice may be used for either personal or area monitoring.1.1 This practice describes the detection and measurement of time weighted average (TWA) concentrations of toxic gases or vapors using length-of-stain colorimetric dosimeter tubes. A list of some of the gases and vapors that can be detected by this practice is provided in Appendix X1. This list is given as a guide and should be considered neither absolute nor complete.1.2 Length-of-stain colorimetric dosimeters work by diffusional sampling. The results are immediately available by visual observation; thus no auxiliary sampling, test, nor analysis equipment are needed. The dosimeters, therefore, are extremely simple to use and very cost effective.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

定价: 590元 / 折扣价: 502 加购物车

在线阅读 收 藏
3 条记录,每页 15 条,当前第 1 / 1 页 第一页 | 上一页 | 下一页 | 最末页  |     转到第   页