
【国外标准】 Standard Practice for Determining Load Resistance of Glass in Buildings
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice is used to determine the LR of specified glass types and constructions exposed to uniform lateral loads.5.2 Use of this practice assumes:5.2.1 The glass is free of edge damage and is properly glazed,5.2.2 The glass has not been subjected to abuse,5.2.3 The surface condition of the glass is typical of glass that has been in service for several years, and is weaker than freshly manufactured glass due to minor abrasions on exposed surfaces,5.2.4 The glass edge support system is sufficiently stiff to limit the lateral deflections of the supported glass edges to no more than 1/175 of their lengths. The specified design load shall be used for this calculation.5.2.5 The deflection of glass or support system, or both, shall not result in loss of glass edge support.NOTE 1: Glass deflections are to be reviewed. This practice does not address aesthetic issues caused by glass deflection.NOTE 2: This practice does not consider the effects of deflection on insulating glass unit seal performance.5.3 Many other factors shall be considered in glass type and thickness selection. These factors include but are not limited to: thermal stresses, spontaneous breakage of tempered glass, the effects of windborne debris, excessive deflections, behavior of glass fragments after breakage, blast, seismic effects, building movement, heat flow, edge bite, noise abatement, and potential post-breakage consequences. In addition, considerations set forth in building codes along with criteria presented in safety-glazing standards and site-specific concerns may control the ultimate glass type and thickness selection.5.4 For situations not specifically addressed in this standard, the design professional shall use engineering analysis and judgment to determine the LR of glass in buildings.1.1 This practice describes procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.1.2 This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of wind load, snow load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.1.3 This practice applies only to monolithic and laminated glass constructions of rectangular shape with continuous lateral support along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; (2) glass supported on two sides acts as a simply supported beam; and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass units with four-sided edge support.1.4 This practice does not apply to any form of wired, patterned, sandblasted, drilled, notched, or grooved glass. This practice does not apply to glass with surface or edge treatments that reduce the glass strength.1.5 This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and type of glass selected also depends upon a variety of other factors (see 5.3).1.6 Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides.1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.8 Appendix X2 lists the key variables used in calculating the mandatory type factors in Tables 1-3 and comments on their conservative values.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM E1300-16
标准名称:
Standard Practice for Determining Load Resistance of Glass in Buildings
英文名称:
Standard Practice for Determining Load Resistance of Glass in Buildings标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1038.16-1996 Coal and coke - Analysis and testing Assessment and reporting of results
- AS 1085.16-1995 Railway permanent way material Cast sleeper plates
- AS 1141.16-1995 Methods for sampling and testing aggregates Angularity number
- AS 1807.16-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level in cleanrooms
- ASTM F1983-23 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications
- ASTM F1985-99(2019)e1 Standard Specification for Pneumatic-Operated, Globe-Style, Control Valves
- ASTM F1988-99(2020) Standard Performance Requirements for Plastic Chaise Lounges, With or Without Moving Arms, With Adjustable Backs, for Outdoor Use
- ASTM F1989-05(2020) Standard Specification for Cooking Fire Suppression Blankets
- ASTM F2001-15(2022) Standard Guide for Vessel-Related Technical Information for Use in Developing an Electronic Database and Ship Safety Record
- ASTM F2003-02(2022) Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene After Gamma Irradiation in Air
- ASTM F2005-21 Standard Terminology for Nickel-Titanium Shape Memory Alloys
- ASTM F2011-02(2018) Standard Specification for Safety and Performance of Fun-Karts
- ASTM F2017-15(2022) Standard Guide for Database Structure of Electronic Data Interchange Between Ship Owner and Shipyard for Contract Administration
- ASTM F2019-22 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Pulled in Place Installation of Glass Reinforced Plastic Cured-in-Place (GRP-CIPP) Using the UV-Light Curing Method
- ASTM F2021-17(2022) Standard Guide for Design and Installation of Plastic Siphonic Roof Drainage Systems