【国外标准】 Standard Guide for Blood Cleaning Efficiency of Detergents and Washer-Disinfectors
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Significance—Dried blood represents a significant challenge to cleaning surgical instruments. The water-soluble components of blood are easily rendered insoluble when exposed to heat, chemical solutions, or time at room temperature. The water insoluble component of blood is fibrin built up during coagulation. These proteins bind quite readily to the surfaces of surgical instruments making them difficult to remove even with the aid of chemical cleaning agents. Instruments contaminated with blood residue after reprocessing represent a significant threat for infection to healthcare workers and patients. Healthcare facilities typically employ the use of automated instrument washers. These devices combine mechanical action along with chemical cleaning agents in a staged cleaning cycle designed to thoroughly clean surgical instruments. To function properly, these machines must be performing at targeted mechanical efficiency and deliver the correct chemical cleaning agents at the correct temperature, at the correct dosage for the correct period of time. Manufacturers of automated washers and manufacturers of cleaning detergent need to evaluate the performance of their products utilizing a surrogate for surgical instruments soiled with blood. The results of the performance testing will be used to improve product design and for validation of the performance of their product for various regulatory requirements.4.2 Use—The regular, periodic use of the blood soil test is a systemic challenge to the functioning of an automated washer. To properly challenge the cleaning device, the test must be analogous to the dried blood soil, to the stainless steel substrate, and to the physical barriers presented by surgical instruments. These physical barriers include the box lock, or pivot joint of a hinged instrument, the serrated tips, and crevices of surgical instruments. On the test coupon, the components of blood are similar to the state of dried blood on instruments. By utilizing a grooved stainless steel coupon, the substrate is similar to that of stainless steel instruments. By mounting the soiled coupon in a plastic holder the physical barriers represented by cracks and crevices of instruments (for example, box locks) are represented. Users are provided with an interpretation guide that aids them in interpreting results that are less than optimal. For instance, failure to remove the fibrin layer of blood soil (which is water insoluble) indicates a problem with the chemical cleaning agent(s). Failure to evenly remove a hemoglobin soil indicates a mechanical failure. Failure to remove any soil indicates either a catastrophic mechanical failure, or inappropriate settings for the initial rinse stage. As a standardized challenge, the test provides a reproducible means for the washer manufacturer and the detergent manufacturer to compare new designs and formulations to those existing within their own product line as well as those of others in the market. For the purpose of submitting their instructions for use, the test provides a means to validate the performance of their product with a device that is a surrogate for the devices their products will be used to clean in the practical setting. This validation testing can be used as part of any necessary documentation for regulatory filings and records.1.1 This guide is based on a standardized test soil correlating to coagulated blood suitable for screening tests and the evaluation of the cleaning efficiency of washer-disinfectors used for reprocessing of surgical instruments. This guide strictly deals with cleaning and does not describe any methods that are related to disinfection. See Referenced Documents D5343, D4008, D4265, D2960, and D3050 in Section 2 for additional information.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D7225-13(2019)e1
标准名称:
Standard Guide for Blood Cleaning Efficiency of Detergents and Washer-Disinfectors
英文名称:
Standard Guide for Blood Cleaning Efficiency of Detergents and Washer-Disinfectors标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM D7224-23 Standard Test Method for Determining Water Separation Characteristics of Kerosine-Type Aviation Turbine Fuels Containing Additives by Portable Separometer
- 下一篇: ASTM D7226-13(2023) Standard Test Method for Determining the Viscosity of Emulsified Asphalts Using a Rotational Paddle Viscometer
- 推荐标准
- AS 3785.7-1993/Amdt 1-1993 Underground mining - Shaft equipment - Sheaves
- AS 3785.7-2006/Amdt 1-2011 Underground mining - Shaft equipment Sheaves
- AS 3789.1-1991/Amdt 1-1992 Textiles for health care facilities and institutions - General ward linen
- AS 3857-1990/Amdt 1-1993 Heat exchangers - Tubeplates - Method of design
- AS 3862-1991/Amdt 1-1992 External fusion-bonded epoxy coating for steel pipes
- AS 3920.1-1993/Amdt 1-1995 Assurance of product quality - Pressure equipment manufacture
- AS 3947.3-1994/Amdt 1-1995 Low-voltage switchgear and controlgear - Switches, disconnectors, switch-disconnectors and fuse-combination units
- AS 3947.4.1-1995/Amdt 1-1995 Low-voltage switchgear and controlgear - Contactors and motor-starters - Electromechanical contactors and motor-starters
- AS 3947.5.2-1995/Amdt 1-1996 Low-voltage switchgear and controlgear - Control circuit devices and switching elements - Proximity switches
- AS 3962-2001/Amdt 1-2010 Guidelines for design of marinas
- AS 3972-1997/Amdt 1-2007 Portland and blended cements
- AS 4000-1997/Amdt 1-1999 General conditions of contract
- AS 4005.1 Supp 1-1992/Amdt 1-1995 Training and certification of recreational divers - Minimum entry-level SCUBA diving - Medical form for prospective recreational SCUBA divers (Supplement to AS 4005.1-1992)
- AS 4030.1-1992/Amdt 1-1995 Methods for the analysis of lead sulfide concentrates - Determination of lead content - Acid dissolution solvent extraction EDTA titration method
- AS 4031-1992/Amdt 1-1996 Non-reusable containers for the collection of sharp medical items used in health care areas