标准详细信息 去购物车结算

【国外标准】 Standard Guide for Assessment of Hard-on-Hard Articulation Total Hip Replacement and Hip Resurfacing Arthroplasty Devices

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

4.1 This document provides guidance for a range of assessments and evaluations to aid in preclinical research and device development of hard-on-hard total hip replacement and hip resurfacing devices used for the repair of musculoskeletal disorders.4.2 The user is encouraged to use appropriate ASTM International or ISO standards to conduct the physical, chemical, mechanical, biocompatibility, and preclinical tests on alloy fabricated forms, ceramic material samples, device components, or devices before assessment in an in vitro model.4.3 Studies to support regulatory submissions should conform to appropriate regulatory requirements and guidelines for the development of medical devices.4.4 Assessments with physical, chemical, mechanical, biocompatibility, and preclinical tests on hard-on-hard hip prosthesis components are not necessarily predictive of human results and therefore should be interpreted cautiously with respect to potential applicability to clinical conditions. Referenced metal-onmetal or ceramic-on-ceramic hip prosthesis publications can be found in the Bibliography section at the end of this guide for further review.1.1 This guide covers materials and design recommendations and general test methods for the chemical, mechanical, and preclinical assessment of implantable devices with hard-on-hard articulations intended to replace a hip joint. The provided guidance is intended to encompass both Total Hip Replacement (THR) devices with stems that extend or fix within the intramedullary canal as well as Hip Resurfacing Arthroplasty (HRA) wherein only the hip articulating surfaces are replaced. There has been long term clinical experience with metal-on-metal articulating components manufactured from cobalt-28 % chromium-6 % molybdenum (Co28Cr6Mo) alloy (Specifications F75, F799, or F1537) or high purity alumina (ISO 6474-1) and ceramic-on-ceramic articulating components manufactured from high purity alumina (ISO 6474-1) or alumina matrix composite ceramics (ISO 6474-2). There has also been some limited clinical experience with metal (Co28Cr6Mo) on alumina matrix composite ceramic articulating components. This guide has been created based on the current understanding derived from those clinical histories. Device articulating components manufactured from other metallic alloys, ceramics or with coated or elementally modified articulating surfaces could also be evaluated with this guide. However, such materials that do not have a history of clinical use may present different risks.1.2 This guide applies to the acetabular and femoral articulating components of hard-on-hard hip replacement devices. Acetabular components can be monoblock, or a modular component with a separate acetabular shell and acetabular liner. As stated above, articulating components have been made from Co28Cr6Mo for a metal-on-metal bearing; high purity alumina or alumina matrix composite ceramics for a ceramic-on-ceramic bearing; and Co28Cr6Mo and alumina matrix composite (ISO 6474-2) for a metal-on-ceramic bearing. Modular acetabular shells have to date been made from Ti-6Al-4V or Co28Cr6Mo. The shell is considered part of the acetabular component. Acetabular components may have external coating and/or porous structure intended for uncemented, press-fit or biological fixation; or, for use with bone cement.1.3 This standard is a summary of available specifications, test methods, practices, and guides from published standards or the scientific literature. Their clinical relevance is unproven. Most of the methods do not have an established precision and bias; therefore, their repeatability and reproducibility has not been established. As the clinical relevance of these methods have not been established, consequently, most do not have performance requirements. This document does not require that all the listed methodologies are always necessary to evaluate these implant systems provided justification for not using each unused method is provided. This document does not intend to prevent the use of new methodologies as they are developed.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM F3018-17

  • 标准名称:

    Standard Guide for Assessment of Hard-on-Hard Articulation Total Hip Replacement and Hip Resurfacing Arthroplasty Devices

  • 英文名称:

    Standard Guide for Assessment of Hard-on-Hard Articulation Total Hip Replacement and Hip Resurfacing Arthroplasty Devices
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

    11.040.40
  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    12 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    F04.22
  • 提出部门:

  • 发布部门:

  • 推荐标准
  • 国家标准计划