
【国外标准】 Standard Practice for Corrections Application for Non-Lethal Electric Security Fences
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Electric security fences, in view of their high-deterrent impact, are a safe method to reduce security costs or enhance existing security. They have broad applications for situations in which both minimum or maximum security are needed. They are deployed in a wide variety of environments and geographies. In particular, electric security fences are used to decrease the need for security guards and other security systems.4.2 This practice provides information to users and manufacturers of electric security fences, filling a void.4.3 International standards exist at IEC and BSI (see Section 2) that cover some aspects of these systems.4.4 A standard issued by Underwriters Laboratories (UL) (UL 69) covers electric fence controllers to be used on lighting or line circuits in accordance with NFPA 70. However, UL 69 covers, specifically, electric fence controllers used only for the control of animals. Its requirements cover portable and permanently mounted electric fence controllers with peak-discharge or sinusoidal-discharge output for indoor or outdoor use, including battery operated controllers intended to operate from battery circuits of 42.4 V or less, line-operated controllers intended to operate from circuits of 125 V or less, combination controllers intended to operate from either a battery or a line circuit, and photovoltaic module battery operated controllers. The scope states that the requirements of UL 69 do not cover electric fence controllers for the continuous (uninterrupted) current type or intermediate equipment, such as a converter, a rectifier, or the like, that is sometimes used between the primary source of supply and an electric fence controller and is investigated only as part of a complete controller. UL 69 also states that the requirements do not cover electric fence controllers for use with electrified security fences.4.5 In contrast to UL 69, this practice specifically addresses the use of electric security fences in detention and correctional facilities.NOTE 1: Extensive research on the safety of pulsed electrical devices, which are used in electric fence controllers, is found in work by Amit Nimunkar and John Webster.6 This research provides background on the safety of electric security fences and is of value to those wishing to understand the basic science behind these systems.4.6 Limitations of Electric Security Fences—It is likely that electric security fences are not appropriate for use in environments associated with juvenile, mental health, or other special populations.1.1 The purpose of this practice is to provide advice for the selection and use of non-lethal electric security fences to deter, detect, and delay an unauthorized breach of the perimeter.1.2 The intended applications of this practice are detention and correctional facilities.1.3 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. The tolerance on physical dimensions is ±10 % unless otherwise specified.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F3297-19
标准名称:
Standard Practice for Corrections Application for Non-Lethal Electric Security Fences
英文名称:
Standard Practice for Corrections Application for Non-Lethal Electric Security Fences标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM D7379/D7379M-08(2021) Standard Test Methods for Strength of Modified Bitumen Sheet Material Laps Using Cold Process Adhesive
- ASTM D7381-07(2021)e1 Standard Practice for Establishing Allowable Stresses for Round Timbers for Piles from Tests of Full-Size Material
- ASTM D7382-20 Standard Test Methods for Determination of Maximum Dry Unit Weight of Granular Soils Using a Vibrating Hammer
- ASTM D7385-21 Standard Guide for Estimating Carbon Saturation by Temperature Rise Upon Immersion
- ASTM D7387-20 Standard Test Method for Vibration Testing of Intermediate Bulk Containers (IBCs) Used for Shipping Liquid Hazardous Materials (Dangerous Goods)
- ASTM D7390-18e1 Standard Guide for Evaluating Asbestos in Dust on Surfaces by Comparison Between Two Environments
- ASTM D7391-20 Standard Test Method for Categorization and Quantification of Airborne Fungal Structures in an Inertial Impaction Sample by Optical Microscopy
- ASTM D7392-20 Standard Practice for PM Detector and Bag Leak Detector Manufacturers to Certify Conformance with Design and Performance Specifications for Cement Plants
- ASTM D7395-18(2023) Standard Test Method for Cone/Plate Viscosity at a 500 s-1 Shear Rate
- ASTM D7396-14(2020) Standard Guide for Preparation of New, Continuous Zinc-Coated (Galvanized) Steel Surfaces for Painting
- ASTM D7398-23 Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 °C to 615 °C by Gas Chromatography
- ASTM D7399-18 Standard Test Method for Determination of the Amount of Polypropylene in Polypropylene/Low Density Polyethylene Mixtures Using Infrared Spectrophotometry
- ASTM D7400/D7400M-19 Standard Test Methods for Downhole Seismic Testing
- ASTM D7402-09(2017) Standard Practice for Identifying Cationic Emulsified Asphalts
- ASTM D7403-19 Standard Test Method for Determination of Residue of Emulsified Asphalt by Low Temperature Vacuum Distillation