
【国外标准】 Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is used for determination of the carbon content of water from a variety of natural, domestic, and industrial sources. In its most common form, this test method is used to measure organic carbon as a means of monitoring organic impurities in high purity process water used in industries such as nuclear power, pharmaceutical, and electronics. 1.1 This test method covers the determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water in the range from 10 to 1000 μg/L of carbon. This method is for laboratory or grab sample applications and has been subjected to an interlaboratory study under the guidelines of D2777. Test Method D5997 can be used for on-line determinations. The test method utilizes persulfate or ultraviolet oxidation of organic carbon, or both coupled with a CO2 selective membrane to recover the CO2 into deionized water. The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample. Inorganic carbon is determined in a similar manner without the oxidation step. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane. The relationship between the conductivity measurement and carbon concentration is described by a set of chemometric equations for the chemical equilibrium of CO2, HCO3– , and H+, and the relationship between the ionic concentrations and the conductivity. The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances resulting in linear response of the method over the stated range of TOC. See Test Method D4519 for a discussion of the measurement of CO2 by conductivity. 1.2 This test method has the advantage of a very high sensitivity detector that allows very low detection levels on relatively small volumes of sample. Also, use of two measurement channels allows determination of CO2 in the sample independently of organic carbon. Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration, with minimal interferences. 1.3 This test method was used successfully with reagent water spiked with various organic materials. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices. 1.4 In addition to laboratory analyses, this test method may be adapted to on line monitoring. See Test Method D5997. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D6317-15
标准名称:
Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
英文名称:
Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 3730.15-1991 Guide to the properties of paints for buildings Primer - Latex - For metallic zinc surfaces
- AS 4276.15:2014 Water microbiology Examination for Vibrio cholerae
- AS 5013.15-2004 Food microbiology Microbiology - General guidance for enumeration of presumptive Escherichia coli - Most probable number technique
- AS IEC 60300.3.15-2011 Dependability management Application guide - Engineering of system dependability
- AS ISO 14520.15-2009 Gaseous fire-extinguishing systems - Physical properties and system design IG-541 extinguishant (ISO 14520-15:2005, MOD)
- AS/NZS 3200.2.15:1994 Approval and test specification - Medical electrical equipment Particular requirements for safety - Capacitor discharge X-ray generators
- AS/NZS 3350.2.15:1997 Safety of household and similar electrical appliances Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 1:1997 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 3:2001 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:1997/Amdt 4:2001 Safety of household and similar electrical appliances - Particular requirements - Appliances for heating liquids
- AS/NZS 3350.2.15:2002/Amdt 1:2003 Safety of household and similar electrical appliances Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995, MOD)
- AS/NZS 3350.2.15:2002/Amdt 2:2003 Safety of household and similar electrical appliances - Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995, MOD)
- AS/NZS 3350.2.15:2002/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements for appliances for heating liquids (IEC 60335-2-15:1995)
- AS/NZS 3750.15:1998 (R2013) Paints for steel structures Inorganic zinc silicate paint
- AS/NZS 4456.15:1997 Masonry units and segmental pavers - Methods of test Determining lateral modulus of rupture