标准详细信息 去购物车结算

【国外标准】 Standard Test Method for Measuring Net Heat Flux Using a Water-Cooled Calorimeter

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

5.1 The purpose of this test method is to measure the net heat flux to a water-cooled surface for purposes of calibration of the thermal environment into which test specimens are placed for evaluation. The measured net heat flux is one of the important parameters for correlating the behavior of materials. If the calorimeter and holder size, shape, and surface finish are identical to that of the test specimen, the measured net heat flux to the calorimeter is presumed to be the same as that to the sample's heated surface. If the calorimeter configuration (holder size, shape, finish, etc.) is not identical to that of the test specimen, then the measurement results may need to be modified to account for those differences. See Appendix X1.5.2 The water-cooled calorimeter is one of several calorimeter concepts used to measure net heat flux. The prime drawback is its long response time, that is, the time required to achieve steady-state operation. To calculate energy added to the coolant water, accurate measurements of the rise in coolant temperature are needed, all energy losses should be minimized, and steady-state conditions must exist both in the thermal environment and fluid flow of the calorimeter.5.3 Regardless of the source of energy input to the water-cooled calorimeter surface (radiative, convective, or combinations thereof) the measurement is averaged over the surface-active area of the calorimeter. If the water-cooled calorimeter is used to measure only radiative flux or combined convective-radiative net heat flux rates, then the surface reflectivity of the calorimeter shall be measured over the wavelength region of interest (depending on the source of radiant energy). If nonuniformities exist in the gas stream, a large surface area water-cooled calorimeter would tend to smooth or average any variations. Consequently, it is advisable that the size of the calorimeter be limited to relatively small surface areas and applied to where the net heat flux is uniform. Where large samples are tested, it is recommended that a number of smaller diameter water-cooled calorimeters be used (rather than one large unit). These shall be located across the heated surface such that a net heat flux distribution can be described. With this, a more detailed net heat flux measurement can be applied to the specimen test and more information can be deduced from the test.1.1 This test method covers the measurement of a steady net heat flux to a given water-cooled surface by means of a system energy balance.1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM E422-22

  • 标准名称:

    Standard Test Method for Measuring Net Heat Flux Using a Water-Cooled Calorimeter

  • 英文名称:

    Standard Test Method for Measuring Net Heat Flux Using a Water-Cooled Calorimeter
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

    17.200.10
  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    8 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    E21.08
  • 提出部门:

  • 发布部门:

  • 推荐标准
  • 国家标准计划