【国外标准】 Standard Test Method for Assessing the Microbial Detoxification of Chemically Contaminated Water and Soil Using a Toxicity Test with a Luminescent Marine Bacterium (Withdrawn 2014)
本网站 发布时间:
2024-02-28
- ASTM D5660-96(2009)
- Withdrawn, No replacement
- 定价: 0元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This test method provides a rapid means of determining the acute toxicity of an aqueous waste, or waste extract, prior to and following biological treatment, and contributes to assessing the potential biodegradability of the waste (see 1.1, 1.2, and Note 1). The change in toxicity to the marine bacterium P. phosphoreum with respect to time may serve as an indication of the biodegradation potential. Sample analyses are usually obtained in 45 to 60 min, with as little as 5 mL of sample required (5). Samples with high suspended solids concentrations may test nontoxic to the bacteria, while still exhibiting significant toxicity to freshwater organisms, due to those suspended solids. The absorbance correction procedure included in this test method allows for the analysis of highly colored lightabsorbing samples, by providing a means for mathematically adjusting the light output readings to account for light lost due to absorption. 1.1 This test method (1) covers a procedure for the rapid evaluation of the toxicity of wastewaters and aqueous extracts from contaminated soils and sediments, to the luminescent marine bacterium Photobacterium phosphoreum, prior to and following biological treatment. This test method is meant for use as a means to assess samples resulting from biotreatability studies. Sensitivity data for P. phosphoreum to over 1300 chemicals have been reported in the literature (2). Some of the publications are very relevant to this test method (3). The data obtained from this test method, when combined with respirometry, total organic carbon (TOC), biochemical oxygen demand (BOD), chemical oxygen demand (COD), or spectrophotometric data, can assist in the determination of the degree of biodegradability of a contaminant in water, soil, or sediment (3). The percentage difference between the IC20 of treated and untreated sample is used to assess the progress of detoxification. 1.2 This test method is applicable to the evaluation of the toxicity (to a specific microbe) and its implication on the biodegradation of aqueous samples from laboratory research bio-reactors (liquid or soil), pilot-plant biological treatment systems, full-scale biological treatment systems, and land application processes (see Notes 1 and 2). Note 1—If the biologically treated material is to be discharged in such a manner as to potentially impact surface waters and ground water, or both, then the user must consult appropriate regulatory guidance documents to determine the proper test species for evaluating potential environmental impact (4). Correlations between data concerning reduction in toxicity produced by this test method and by procedures for acute or short-term chronic toxicity tests, or both, utilizing invertebrates and fish (see Guides E729 and E1192E729E1192), should be established, wherever possible. Note 2—Color (especially red and brown), turbidity, and suspended solids interfere with this test method by absorbing or reflecting light. In these situations data are corrected for these effects by use of an absorbance correction procedure included in this test method (see 5.3, 6.1, and 6.2). 1.3 The results of this test method are reported in terms of an inhibitory concentration (IC), which is the calculated concentration of sample required to produce a specific quantitative and qualitative inhibition. The inhibition measured is the quantitative reduction in light output of luminescent marine bacteria (that is, IC20 represents the calculated concentration of sample that would produce a 20 % reduction in the light output of exposed bacteria over a specified time). 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.
标准号:
ASTM D5660-96(2009)
标准名称:
Standard Test Method for Assessing the Microbial Detoxification of Chemically Contaminated Water and Soil Using a Toxicity Test with a Luminescent Marine Bacterium (Withdrawn 2014)
英文名称:
Standard Test Method for Assessing the Microbial Detoxification of Chemically Contaminated Water and Soil Using a Toxicity Test with a Luminescent Marine Bacterium (Withdrawn 2014)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E1815-18(2023) Standard Test Method for Classification of Film Systems for Industrial Radiography
- ASTM E1820-23b Standard Test Method for Measurement of Fracture Toughness
- ASTM E1822-21 Standard Test Method for Fire Testing of Stacked Chairs
- ASTM E1823-23 Standard Terminology Relating to Fatigue and Fracture Testing
- ASTM E1826-23 Standard Specification for Low Volatile Organic Compound (VOC) Corrosion-Inhibiting Adhesive Primer for Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels
- ASTM E1827-22 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
- ASTM E1829-14(2020) Standard Guide for Handling Specimens Prior to Surface Analysis
- ASTM E1832-08(2017) Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer
- ASTM E1834-18 Standard Test Method for Analysis of Nickel Alloys by Graphite Furnace Atomic Absorption Spectrometry
- ASTM E1835-14(2022) Standard Test Method for Analysis of Nickel Alloys by Flame Atomic Absorption Spectrometry
- ASTM E1845-23 Standard Practice for Calculating Pavement Macrotexture Mean Profile Depth
- ASTM E1851-21 Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
- ASTM E1854-19 Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts
- ASTM E1856-13(2021) Standard Guide for Evaluating Computerized Data Acquisition Systems Used to Acquire Data from Universal Testing Machines
- ASTM E1857-97(2021) Standard Guide for Selection of Cleaning Techniques for Masonry, Concrete, and Stucco Surfaces