
【国外标准】 Standard Test Methods for Linear Density of Textile Fibers
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Option A for bundle weighing of Test Method D1577 is used in the trade for acceptance testing of commercial shipments. Option B for single-fiber weighing and Option C for the vibroscope may be used for acceptance testing (see Section 37); however, caution is advised when using Option B or Option C because between-laboratory precision information is incomplete. Comparative tests as directed in 4.1.1 may be advisable.4.1.1 In case of dispute arising from differences in reported test results when using Test Method D1577 for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of samples that are as homogeneous as possible and that are from a lot of material of the type in question. These samples should then be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using the appropriate statistical analysis and a probability level chosen by the two parties before testing is begun. If a bias is found, either the cause must be found and corrected or the purchaser and the supplier must agree to interpret future test results for that material with consideration to the known bias.4.2 Option A for bundle weighing is generally considered to be the referee procedure for acceptance testing.4.3 Option A is not recommended for measurement of linear density of blends of production fibers having different nominal linear densities.4.4 The accuracy of the linear density values obtained by Options A and B is dependent upon the accuracy with which the fibers can be cut and weighed.NOTE 2: On short staple fiber, an accuracy in cutting of 1.0 % is difficult to obtain. This problem is further complicated if crimp is present in the fibers.4.4.1 The accuracy of weighing can be controlled by the number of fibers composing the bundle. However, with short fiber of low linear density the number of fibers to be counted becomes prohibitive unless the bundle mass is kept low.4.5 Options A and B are fundamental procedures which are used to standardize the vibroscope equipment used in Options C1 and C2.4.6 Test Method Options B and C are most useful for the measurement of linear density of single fibers when further tests upon the same test specimen are required, for example, tension tests and adjustment of the data obtained for the linear density of the test specimen. These options offer advantages in accuracy and ease of operations over calculation from specific gravity and microscopically measured cross-sectional area.4.7 Additional information specific to Option C is in Section 26.1.1 These test methods cover the measurement of mass per unit length (linear density) of textile fibers and filaments. Direct weighing and vibroscope procedures with modifications for crimped and uncrimped fibers are included. The options and sections are listed below. Option Sections A—Fiber Bundle Weighing 7 – 15 B—Single-Fiber Weighing 16 – 23 C—Vibroscope, General 24 – 30 35 and 36 C1—Uncrimped Fibers 31 and 32 C2—Crimped Fibers 33 and 34 Precision and Bias 37 and 38NOTE 1: For linear density of short lengths of yarn, refer to Test Method D1059. For cotton linear density, refer to Test Methods D1769 and D2480. For measurement of wool diameter, refer to Test Methods D1282, D2130, and D3510.1.2 The crimp, taper, and cross-sectional shape of the fiber may influence the linear density measured by single-fiber weighing and vibroscope.1.3 These test methods measure the linear density of fibers with moisture in equilibrium with the standard atmosphere for testing textiles. The fiber moisture under these conditions is not necessarily the same as the commercial moisture regain for the fibers.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D1577-07(2018)
标准名称:
Standard Test Methods for Linear Density of Textile Fibers
英文名称:
Standard Test Methods for Linear Density of Textile Fibers标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM D7379/D7379M-08(2021) Standard Test Methods for Strength of Modified Bitumen Sheet Material Laps Using Cold Process Adhesive
- ASTM D7381-07(2021)e1 Standard Practice for Establishing Allowable Stresses for Round Timbers for Piles from Tests of Full-Size Material
- ASTM D7382-20 Standard Test Methods for Determination of Maximum Dry Unit Weight of Granular Soils Using a Vibrating Hammer
- ASTM D7385-21 Standard Guide for Estimating Carbon Saturation by Temperature Rise Upon Immersion
- ASTM D7387-20 Standard Test Method for Vibration Testing of Intermediate Bulk Containers (IBCs) Used for Shipping Liquid Hazardous Materials (Dangerous Goods)
- ASTM D7390-18e1 Standard Guide for Evaluating Asbestos in Dust on Surfaces by Comparison Between Two Environments
- ASTM D7391-20 Standard Test Method for Categorization and Quantification of Airborne Fungal Structures in an Inertial Impaction Sample by Optical Microscopy
- ASTM D7392-20 Standard Practice for PM Detector and Bag Leak Detector Manufacturers to Certify Conformance with Design and Performance Specifications for Cement Plants
- ASTM D7395-18(2023) Standard Test Method for Cone/Plate Viscosity at a 500 s-1 Shear Rate
- ASTM D7396-14(2020) Standard Guide for Preparation of New, Continuous Zinc-Coated (Galvanized) Steel Surfaces for Painting
- ASTM D7398-23 Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 °C to 615 °C by Gas Chromatography
- ASTM D7399-18 Standard Test Method for Determination of the Amount of Polypropylene in Polypropylene/Low Density Polyethylene Mixtures Using Infrared Spectrophotometry
- ASTM D7400/D7400M-19 Standard Test Methods for Downhole Seismic Testing
- ASTM D7402-09(2017) Standard Practice for Identifying Cationic Emulsified Asphalts
- ASTM D7403-19 Standard Test Method for Determination of Residue of Emulsified Asphalt by Low Temperature Vacuum Distillation